SearcharxivSearch

arXiv subjects

I. Martinez

Publications and source records attributed to I. Martinez.

3 recordsLinked to original sources

Validation and demonstration of the AEFC as a practical safeguards tool for inventory verification

The Advanced Experimental Fuel Counter (AEFC) is a nondestructive assay (NDA) instrument designed to determine the residual fissile mass in irradiated fuel assemblies for safeguards verification purposes. This is done by actively interrogating an assembly with a neutron source and measuring the total (Singles) and correlated (Doubles) neutron count rates resulting from induced fissions in the irradiated nuclear fuel and relating those rates to the residual fissile mass using calibration curves. Comprehensive NDA measurements of the irradiated fuel inventory at Israeli Research Reactor 1 (IRR-1) were taken with the AEFC to validate a set of previously developed calibration curves. During the campaign, measurements were acquired of 32 standard fuel assemblies and three control assemblies in just nine days. This is a significant majority of the research reactor's irradiated fuel inventory and the largest data set gathered by the AEFC to date. Many of the fuel assemblies measured during the campaign had much shorter cooling times than those assemblies previously measured with the instrument. Calibration curves developed from previous AEFC deployments were used to determine the residual U-235 mass in the measured standard fuel assemblies. The results of the campaign demonstrated that the AEFC can be used to estimate the U-235 mass remaining in a large number of irradiated fuel assemblies with 1%-5% uncertainty in a reasonable amount of time despite operating in a high dose environment.

physics.ins-det

Shot noise in magnetic tunneling structures with two-level quantum dots

We analyze shot noise in a magnetic tunnel junction with a two-level quantum dot attached to the magnetic electrodes. The considerations are limited to the case when some transport channels are suppressed at low temperatures. Coupling of the two dot's levels to the electrodes are assumed to be generally different and also spin-dependent. To calculate the shot noise we apply the approach based on the full counting statistics. The approach is used to account for experimental data obtained in magnetic tunnel junctions with organic barriers. The experimentally observed Fano factors correspond to the super-Poissonian statistics, and also depend on relative orientation of the electrodes' magnetic moments. We have also calculated the corresponding spin shot noise, which is associated with fluctuations of spin current.

cond-mat.mes-hall

Transient lateral photovoltaic effect in patterned metal-oxide-semiconductor films

The time dependent transient lateral photovoltaic effect has been studied with us time resolution and with chopping frequencies in the kHz range, in lithographically patterned 21 nm thick, 5, 10 and 20 um wide and 1500 um long Co lines grown over naturally passivated p-type Si (100). We have observed a nearly linear dependence of the transitorial response with the laser spot position. A transitorial response with a sign change in the laser-off stage has been corroborated by numerical simulations. A qualitative explanation suggests a modification of the drift-diffusion model by including the in uence of a local inductance. Our findings indicate that the microstructuring of position sensitive detectors could improve their space-time resolution.

physics.optics