SearcharxivSearch

arXiv subjects

I. Savvidis

Publications and source records attributed to I. Savvidis.

At least 19 recordsLinked to original sources

Search for Light Dark Matter with NEWS-G at the Laboratoire Souterrain de Modane Using a Methane Target

The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to protons. New constraints are presented in the mass range $0.17$ to $1.2\,\mathrm{GeV/c^2}$, with a 90% confidence level cross-section upper limit of $30.9\,\mathrm{pb}$ for a mass of $0.76\,\mathrm{GeV/c^2}$.

hep-ex

The ionization yield in a methane-filled spherical proportional counter

Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this technology to search for low-mass dark matter, having previously performed searches with detectors at the Laboratoire Souterrain de Modane (LSM), including a recent campaign with a 135 cm diameter SPC filled with methane. While in situ calibrations of the detector response were carried out at the LSM, measurements of the mean ionization yield and fluctuations of methane gas in SPCs were performed using a 30 cm diameter detector. The results of multiple measurements taken at different operating voltages are presented. A UV laser system was used to measure the mean gas gain of the SPC, along with $\mathrm{^{37}Ar}$ and aluminum-fluorescence calibration sources. These measurements will inform the energy response model of future operating detectors.

physics.ins-det

Exploring light dark matter with the DarkSPHERE spherical proportional counter electroformed underground at the Boulby Underground Laboratory

We present the conceptual design and the physics potential of DarkSPHERE, a proposed 3 m in diameter spherical proportional counter electroformed underground at the Boulby Underground Laboratory. This effort builds on the R&D performed and experience acquired by the NEWS-G Collaboration. DarkSPHERE is primarily designed to search for nuclear recoils from light dark matter in the 0.05--10 GeV mass range. Electroforming the spherical shell and the implementation of a shield based on pure water ensures a background level below 0.01 dru. These, combined with the proposed helium-isobutane gas mixture, will provide sensitivity to the spin-independent nucleon cross-section of $2\times 10^{-41} (2\times 10^{-43})$ cm$^2$ for a dark matter mass of $0.1 (1)$ GeV. The use of a hydrogen-rich gas mixture with a natural abundance of $^{13}$C provides sensitivity to spin-dependent nucleon cross-sections more than two orders of magnitude below existing constraints for dark matter lighter than 1 GeV. The characteristics of the detector also make it suitable for searches of other dark matter signatures, including scattering of MeV-scale dark matter with electrons, and super-heavy dark matter with masses around the Planck scale that leave extended ionisation tracks in the detector.

hep-ex

R2D2 TPC: first Xenon results

Radial time projection chambers (TPC), already employed in the search for rare phenomena such as light Dark Matter candidate, could provide a new detection approach for the search of neutrinoless double beta decay ($β\beta0ν$). The assessment of the performances of such a detector for $β\beta0ν$ search is indeed the goal of the Rare Decays with Radial Detector (R2D2) R\&D. Promising results operating a spherical TPC with argon up to 1~bar have been published in 2021. Supplementary measurements were recently taken extending the gas pressure range up to 3~bar. In addition, a comparison between two detector geometries, namely spherical (SPC for spherical proportional counter) and cylindrical (CPC for cylindrical proportional counter), was performed. Using a relatively simple gas purification system the CPC detector was also operated with xenon at 1~bar: an energy resolution of 1.4\% full-width at half-maximum was achieved for drift distances up to 17~cm. Much lower resolution was observed with the SPC. These results are presented in this article.

physics.ins-det

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve $\mathrm{sub-GeV/c^{2}}$ Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionization with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

physics.ins-det

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^α~/~(β+ E_K^α)$ with $α=0.70\pm0.08$ and $β= 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$

physics.ins-det

Solar Kaluza-Klein axion search with NEWS-G

Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal from the background, by identifying the separation of the interaction point of the two photons. The NEWS-G collaboration uses large volume Spherical Proportional Counters, gas-filled metallic spheres with a spherical anode in their centre. After observation of a single axionlike event in a 42 day long run with the SEDINE detector, a $90\%$ C.L. upper limit of $g_{aγγ}<8.99\cdot10^{-13}\,GeV^{-1}$ is set on the axion-photon coupling for a KK axion density on Earth of $n_{a}=4.07\cdot10^{13}\,m^{-3}$ and two extra dimensions of size $R = 1\,eV^{-1}$.

