SearcharxivSearch

arXiv subjects

I. Smiljanic

Publications and source records attributed to I. Smiljanic.

8 recordsLinked to original sources

MEASUREMENT OF THE HIGGS BRANCHING RATIO BR($H\rightarrowγγ$) AT 3 TeV CLIC

In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the measured BR($H\rightarrowγγ$), and consequently of the Higgs coupling $g_{Hγγ}$ from the predictions of the Standard Model, may indicate New Physics. The Higgs decay to two photons is thus an interesting probe of the Higgs sector. This study is performed using simulation of the detector for CLIC and by considering all relevant physics and beam-induced processes in a full reconstruction chain. It is shown that the product of the Higgs production cross-section in $W^+W^-$ fusion and BR($H\rightarrowγγ$) can be measured with a relative statistical uncertainty of 5.5\%, assuming the integrated luminosity of 5 ab$^{-1}$ and unpolarized beams.

physics.acc-ph

Probing the CP properties of the Higgs sector at ILC

The violation of CP symmetry is one of Sakharov's conditions for the matter-antimatter asymmetry of the Universe. Currently known sources of CP violation in the quark and neutrino sectors are insufficient to account for this. Is CP also violated in the Higgs sector? Could the SM-like Higgs boson be a mixture of even and odd CP states of an extended Higgs sector? With what precision could such effects be measured at future electron-positron colliders? These questions will be discussed in the light of the latest and ongoing studies at ILC.

hep-ph

Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up

A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.

physics.ins-det

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

physics.ins-det

ECFA Detector R&D Panel, Review Report

Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.

physics.ins-det

Precision luminosity measurement at ILC

In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective methods we introduce, leads to the systematic uncertainty from the beam-induced effects to be at a few permille level in the peak region above the 80% of the nominal centre-of-mass energies at ILC.

physics.acc-ph

Luminosity measurement at ILC

In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced to a permille independently of the precision with which the beam parameters are known. With the specific event selection, different from the isolation cuts based on topology of the signal used at LEP, combined with the corrective methods we introduce, the overall systematic uncertainty in the peak region above 80% of the nominal center-of-mass energy meets the physics requirements to be at the few permille level at all ILC energies.

physics.acc-ph

Luminosity Measurement at ILC

More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its integration in the forward region are presented. The impact of several effects contributing to the systematic uncertainty of luminosity measurement is given.

physics.ins-det