SearcharxivSearch

arXiv subjects

I. Ruo-Berchera

Publications and source records attributed to I. Ruo-Berchera.

6 recordsLinked to original sources

Twin beam quantum-enhanced correlated interferometry for testing fundamental physics

Quantum metrology deals with improving the resolution of instruments that are otherwise limited by shot noise and it is therefore a promising avenue for enabling scientific breakthroughs. The advantage can be even more striking when quantum enhancement is combined with correlation techniques among several devices. Here, we present and realize a correlation interferometry scheme exploiting bipartite quantum correlated states injected in two independent interferometers. The scheme outperforms classical analogues in detecting a faint signal that may be correlated/uncorrelated between the two devices. We also compare its sensitivity with that obtained for a pair of two independent squeezed modes, each addressed to one interferometer, for detecting a correlated stochastic signal in the MHz frequency band. Being the simpler solution, it may eventually find application to fundamental physics tests, e.g., searching for the effects predicted by some Planck scale theories.

quant-ph

Feasibility study towards comparison of the g^(2)(0) measurement in the visible range

This work reports on the pilot study, performed by INRIM, NPL and PTB, on the measurement of the g^(2)(0) parameter in the visible spectral range of a test single-photon source based on a colour centre in diamond. The development of single-photon sources is of great interest to the metrology community as well as the burgeoning quantum technologies industry. Measurement of the g^(2)(0) parameter plays a vital role in characterising and understanding single-photon emission. This comparison has been conducted by each partner individually using its own equipment at INRIM laboratories, which were responsible for the operation of the source

quant-ph

Absolute calibration of a CCD camera with twin beams

We report on the absolute calibration of a CCD camera by exploiting quantum correlation. This novel method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model taking into account all the possible source of losses and noise that are not related to the quantum efficiency,accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterizaion of (scientific) CCDs used in mesoscopic light regime.

quant-ph

Tailoring PDC speckle structure

Speckle structure of parametric down conversion light has recently received a large attention due to relevance in view of applications to quantum imaging The possibility of tailoring the speckle size by acting on the pump properties is an interesting tool for the applications to quantum imaging and in particular to the detection of weak object under shot-noise limit. Here we present a systematic detailed experimental study of the speckle structure produced in type II PDC with particular attention to its variation with pump beam properties.

quant-ph

Systematic study of the PDC speckle structure for quantum imaging applications

Sub shot noise imaging of weak object by exploiting Parametric Down Converted light represents a very interesting technological development. A precise characterization of PDC speckle structure in dependence of pump beam parameters is a fundamental tool for this application. In this paper we present a first set of data addressed to this purpose.

quant-ph

Absolute calibration of Analog Detectors using Stimulated Parametric Down Conversion

Spontaneous parametric down conversion has been largely exploited as a tool for absolute calibration of photon counting detectors, photomultiplier tubes or avalanche photodiodes working in Geiger regime. In this work we investigate the extension of this technique from very low photon flux of photon counting regime to the absolute calibration of analog photodetectors at higher photon flux. Moving toward higher photon rate, i.e. at high gain regime, with the spontaneous parametric down conversion shows intrinsic limitations of the method, while the stimulated parametric down conversion process, where a seed beam properly injected into the crystal in order to increase the photon generation rate in the conjugate arm, allows us to work around this problem. A preliminary uncertainty budget is discussed.

quant-ph