hep-ex

Quenching factor measurements of neon nuclei in neon gas

The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.

physics.ins-det

Copper electroplating for background suppression in the NEWS-G experiment

New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.

physics.ins-det

A resistive ACHINOS multi-anode structure with DLC coating for spherical proportional counters

The spherical proportional counter is a gaseous detector used in a variety of applications, including direct dark matter and neutrino-less double beta decay searches. The ACHINOS multianode structure is a read-out technology that overcomes the limitations of single-anode read-out structures for large-size detectors and operation under high pressure. A resistive ACHINOS is presented, where the 3D printed central component is coated in a Diamond-Like Carbon (DLC) layer. The production and testing of the structure, in terms of stability and resolution, is described. Further applications in fundamental physics and industry are also discussed.

physics.ins-det

Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment

Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.

physics.ins-det

Improved Search for Solar Chameleons with a GridPix Detector at CAST

We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, $β_γ< 5.7\times10^{10}$ for $1<β_\mathrm{m}<10^6$ at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to $12.5\,\mathrm{T}$.

hep-ex

A sparkless resistive glass correction electrode for the spherical proportional counter

A new anode support structure for the spherical proportional counter is presented that incorporates a resistive correction electrode made of glass. This electrode improves the electric field homogeneity versus angle while suppressing the probability and intensity of sparks compared to non-resistive alternatives. The configuration of the correction electrode was optimised with simulations. Such support structures have been constructed and measurements have demonstrated homogeneous response of the detector and operational stability. A measurement of the resistivity of the glass used is also presented.

physics.ins-det

New CAST Limit on the Axion-Photon Interaction

During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a world leading limit of $g_{aγ} < 0.66 \times 10^{-10} {\rm GeV}^{-1}$ (95% C.L.) on the axion-photon coupling strength for $m_a \lesssim 0.02$ eV. Compared with the first vacuum phase (2003--2004), the sensitivity was vastly increased with low-background x-ray detectors and a new x-ray telescope. These innovations also serve as pathfinders for a possible next-generation axion helioscope.

hep-ex

Neutron spectroscopy with the Spherical Proportional Counter

A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of $N_{2}$ with $C_{2}H_{6}$ and pure $N_{2}$ are studied for thermal and fast neutron detection, providing a new way for the neutron spectroscopy. The neutrons are detected via the ${}^{14}N(n, p)C^{14}$ and ${}^{14}N(n, α)B^{11}$ reactions. Here we provide studies of the optimum gas mixture, the gas pressure and the most appropriate high voltage supply on the sensor of the detector in order to achieve the maximum amplification and better resolution. The detector is tested for thermal and fast neutrons detection with a ${}^{252}Cf$ and a ${}^{241}Am-{}^{9}Be$ neutron source. The atmospheric neutrons are successfully measured from thermal up to several MeV, well separated from the cosmic ray background. A comparison of the spherical proportional counter with the current available neutron counters is also given.

physics.ins-det

Low energy recoil detection with a spherical proportional counter

We present low energy recoil detection results in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An ${}^{241}Am-{}^{9}{Be}$ fast neutron source is used in order to obtain neutron-nucleus elastic scattering events inside the gaseous volume of the detector. The detector performance in the $keV$ energy region was resolved by observing the $5.9\ keV$ line of a ${}^{55}Fe$ X-ray source, with energy resolution of $9\%$ ($σ$). The toolkit GEANT4 was used to simulate the irradiation of the detector by an ${}^{241}Am-{}^{9}{Be}$ source, while SRIM was used to calculate the Ionization Quenching Factor (IQF). The GEANT4 simulated energy deposition spectrum in addition with the SRIM calculated quenching factor provide valuable insight to the experimental results. The performance of the SPC in low energy recoil detection makes the detector a good candidate for a wide range of applications, including Supernova or reactor neutrino detection and Dark Matter (WIMP) searches (via coherent elastic scattering).

physics.ins-det

First results from the NEWS-G direct dark matter search experiment at the LSM

New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the spin-independent WIMP-nucleon scattering cross-section in the sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times \mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5 $\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to be installed at SNOLAB by summer 2018.

astro-ph.IM

A multiball read-out for the spherical proportional counter

We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high pressure operations. We have developed a multi-ball read-out system which consists of several balls sitting at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.

physics.ins-det