SearcharxivSearch

arXiv subjects

I. Sarra

Publications and source records attributed to I. Sarra.

At least 19 recordsLinked to original sources

Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter

CRILIN is a high-granularity semi-homogeneous electromagnetic calorimeter based on longitudinally segmented PbF$_2$ crystal matrices read out by UV-extended silicon photomultipliers. The concept combines fast Cherenkov response, fine transverse granularity, longitudinal shower information, and radiation tolerance for future lepton-collider experiments. This paper reports the construction of a large-area prototype and its performance measured in beam tests at the CERN SPS. The detector comprises five $7\times7$ PbF$_2$ crystal matrices, has a depth of about $22X_0$, and is read out by four $3\times3~\mathrm{mm}^2$ SiPMs per crystal integrated in a single electronic channel. Electron data between 10 and 120~GeV and dedicated 150~GeV muon data were used to characterize the detector response. A time resolution below 50~ps is achieved for electron energies above 10~GeV, reaching values below 20~ps above 60~GeV. The energy resolution is described by a stochastic term of $(6.58\pm0.04)\%/\sqrt{E/\mathrm{GeV}}$ and a constant term of $(0.23\pm0.02)\%$, with an additional noise contribution fixed from pedestal data. The longitudinal segmentation enables event-by-event corrections based on the reconstructed shower development, resulting in a significant improvement of the energy resolution. A light yield of approximately 0.54~photoelectrons/MeV is measured consistently using both electron showers and minimum-ionizing particles. A Geant4-based simulation incorporating the relevant experimental effects reproduces the measured energy resolution. These results validate the CRILIN architecture as a compact, fast, and longitudinally segmented electromagnetic calorimeter for future collider experiments.

physics.ins-det

3D software compensation of hadronic showers in the CRILIN crystal calorimeter

Future electron-positron Higgs factories require excellent jet energy resolution to perform precision measurements of Higgs boson couplings to quarks and gluons. Although homogeneous crystal calorimeters provide remarkable electromagnetic energy resolution, their highly non-compensating response makes hadronic energy reconstruction particularly challenging. In this work, software compensation techniques are investigated for CRILIN, a longitudinally segmented Cherenkov crystal electromagnetic calorimeter based on PbF$_2$ crystals. Using Geant4 simulations of pion showers, it is shown that shower-shape observables are strongly correlated with the fraction of deposited energy reconstructed in a CRILIN module. Simple event-by-event corrections based on the shower transverse RMS and longitudinal center-of-gravity already yield a substantial improvement in hadronic energy reconstruction. A ParticleNet Graph Neural Network exploiting the full three-dimensional shower topology achieves significantly improved performance with respect to simple energy sum reconstruction. Under several different assumptions for the downstream hadronic calorimeter resolution, the GNN-based reconstruction significantly reduces the effective CRILIN contribution to the combined calorimetric resolution, therefore preserving an excellent combined ECAL+HCAL performance. The dependence of the result on the assumed HCAL resolution is also studied and found to be limited within the range considered. These results demonstrate that highly granular crystal calorimeters can recover a large fraction of the information lost because of their intrinsically non-compensating response through software-based compensation techniques, enabling excellent hadronic energy resolution in a combined ECAL+HCAL system and making such detectors promising candidates for future collider experiments.

hep-ex

Search for a new 17 MeV resonance via $e^+e^-$ annihilation with the PADME Experiment

The PADME Experiment at the Frascati DA$\Phi$NE LINAC has searched for a hypothetical particle with mass around 17 MeV, commonly referred to as the X17, using a positron beam incident on a fixed target. The beam energy was varied between 262 and 296 MeV, corresponding to center-of-mass energies $\sqrt{s}$ between 16.4 and 17.4 MeV. The X17 should be produced resonantly via $e^+e^-$ annihilation when $\sqrt{s}$ approaches its mass, inducing an excess of events with a two-body final state over the background expectation. The beam energy spacing was fixed to less than half the expected width of the resonance's line shape. Uncertainties below 1% per $\sqrt{s}$ point were achieved. A blind analysis has been performed. The data are consistent with the expected background in most of the explored energy range, and limits are set in previously unexplored regions of the available parameter space. The most significant deviation is found for $\sqrt{s} \approx 16.90$ MeV, corresponding to a global significance of approximately 2 standard deviations over the null hypothesis expectation.

hep-ex

The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs

The Crilin calorimeter is a semi-homogeneous calorimetric system based on Lead Fluoride (PbF$_2$) crystals with UV-extended Silicon Photomultipliers (SiPMs) proposed for the Muon Collider. This study investigates the radiation resistance of crystals and SiPMs, subjected to 10 kGy gamma irradiation, equivalent to a 10-year service life in the Muon Collider. Our findings indicate that while PbF$_2$ crystals exhibit a decrease in transmittance post-irradiation with partial recovery over time, the alternative PbWO$_4$-Ultra Fast (PWO-UF) demonstrates exceptional radiation hardness, maintaining stable transmittance. SiPMs showed an increase in dark current and breakdown voltage post-irradiation, with less degradation observed in the SiPM biased during the exposure to radiation compared to the unbiased component. These results underscore the viability of PbF$_2$ for radiation-tolerant calorimeters, though improvements in production homogeneity are needed. The superior performance of PWO-UF crystals suggests they are a promising alternative for high-radiation applications, but their higher cost must be carefully considered.

