SearcharxivSearch

arXiv subjects

I. Ravinovich

Publications and source records attributed to I. Ravinovich.

12 recordsLinked to original sources

Performance of resistive MPGDs with pad readout coupled to VMM3a ASIC

We present a comparative study of three resistive Micro-Pattern Gaseous Detector (MPGD) technologies - Micromegas, RPWELL, and $\mu\mathrm{-RWELL}$ - with VMM3a based readout, using relativistic muons and pions. The Micromegas and the RPWELL were operated in $\mathrm{Ar/CO_2/iC_4H_{10}}$ gas mixture, while the $\mu\mathrm{-RWELL}$ in $\mathrm{Ar/CO_2/CF_4}$ (greenhouse gas containing mixture). All detectors operated stably exceeding 96% efficiency. The usage of continuous readout enabled studies of detector electrical instabilities in- and off-beam at near breakdown voltages. Each technology has different advantages making it more suitable for various experimental conditions.

physics.ins-det

The $v^{1/3}_{3}/v^{1/2}_{2}$ ratio in PbAu collisions at $\sqrt{s_{\mathrm{NN}}} = $ 17.3 GeV: a hint of a hydrodynamic behavior

The Fourier harmonics, $v_2$ and $v_3$ of negative pions are measured at center-of-mass energy per nucleon pair of $\sqrt{s_{\mathrm{NN}}}$= 17.3 GeV around midrapidity by the CERES/NA45 experiment at the CERN SPS in 0--30\% central PbAu collisions with a mean centrality of 5.5\%. The analysis is performed in two centrality bins as a function of the transverse momentum $\mathrm{p_{\mathrm{T}}}$ from 0.05 GeV/$c$ to more than 2 GeV/$c$. This is the first measurement of the $v^{1/3}_{3}/v^{1/2}_{2}$ ratio as a function of transverse momentum at SPS energies, that reveals, independently of the hydrodynamic models, hydrodynamic behavior of the formed system. For $\mathrm{p_{\mathrm{T}}}$ above 0.5 GeV/$c$, the ratio is nearly flat in accordance with the hydrodynamic prediction and as previously observed by the ATLAS and ALICE experiments at the much higher LHC energies. The results are also compared with the SMASH-vHLLE hybrid model predictions, as well as with the SMASH model applied alone.

nucl-ex

The New Small Wheel electronics

The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the "small" Thin Gap Chambers, with a total of 2.45 Million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm$^{2}$ at the expected HL-LHC luminosity of $\mathcal{L}$=7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.

hep-ex

Letter of Intent: the NA60+ experiment

We propose a new fixed-target experiment for the study of electromagnetic and hard probes of the Quark-Gluon Plasma (QGP) in heavy-ion collisions at the CERN SPS. The experiment aims at performing measurements of the dimuon spectrum from threshold up to the charmonium region, and of hadronic decays of charm and strange hadrons. It is based on a muon spectrometer, which includes a toroidal magnet and six planes of tracking detectors, coupled to a vertex spectrometer, equipped with Si MAPS immersed in a dipole field. High luminosity is an essential requirement for the experiment, with the goal of taking data with 10$^6$ incident ions/s, at collision energies ranging from $\sqrt{s_{\rm NN}} = 6.3$ GeV ($E_{\rm lab}= 20$ A GeV) to top SPS energy ($\sqrt{s_{\rm NN}} = 17.3$ GeV, $E_{\rm lab}= 158$ A GeV). This document presents the physics motivation, the foreseen experimental set-up including integration and radioprotection studies, the current detector choices together with the status of the corresponding R&D, and the outcome of physics performance studies. A preliminary cost evaluation is also carried out.

nucl-ex

Elliptic flow of charged pions, protons and strange particles emitted in Pb+Au collisions at top SPS energy

Differential elliptic flow spectra v2(pT) of π-, K0short, p, Λhave been measured at \sqrt(s NN)= 17.3 GeV around midrapidity by the CERN-CERES/NA45 experiment in mid-central Pb+Au collisions (10% of σ(geo)). The pT range extends from about 0.1 GeV/c (0.55 GeV/c for Λ) to more than 2 GeV/c. Protons below 0.4 GeV/c are directly identified by dE/dx. At higher pT, proton elliptic flow v2(pT) is derived as a constituent, besides π+ and K+, of the elliptic flow of positive pion candidates. The retrieval requires additional inputs: (i) of the particle composition, and (ii) of v2(pT) of positive pions. For (i), particle ratios obtained by NA49 were adapted to CERES conditions; for (ii), the measured v2(pT) of negative pions is substituted, assuming π+ and π- elliptic flow magnitudes to be sufficiently close. The v2(pT) spectra are compared to ideal-hydrodynamics calculations. In synopsis of the series π- - K0short - p - Λ, flow magnitudes are seen to fall with decreasing pT progressively even below hydro calculations with early kinetic freeze-out (Tf= 160 MeV) leaving not much time for hadronic evolution. The proton v2(pT) data show a downward swing towards low pT with excursions into negative v2 values. The pion-flow isospin asymmetry observed recently by STAR at RHIC, invalidating in principle our working assumption, is found in its impact on proton flow bracketed from above by the direct proton flow data, and not to alter any of our conclusions. Results are discussed in perspective of recent viscous dynamics studies which focus on late hadronic stages.

