SearcharxivSearch

arXiv subjects

I. Vai

Publications and source records attributed to I. Vai.

16 recordsLinked to original sources

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $\sigma = 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $\sigma \approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10M{\Omega} resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200k{\Omega}) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det

A Muon Collider Facility for Physics Discovery

Muon colliders provide a unique route to deliver high energy collisions that enable discovery searches and precision measurements to extend our understanding of the fundamental laws of physics. The muon collider design aims to deliver physics reach at the highest energies with costs, power consumption and on a time scale that may prove favorable relative to other proposed facilities. In this context, a new international collaboration has formed to further extend the design concepts and performance studies of such a machine. This effort is focused on delivering the elements of a $\sim$10 TeV center of mass (CM) energy design to explore the physics energy frontier. The path to such a machine may pass through lower energy options. Currently a 3 TeV CM stage is considered. Other energy stages could also be explored, e.g. an s-channel Higgs Factory operating at 125 GeV CM. We describe the status of the R&D and design effort towards such a machine and lay out a plan to bring these concepts to maturity as a tool for the high energy physics community.

physics.acc-ph

MPGDs for tracking and Muon detection at future high energy physics colliders

In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high background environments are required in order to accomplish the physics program. MPGDs offer a diversity of technologies that allow them to meet the required performance challenges at future facilities thanks to the specific advantages that each technology provides. MPGDs allow stable operation, with environmentally friendly gas mixtures, at very high background particle flux with high detection efficiency and excellent spatial resolution. These features make MPGD one of the primary choices as precise muon tracking and trigger system in general-purpose detectors at future HEP colliders. In addition, the low material budget and the flexibility of the base material make MPGDs suitable for the development of very light, full cylindrical fine tracking inner trackers at lepton colliders. On-going R&Ds aim at pushing the detector performance at the limits of each technology. We are working in continuing to consolidate the construction and stable operation of large-size detectors, able to cope with large particle fluxes. In this white paper, we describe some of the most prominent MPGD technologies, their performance measurements, the challenges faced in the most recent applications, and the areas of improvement towards efficient tracking and Muon detection at future high energy physics colliders.

physics.ins-det

High rate, fast timing Glass RPC for the high η CMS muon detectors

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high $η$ muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.

physics.ins-det

R&D towards the CMS RPC Phase-2 upgrade

The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.

physics.ins-det

Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.

physics.ins-det

Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope

We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam line to examine the rate capabilities of the prototype RPCs. In contrast to the case of the four-gap RPCs, we found the relatively high threshold was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-η endcap RPCs planned for future phase-II LHC runs.

physics.ins-det