Design and Implementation of the Fast Data Processing System for the Baikal-GVD Neutrino Telescope

We present a fast data processing system for the Baikal-GVD neutrino telescope, designed for rapid identification of astrophysical neutrino events. Leveraging Baikal-GVD's modular cluster architecture, the system implements parallelized file processing where raw data files undergo concurrent analysis across dedicated virtual machines. The system implements two pipelines: a fast per-file processing and a fully fledged (per-run) processing, which integrates dynamic detector geometry determined from acoustic and inertial positioning systems and data quality monitoring with a latency of about 27 hr. The fast processing pipeline delivers a total latency of about 1.5-18 minutes from event detection to reconstructed data availability, depending on water luminescence levels. This enables fast follow-up observations of transient astrophysical sources, fulfilling Baikal-GVD's role in multi-messenger networks. The article also highlights key features of the data acquisition system, the integration of advanced synchronization systems and a robust infrastructure for data handling and storage, ensuring efficient and reliable operation of the Baikal-GVD telescope.

astro-ph.IM

Optimized scintillation strip design for the DANSS upgrade

DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile neutrino exclusion regions. Yet a moderate energy resolution of the detector prevents the further progress in the physics program. The main challenge of the planned upgrade is to achieve the energy resolution of 12% at 1 MeV. The new design of the main sensitive element - the plastic scintillation strip - is the most important step forward. The strip prototypes were manufactured and tested at the pion beam of the PNPI synchrocyclotron. More than twice higher light output together with fairly flat detector response uniformity, longitudinal timing information and other optimizations will surely help to reach the upgrade goal. The paper discusses the drawbacks of the current strip version, outlines the new features of the proposed upgrade, describes the beam test procedure and presents the test results reflecting the advantages of the new strip design in comparison with the currently used version.

physics.ins-det

Improved limits on $β^+$EC and ECEC processes in $^{74}$Se

New limits on $β^+$EC and ECEC processes in $^{74}$Se have been obtained using a 600 cm$^3$ HPGe detector and an external source consisting of 1600 g of a natural selenium powder. For different $β^+$EC and ECEC transitions (to the ground and excited states) obtained limits are on the level $\sim (0.2-4.8)\times10^{19}$ yr at 90\% C.L. In particular, for the potentially resonant transition into the 1204.2 keV excited state of $^{74}$Ge a lower half-life limit of $1.1\times10^{19}$ yr at 90\% C.L. has been obtained. Possibility to increase the sensitivity of such measurements is discussed.

nucl-ex

Data Quality Monitoring system in the Baikal-GVD experiment

The quality of the incoming experimental data has a significant importance for both analysis and running the experiment. The main point of the Baikal-GVD DQM system is to monitor the status of the detector and obtained data on the run-by-run based analysis. It should be fast enough to be able to provide analysis results to detector shifter and for participation in the global multi-messaging system.

astro-ph.IM

The optical noise monitoring systems of Lake Baikal environment for the Baikal-GVD telescope

We present data on the luminescence of the Baikal water medium collected with the Baikal-GVD neutrino telescope. This three-dimensional array of light sensors allows the observation of time and spatial variations of the ambient light field. We report on observation of an increase of luminescence activity in 2016 and 2018. On the contrary, we observed practically constant optical noise in 2017. An agreement has been found between two independent optical noise data sets. These are data collected with online monitoring system and the trigger system of the cluster.

astro-ph.HE

Neutrino Telescope in Lake Baikal: Present and Future

A significant progress in the construction and operation of the Baikal Gigaton Volume Detector in Lake Baikal, the largest and deepest freshwater lake in the world, is reported. The effective volume of the detector for neutrino initiated cascades of relativistic particles with energy above 100 TeV has been increased up to about 0.25 cubic kilometer. This unique scientific facility, the largest operating neutrino telescope in Northern Hemisphere, allows already to register two to three events per year from astrophysical neutrinos with energies exceeding 100 TeV. Preliminary results obtained with data recorded in 2016-2018 are announced. Multimessenger approach is used to relate finding of cosmic neutrinos with those of classical astronomers, with X-ray or gamma-ray observations and the gravitational wave events.