physics.ins-det

Development of nanocomposite scintillators for use in high-energy physics

Semiconductor nanocrystals (quantum dots) are light emitters with high quantum yield that are relatively easy to manufacture. There is therefore much interest in their possible application for the development of high-performance scintillators for use in high-energy physics. However, few previous studies have focused on the response of these materials to high-energy particles. To evaluate the potential for the use of nanocomposite scintillators in calorimetry, we are performing side-by-side tests of fine-sampling shashlyk calorimeter prototypes with both conventional and nanocomposite scintillators using electron and minimum-ionizing particle beams, allowing direct comparison of the performance obtained.

physics.ins-det

Characterization of the PADME positron beam for the X17 measurement

This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within $\sim$ 1-2 MeV$/c$, a relative beam energy spread below 0.25\%, and an absolute precision in the intensity of the beam at the level of 2\% percent.

hep-ex

Workshop on a future muon program at FNAL

The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.

hep-ex

Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation

Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small ($10\times10\times40$~mm$^3$) lead fluoride (PbF$_2$) and ultra-fast lead tungstate (PbWO$_4$, PWO) crystals with 120~GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout scheme. For a single crystal of PbF$_2$, corresponding to a single Crilin cell, a time resolution of better than 25~ps is obtained for $>$3 GeV of deposited energy. For a single cell of \pwo, a time resolution of better than 45~ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.

physics.ins-det

HIKE, High Intensity Kaon Experiments at the CERN SPS

A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the Standard Model. The experimental programme is based on a staged approach involving experiments with charged and neutral kaon beams, as well as operation in beam-dump mode. The various phases will rely on a common infrastructure and set of detectors.

hep-ex

Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector

The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.

hep-ex

An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

physics.ins-det

Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider

The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeters should be chosen to reduce the effect of the BIB, while keeping good physics performance. Several requirements can be inferred: i) high granularity to reduce the overlap of BIB particles in the same calorimeter cell; ii) excellent timing (of the order of 100 ps) to reduce the out-of-time component of the BIB; iii) longitudinal segmentation to distinguish the signal showers from the fake showers produced by the BIB; iv) good energy resolution (less than 10%/sqrt(E)) to obtain good physics performance, as has been already demonstrated for conceptual particle flow calorimeters. Our proposal consists of a semi-homogeneous electromagnetic calorimeter based on Lead Fluoride Crystals (PbF2) readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs): the Crilin calorimeter. In this paper, the performances of the Crilin calorimeter in the Muon Collider framework for hadron jets reconstruction have been analyzed. We report the single components characterizations together with the development of a small-scale prototype, consisting of 2 layers of 3x3 crystals each.

physics.ins-det

Simulated Detector Performance at the Muon Collider

In this paper we report on the current status of studies on the expected performance for a detector designed to operate in a muon collider environment. Beam-induced backgrounds (BIB) represent the main challenge in the design of the detector and the event reconstruction algorithms. The current detector design aims to show that satisfactory performance can be achieved, while further optimizations are expected to significantly improve the overall performance. We present the characterization of the expected beam-induced background, describe the detector design and software used for detailed event simulations taking into account BIB effects. The expected performance of charged-particle reconstruction, jets, electrons, photons and muons is discussed, including an initial study on heavy-flavor jet tagging. A simple method to measure the delivered luminosity is also described. Overall, the proposed design and reconstruction algorithms can successfully reconstruct the high transverse-momentum objects needed to carry out a broad physics program.

hep-ex

Commissioning of the PADME experiment with a positron beam

The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target. This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.

physics.ins-det

Radiation study of Lead Fluoride crystals

Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total fluence. Their loss in transmittance was evaluated at different steps of the photon and neutron irradiation campaign, resulting in a total of 30% loss above 350 nm. With crystals always kept in dark conditions, natural and thermal annealing, as well as optical bleaching with 400 nm light, were performed on the irradiated specimens, resulting in a partial recovery of their original optical characteristics.

physics.ins-det

The PADME beam line Monte Carlo simulation

The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) of the INFN Laboratory of Frascati is designed to search for invisible decays of dark sector particles produced in electron-positron annihilation events with a positron beam and a thin fixed target, by measuring the missing mass of single-photon final states. The presence of backgrounds originating from beam halo particles can significantly reduce the sensitivity of the experiment. To thoroughly understand the origin of the beam background contribution, a detailed Geant4-based Monte Carlo simulation has been developed, containing a full description of the detector together with the beam line and its optical elements. This simulation allows the full interactions of each particle to be described, both during beam line transport and during detection, a possibility which represents an innovative way to obtain reliable background predictions

hep-ex

Mu2e-II: Muon to electron conversion with PIP-II

An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for examining the process on additional target materials. Mu2e-II is a proposed upgrade to Mu2e, with at least an additional order of magnitude in sensitivity to the conversion rate over Mu2e. The approach and challenges for this proposal are summarized. Mu2e-II may be regarded as the next logical step in a continued high-intensity muon program at FNAL.

hep-ex

A New Charged Lepton Flavor Violation Program at Fermilab

The muon has played a central role in establishing the Standard Model of particle physics, and continues to provide valuable information about the nature of new physics. A new complex at Fermilab, the Advanced Muon Facility, would provide the world's most intense positive and negative muon beams by exploiting the full potential of PIP-II and the Booster upgrade. This facility would enable a broad muon physics program, including studies of charged lepton flavor violation, muonium-antimuonium transitions, a storage ring muon EDM experiment, and muon spin rotation experiments. This document describes a staged realization of this complex, together with a series of next-generation experiments to search for charged lepton flavor violation.

hep-ex