Searcharxiv⌕ Search

arXiv subjects

I. Rienäcker

Publications and source records attributed to I. Rienäcker.

15 recordsLinked to original sources

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~μ\mathrm{T} < B < 360~μ\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex↗

New high-sensitivity search for neutron to mirror-neutron oscillations at the PSI UCN source

In a search for potential signals of neutron (n) to mirror-neutron (n') oscillations, a collaboration centered at the Paul Scherrer Institute (PSI) investigated the remaining parameter space claimed by anomalies with a dedicated high-sensitivity apparatus. An elaborate magnetic-field-mapping analysis and Monte Carlo simulation of the cumulative n-n' oscillation probabilities along the neutron trajectories inside the storage vessel complemented the neutron data analysis. Magnetic fields were scanned in the range 5 microT < B < 109 microT. No evidence of anomalous neutron losses was found. Consequently, new limits for the n-n' oscillation time constant were set. The parameter space, previously claimed for potential signals, has been excluded to 99.98 %.

nucl-ex↗

Simulation and optimization of the Active Magnetic Shield of the n2EDM experiment

The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achieved through a combination of passive shielding, provided by a magnetically shielded room (MSR), and a surrounding active field compensation system by an Active Magnetic Shield (AMS). The AMS is a feedback-controlled system of eight coils spanned on an irregular grid, designed to provide magnetic stability to the enclosed volume by actively suppressing external magnetic disturbances. It can compensate static and variable magnetic fields up to $\pm 50$ $μ$T (homogeneous components) and $\pm 5$ $μ$T/m (first-order gradients), suppressing them to a few $μ$T in the sub-Hertz frequency range. We present a full finite element simulation of magnetic fields generated by the AMS in the presence of the MSR. This simulation is of sufficient accuracy to approach our measurements. We demonstrate how the simulation can be used with an example, obtaining an optimal number and placement of feedback sensors using genetic algorithms.

physics.ins-det↗

Ultracold neutron energy spectrum and storage properties from magnetically induced spin depolarization

We present a novel method for extracting the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements using the n2EDM apparatus. This method is also sensitive to the storage properties of the materials used to trap ultracold neutrons, specifically, whether collisions are specular or diffuse. We highlight the sensitivity of this new technique by comparing the two different storage chambers of the n2EDM experiment. We validate the extraction by comparing to an independent measurement for how this energy spectrum is polarized through a magnetic-filter, and finally, we calculate the neutron center-of-mass offset, an important systematic effect for measurements of the neutron electric dipole moment.

hep-ex↗

Temperature dependent ultracold neutron transmission in D$_2$ gas $-$ a test of the Young-Koppel model

The Young-Koppel model (YK) describes comprehensively the interaction of slow neutrons with diatomic gases such as H$_2$ and D$_2$. This paper reports on the first experimental results of ultracold neutron (UCN) scattering over a wide temperature range vindicating the YK model for gaseous D$_2$ and showing an important difference in the temperature dependence to a low-energy low-temperature approximation (LETA). LETA is confirmed, however, to be valid for monoatomic gases such as Ne. Calculated cross sections for other noble gases were also confirmed for ultracold neutrons. Finally, the total cross section of UCNs in H$_2$ gas was measured and analyzed applying the Young-Koppel model, however, in a more limited temperature range, confirming the theoretical prediction.

nucl-ex↗

Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.

physics.ins-det↗

A large 'Active Magnetic Shield' for a high-precision experiment

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

physics.ins-det↗

Time-of-flight spectroscopy of ultracold neutrons at the PSI UCN source

The ultracold neutron (UCN) source at the Paul Scherrer Institute (PSI) provides high intensities of storable neutrons for fundamental physics experiments. The neutron velocity spectrum parallel to the beamline axis was determined by time-of-flight spectroscopy using a neutron chopper. In particular, the temporal evolution of the spectrum during neutron production and UCN storage in the source storage volume was investigated and compared to Monte Carlo simulation results. A softening of the measured spectrum from a mean velocity of 7.7(1) m s$^{-1}$ to 5.1(1) m s$^{-1}$ occurred within the first 30 s after the proton beam pulse had impinged on the spallation target. A spectral hardening was observed over longer time scales of one measurement day, consistent with the effect of surface degradation of the solid deuterium moderator.

physics.ins-det↗

Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI

We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polarized ultracold neutrons stored in vacuum. The dominant systematic uncertainty resulting from magnetic-field gradients was controlled to an unprecedented level of approximately 4 pT/cm using an array of optically-pumped cesium vapor magnetometers and magnetic-field maps independently recorded using a dedicated measurement device. No signature of a theoretically predicted new interaction was found, and we set a new limit on the product of the scalar and the pseudoscalar couplings $g_sg_pλ^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) in a range of $5\,μ\text{m} < λ< 25\,\text{mm}$ for the monopole-dipole interaction. This new result confirms and improves our previous limit by a factor of 2.7 and provides the current tightest limit obtained with free neutrons.

nucl-ex↗

Characterization of ultracold neutron production in thin solid deuterium films at the PSI Ultracold Neutron source

We determined the ultracold neutron (UCN) production rate by superthermal conversion in the solid deuterium (sD$_2$) moderator of the UCN source at the Paul Scherrer Institute (PSI). In particular, we considered low amounts of less than $20\,$mol of D$_2$, deposited on the cooled moderator vessel surfaces in thin films of a few mm thickness. We measured the isotopic ($ c_\text{HD} < 0.2 \, \% $) and isomeric ($ c_\text{para} \le 2.7 \, \% $) purity of the deuterium to conclude that absorption and up-scattering at $5\,$K have a negligible effect on the UCN yield from the thin films. We compared the calculated UCN yield based on the previously measured thermal neutron flux from the heavy water thermal moderator with measurements of the UCN count rates at the beamports. We confirmed our results and thus demonstrate an absolute characterization of the UCN production and transport in the source by simulations.

physics.ins-det↗

The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1m3 below 100pT, and a field below 600pT in the entire inner volume, up to 4\,cm to the walls. The quasi-static shielding factor at 0.01\,Hz measured with a sinusoidal 2muT peak-to-peak signal is about 100,000 in all three spatial directions and rises fast with frequency to reach 10^8 above 1Hz.

physics.ins-det↗

Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments

Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped $^{133}$Cs magnetometers and $^{199}$Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of $4\,\times\,10^{-28}\,e\cdot{\rm cm}$ in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.

nucl-ex↗

The design of the n2EDM experiment

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.

physics.ins-det↗

Data blinding for the nEDM experiment at PSI

Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment, as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a fake signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons of each measurement cycle. The flexible algorithm is applied twice to the data, to provide different data to various analysis teams. This gives us the option to sequentially apply various blinding offsets for separate analysis steps with independent teams. The subtle modification of the data allows us to modify the algorithm and to produce a re-blinded data set without revealing the blinding secret. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable efforts.

physics.data-an↗

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

hep-ex↗