astro-ph.HE

Search for cascade events with Baikal-GVD

Baikal-GVD is a next generation, kilometer-scale neutrino telescope currently under construction in Lake Baikal. GVD is formed by multi-megaton sub-arrays (clusters) and is designed for the detection of astrophysical neutrino fluxes at energies from a few TeV up to 100 PeV. The design of the Baikal-GVD allows one to search for astrophysical neutrinos with flux values measured by IceCube already at early phases of the array construction. We present here preliminary results of the search for high-energy neutrinos via the cascade mode with the Baikal-GVD neutrino telescope.

astro-ph.HE

The Baikal-GVD neutrino telescope: First results of multi-messenger studies

Multi-messenger astronomy is a powerful tool to study the physical processes driving the non-thermal Universe. A combination of observations in cosmic rays, neutrinos, photons of all wavelengths and gravitational waves is expected. The alert system of the Baikal-GVD detector under construction will allow for a fast, on-line reconstruction of neutrino events recorded by the Baikal-GVD telescope and - if predefined conditions are satisfied - for the formation of an alert message to other communities. The preliminary results of searches for high-energy neutrinos in coincidence with GW170817/GRB170817A using the cascade mode of neutrino detection are discussed. Two Baikal-GVD clusters were operating during 2017. The zenith angle of NGC 4993 at the detection time of the GW170817 was 93.3 degrees. No events spatially coincident with GRB170817A were found. Given the non-detection of neutrino events associated with GW170817, upper limits on the neutrino fluence were established.

astro-ph.HE

The Baikal-GVD detector calibration

In April 2019, the Baikal-GVD collaboration finished the installation of the fourth and fifth clusters of the neutrino telescope Baikal-GVD. Momentarily, 1440 Optical Modules (OM) are installed in the largest and deepest freshwater lake in the world, Lake Baikal, instrumenting 0.25 cubic km of sensitive volume. The Baikal-GVD is thus the largest neutrino telescope on the Northern Hemisphere. The first phase of the detector construction is going to be finished in 2021 with 9 clusters, 2592 OMs in total, however the already installed clusters are stand-alone units which are independently operational and taking data from their commissioning. Huge number of channels as well as strict requirements for the precision of the time and charge calibration (ns, p.e.) make calibration procedures vital and very complex tasks. The inter cluster time calibration is performed with numerous calibration systems. The charge calibration is carried out with a Single Photo-Electron peak. The various data acquired during the last three years in regular and special calibration runs validate successful performance of the calibration systems and of the developed calibration techniques. The precision of the charge calibration has been improved and the time dependence of the obtained calibration parameters have been cross-checked. The multiple calibration sources verified a 1.5 - 2.0 ns precision of the in-situ time calibrations. The time walk effect has been studied in detail with in situ specialized calibration runs.

astro-ph.IM

A positioning system for Baikal-GVD

A cubic kilometer scale neutrino telescope Baikal-GVD is currently under construction in Lake Baikal. Baikal-GVD is designed to detect Cerenkov radiation from products of astrophysical neutrino interactions with Baikal water by a lattice of photodetectors submerged between the depths of 1275 and 730 m. The detector components are mounted on flexible strings and can drift from their initial positions upwards to tens of meters. This introduces positioning uncertainty which translates into a timing error for Cerenkov signal registration. A spatial positioning system has been developed to resolve this issue. In this contribution, we present the status of this system, results of acoustic measurements and an estimate of positioning error for an individual component.

astro-ph.IM

The inter-cluster time synchronization systems within the Baikal-GVD detector

Currently in Lake Baikal, a new generation neutrino telescope is being deployed: the deep underwater Cherenkov detector of a cubic-kilometer scale Baikal-GVD. Completion of the first stage of the telescope construction is planned for 2021 with the implementation of 9 clusters. Each cluster is a completely independent unit in all the aspects: triggering, calibration, data transfer, etc. A high-energy particle might leave its trace in more than a single cluster. To be able to merge events caused by such a particle in more clusters, the appropriate inter-cluster time synchronization is vital.