nucl-ex

Design, Construction, Operation and Performance of a Hadron Blind Detector for the PHENIX Experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF4. It has a 50 cm long radiator directly coupled in a window- less configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

physics.ins-det

Azimuthal dependence of pion source radii in Pb+Au collisions at 158 A GeV

We present results of a two-pion correlation analysis performed with the Au+Pb collision data collected by the upgraded CERES experiment in the fall of 2000. The analysis was done in bins of the reaction centrality and the pion azimuthal emission angle with respect to the reaction plane. The pion source, deduced from the data, is slightly elongated in the direction perpendicular to the reaction plane, similarly as was observed at the AGS and at RHIC.

nucl-ex

A Hadron Blind Detector for the PHENIX Experiment

A novel Hadron Blind Detector (HBD) has been developed for an upgrade of the PHENIX experiment at RHIC. The HBD will allow a precise measurement of electron-positron pairs from the decay of the light vector mesons and the low-mass pair continuum in heavy-ion collisions. The detector consists of a 50 cm long radiator filled with pure CF4 and directly coupled in a windowless configuration to a triple Gas Electron Multiplier (GEM) detector with a CsI photocathode evaporated on the top face of the first GEM foil.

nucl-ex

e+e--pair production in Pb-Au collisions at 158 GeV per nucleon

We present the combined results on electron-pair production in 158 GeV/n {Pb-Au} ($\sqrt{s}$= 17.2 GeV) collisions taken at the CERN SPS in 1995 and 1996, and give a detailed account of the data analysis. The enhancement over the reference of neutral meson decays amounts to a factor of 2.31$\pm0.19 (stat.)\pm0.55 (syst.)\pm0.69 (decays)$ for semi-central collisions (28% $σ/σ_{geo}$) when yields are integrated over $m>$ 200 MeV/$c^2$ in invariant mass. The measured yield, its stronger-than-linear scaling with $N_{ch}$, and the dominance of low pair $p_t$ strongly suggest an interpretation as {\it thermal radiation} from pion annihilation in the hadronic fireball. The shape of the excess centring at $m\approx$ 500 MeV/$c^2$, however, cannot be described without strong medium modifications of the $ρ$ meson. The results are put into perspective by comparison to predictions from Brown-Rho scaling governed by chiral symmetry restoration, and from the spectral-function many-body treatment in which the approach to the phase boundary is less explicit.

nucl-ex

A Hadron Blind Detector for the PHENIX Experiment at RHIC

A Hadron Blind Detector (HBD) is being developed for the PHENIX experiment at RHIC. It consists of a Cherenkov radiator operated with pure CF4 directly coupled in a windowless configuration to a triple-GEM detector element with a CsI photocathode and pad readout. The HBD operates in the bandwidth 6-11.5 eV(110-200 nm). We studied the detector response to minimum ionizing particles and to electrons. We present measurements of the CsI quantum efficiency, which are in very good agreement with previously published results over the bandwidth 6-8.3 eV and extend them up to 10.3 eV. Discharge probability andaging studies of the GEMs and the CsI photocathode in pure CF4 are presented.

physics.ins-det

Development of a triple GEM UV-photon detector operated in pure CF4 for the PHENIX experiment

Results obtained with a triple GEM detector operated in pure CF4 with and without a reflective CsI photocathode are presented. The detector operates in a stable mode at gains up to 10^4. A deviation from exponential growth starts to develop when the total charge exceeds ~ 4 10^6 e leading to gain saturation when the total charge is ~ 2 10^7 e and making the structure relatively robust against discharges. No aging effects are observed in the GEM foils after a total accumulated charge of ~ 10 mC/cm^2 at the anode. The ion back-flow current to the reflective photocathode is comparable to the electron current to the anode. However, no significant degradation of the CsI photocathode is observed for a total ion back-flow charge of ~ 7 mC/cm^2.

physics.ins-det

Proposal for a Hadron Blind Detector for PHENIX

A Hadron Blind Detector (HBD) is proposed as upgrade of the PHENIX detector at RHIC, BNL. The HBD will allow the measurement of low-mass e+e- pairs from the decay of the light vector mesons rho, omega, phi and the low-mass continuum in Au-Au collisions at energies up to sqrt{s_{NN}}= 200 GeV. From MC simulations and general considerations, the HBD has to identify electrons with very high efficiency (> 90%), double hit recognition better than 90%, moderate pion rejection factor of ~200 and radiation budget of the order of 1% of a radiation length. The first choice under study is a windowless Cherenkov detector, operated with pure CF4, in a special proximity focus configuration with a CsI photocathode and a multistage GEM amplification element.

physics.ins-det