SearcharxivSearch

arXiv subjects

I. Mandic

Publications and source records attributed to I. Mandic.

7 recordsLinked to original sources

The study of gamma-radiation induced displacement damage in $n^+$-in-$p$ silicon diodes

The bulk damage of $p$-type silicon sensors caused by gamma irradiation with high total ionizing doses has been investigated. The study was carried out on different types of $n^+$-in-$p$ silicon diodes with different oxygen concentrations and silicon bulk resistivities. The Secondary-Ion Mass Spectrometry technique was used to determine the relative concentration of oxygen in the individual samples. The measured diodes were irradiated by a $^{60}$Co gamma source to total ionizing doses ranging from 0.50 up to 8.28 MGy, and annealed for 80 minutes at 60{\deg}C. The main goal of the study was to characterize the gamma-radiation induced displacement damage by measuring IV and CV characteristics, and the evolution of the full depletion voltage with the total ionizing dose. The Transient Current Technique was used to verify the full depletion voltage and to extract the electric field distribution and the sign of the space charge in the silicon diodes irradiated to the lowest and the highest delivered total ionizing doses. The results show a linear increase of the bulk leakage current with the total ionizing dose, with the damage coefficient being dependent on initial resistivity and oxygen concentration of the silicon diode. The effective doping concentration and full depletion voltage decrease significantly with an increasing total ionizing dose, before starting to increase again at a specific dose. We assume that the initial decrease in the effective doping concentration is caused by the effect of acceptor removal. An additional notable finding of this study is that the bulk leakage current and CV characteristics of the gamma-irradiated diodes do not show any evidence of an annealing effect.

hep-ex

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13~$n_{eq}/cm^2$ fluence over the lifetime of the experiment.

physics.ins-det

Evolution of the electrical characteristics of the ATLAS18 ITk strip sensors with HL-LHC radiation exposure range

The objective of the study is to evaluate the evolution of the performance of the new ATLAS Inner-Tracker (ITk) strip sensors as a function of radiation exposure, to ensure the proper operation of the upgraded detector during the lifetime of the High-Luminosity Large Hadron Collider (HL-LHC). Full-size ATLAS ITk Barrel Short-Strip (SS) sensors with final layout design, ATLAS18SS, have been irradiated with neutrons and gammas, to confirm the results obtained with prototypes and miniature sensors during the development phase. The irradiations cover a wide range of fluences and doses that ITk will experience, going from 1e13 neq/cm2 and 0.49 Mrad, to 1.6e15 neq/cm2 and 80 Mrad. The split irradiation enables a proper combination of fluence and dose values of the HL-LHC, including a 1.5 safety factor. A complete electrical characterization of the key sensor parameters before and after irradiation is presented, studying the leakage current, bulk capacitance, single-strip and inter-strip characteristics. The results confirm the fulfilment of the ATLAS specifications throughout the whole experiment. The study of a wide range of fluences and doses also allows to obtain detailed results, such as the frequency dependence of the bulk capacitance measurements for highly irradiated sensors, or the evolution of the punch-through protection and inter-strip resistance with radiation.

physics.ins-det

Annealing effects on operation of thin Low Gain Avalanche Detectors

Several thin Low Gain Avalanche Detectors from Hamamatsu Photonics were irradiated with neutrons to different equivalent fluences up to $Φ_{eq}=3\cdot10^{15}$ cm$^{-2}$. After the irradiation they were annealed at 60$^\circ$C in steps to times $>20000$ minutes. Their properties, mainly full depletion voltage, gain layer depletion voltage, generation and leakage current, as well as their performance in terms of collected charge and time resolution, were determined between the steps. It was found that the effect of annealing on timing resolution and collected charge is not very large and mainly occurs within the first few tens of minutes. It is a consequence of active initial acceptor concentration decrease in the gain layer with time, where changes of around 10\% were observed. For any relevant annealing times for detector operation the changes of effective doping concentration in the bulk negligibly influences the performance of the device, due to their small thickness and required high bias voltage operation. At very long annealing times the increase of the effective doping concentration in the bulk leads to a significant increase of the electric field in the gain layer and, by that, to the increase of gain at given voltage. The leakage current decreases in accordance with generation current annealing.

physics.ins-det

Determination of the electric field in highly-irradiated silicon sensors using edge-TCT measurements

A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are investigated by simulations of non-irradiated $n^+p$ pad sensors and by the analysis of edge-TCT data from non-irradiated $n^+p$ strip-detectors. The method is then used to determine the position dependent electric field and charge density in $n^+p$ strip detectors irradiated by reactor neutrons to fluences between 1 and $10 \times 10^{15}$ cm$^{-2}$ for forward-bias voltages between 25 V and up to 550 V and for reverse-bias voltages between 50 V and 800 V. In all cases the velocity profiles are well described. The electric fields and charge densities determined provide quantitative insights into the effects of radiation damage for silicon sensors by reactor neutrons.

physics.ins-det

Radiation Hardness of Thin Low Gain Avalanche Detectors

Low Gain Avalanche Detectors (LGAD) are based on a n++-p+-p-p++ structure where an appropriate doping of the multiplication layer (p+) leads to high enough electric fields for impact ionization. Gain factors of few tens in charge significantly improve the resolution of timing measurements, particularly for thin detectors, where the timing performance was shown to be limited by Landau fluctuations. The main obstacle for their operation is the decrease of gain with irradiation, attributed to effective acceptor removal in the gain layer. Sets of thin sensors were produced by two different producers on different substrates, with different gain layer doping profiles and thicknesses (45, 50 and 80 um). Their performance in terms of gain/collected charge and leakage current was compared before and after irradiation with neutrons and pions up to the equivalent fluences of 5e15 cm-2. Transient Current Technique and charge collection measurements with LHC speed electronics were employed to characterize the detectors. The thin LGAD sensors were shown to perform much better than sensors of standard thickness (~300 um) and offer larger charge collection with respect to detectors without gain layer for fluences <2e15 cm-2. Larger initial gain prolongs the beneficial performance of LGADs. Pions were found to be more damaging than neutrons at the same equivalent fluence, while no significant difference was found between different producers. At very high fluences and bias voltages the gain appears due to deep acceptors in the bulk, hence also in thin standard detectors.

physics.ins-det

Beam test results of a 16 ps timing system based on ultra-fast silicon detectors

In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 μm) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.

physics.ins-det