physics.ins-det

Properties of GaAs:Cr-based Timepix detectors

It is the hybrid pixel detector technology which brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon as the most widespread detector material is marginally sensitive to photons with energy more than 30 keV. That's why the high-Z alternatives to silicon such as gallium arsenide and cadmium telluride are increasingly attracting attention of the community for the development of X-ray imaging systems in recent years. We present in this work the results of our investigations of the Timepix detectors bump-bonded with sensors made of gallium arsenide compensated by chromium (GaAs:Cr). The properties which are mostly important from the practical point of view: IV characteristics, charge transport characteristics, operational stability, homogeneity, temperature dependence as well as energy and spatial resolution are considered. Applicability of these detectors for spectroscopic X-ray imaging is discussed.

physics.ins-det

Final Results of the PICASSO Dark Matter Search Experiment

The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to allow fiducialization and removal of higher activity regions within the detectors. No signal consistent with dark matter was observed. We set limits for spin-dependent interactions on protons of $σ_p^{SD}$~=~1.32~$\times$~10$^{-2}$~pb (90\%~C.L.) at a WIMP mass of 20 GeV/c$^{2}$. In the spin-independent sector we exclude cross sections larger than $σ_p^{SI}$~=~4.86~$\times$~10$^{-5 }$~pb~(90\% C.L.) in the region around 7 GeV/c$^{2}$. The pioneering efforts of the PICASSO experiment have paved the way forward for a next generation detector incorporating much of this technology and experience into larger mass bubble chambers.

hep-ex

The COBRA demonstrator at the LNGS underground laboratory

The COBRA demonstrator, a prototype for a large-scale experiment searching for neutrinoless double beta-decay, was built at the underground laboratory Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It consists of an array of 64 monolithic, calorimetric CdZnTe semiconductor detectors with a coplanar-grid design and a total mass of 380g. It is used to investigate the experimental challenges faced when operating CdZnTe detectors in low-background mode, to identify potential background sources and to show the long-term stability of the detectors. The first data-taking period started in 2011 with a subset of the detectors, while the demonstrator was completed in November 2013. To date, more than 250kg d of data have been collected. This paper describes technical details of the experimental setup and the hardware components.

physics.ins-det

Reference material for natural radionuclides in glass designed for underground experiments

A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participating laboratories, however, the number of data and precision was too low to carry out a certification process. The reference material may be used for quality management of analytical laboratories engaged in the high-sensitive analysis of radionuclides in the construction materials of detectors placed in ultra low background underground laboratories.

physics.ins-det

Constraints on Low-Mass WIMP Interactions on 19F from PICASSO

Recent results from the PICASSO dark matter search experiment at SNOLAB are reported. These results were obtained using a subset of 10 detectors with a total target mass of 0.72 kg of 19F and an exposure of 114 kgd. The low backgrounds in PICASSO allow recoil energy thresholds as low as 1.7 keV to be obtained which results in an increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below 10 GeV/c^2. No dark matter signal was found. Best exclusion limits in the spin dependent sector were obtained for WIMP masses of 20 GeV/c^2 with a cross section on protons of sigma_p^SD = 0.032 pb (90% C.L.). In the spin independent sector close to the low mass region of 7 GeV/c2 favoured by CoGeNT and DAMA/LIBRA, cross sections larger than sigma_p^SI = 1.41x10^-4 pb (90% C.L.) are excluded.

hep-ex

New Insights into Particle Detection with Superheated Liquids

We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy thresholds for $α$-emitters are compared with test beam measurements using mono-energetic neutrons, as well as with theoretical predictions. Finally a model is presented which describes how the observed intensities of particle induced acoustic signals can be related to the dynamics of bubble growth in superheated liquids. An improved understanding of the bubble dynamics is an important first step in obtaining better discrimination between particle types interacting in detectors of this kind.

physics.ins-det

Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.

nucl-ex