SearcharxivSearch

arXiv subjects

I. Tikhomirov

Publications and source records attributed to I. Tikhomirov.

5 recordsLinked to original sources

Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.

physics.ins-det

A scintillator based muon and KLong detector for the Belle II experiment

A new muon and K_Long detector based on scintillators will be used for the endcap and inner barrel regions in the Belle II experiment, currently under construction. The increased luminosity of the e+e- SuperKEKB collider entails challenging detector requirements. We demonstrate that relatively inexpensive polystyrene scintillator stips with wave length shifting fibers ensure a sufficient light yield at the Silcon PhotoMultiplier (SiPM) photodetector, are robust and provide improved physics performance for the Belle II experiment compared to its predecessor, Belle.

physics.ins-det

DANSSino: a pilot version of the DANSS neutrino detector

DANSSino is a reduced pilot version of a solid-state detector of reactor antineutrinos (to be created within the DANSS project and installed under the industrial 3 GW(th) reactor of the Kalinin Nuclear Power Plant -- KNPP). Numerous tests performed at a distance of 11 m from the reactor core demonstrate operability of the chosen design and reveal the main sources of the background. In spite of its small size (20x20x100 ccm), the pilot detector turned out to be quite sensitive to reactor antineutrinos, detecting about 70 IBD events per day with the signal-to-background ratio about unity.

physics.ins-det

First study of η_c, η(1760) and X(1835) production via η'π^+π^- final states in two-photon collisions

The invariant mass spectrum of the η' π^+ π^- final state produced in two-photon collisions is obtained using a 673 fb^{-1} data sample collected in the vicinity of the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a clear signal of the η_c and measure its mass and width to be M(η_c)=(2982.7 +- 1.8(stat) +- 2.2(syst) +- 0.3(model)) MeV/c^2 and Γ(η_c) = (37.8^{+5.8}_{-5.3}(stat) +- 2.8(syst) +- 1.4(model)) MeV/c^2. The third error is an uncertainty due to possible interference between the η_c and a non-resonant component. We also report the first evidence for η(1760) decay to η' π^+ π^-; we find two solutions for its parameters, depending on the inclusion or not of the X(1835), whose existence is of marginal significance in our data. From a fit to the mass spectrum using coherent X(1835) and η(1760) resonant amplitudes, we set a 90% confidence level upper limit on the product Γ_{γγ} \BR (η' π^+ π^-) for the X(1835).

hep-ex

Study of Scintillator Strip with Wavelength Shifting Fiber and Silicon Photomultiplier

The performance of the $200\times2.5\times1$ cm$^3$ plastic scintillator strip with wavelength shifting fiber read-out by two novel photodetectors called Silicon PhotoMultipliers (SiPMs) is discussed. The advantages of SiPM relative to the traditional multichannel photomultiplier are shown. Light yield and light attenuation measurements are presented. This technique can be used in muon or calorimeter systems.

physics.ins-det