SearcharxivSearch

arXiv subjects

I. Zoi

Publications and source records attributed to I. Zoi.

5 recordsLinked to original sources

First evaluation of the tracking performance of the ARCADIA Fully Depleted MAPS with 120 GeV proton beam

This work presents test beam characterization of the ARCADIA Main Demonstrator 3, a 200 $\mu$m thick Fully Depleted MAPS developed using a custom LFoundry 110 nm CIS process on a high-resistivity substrate. Measurements using a 120 GeV proton beam demonstrate a detection efficiency exceeding 99% and a spatial resolution down to 3.8 $\mu$m. The study evaluates cluster size, spatial resolution, and efficiency as a function of the threshold, front-end currents, and backside bias voltage.

physics.ins-det

Impact of front-end parameters of the ARCADIA MD3 on charged particle detection

The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 $\mu$m active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.

physics.ins-det

Pixel response characterization of the ARCADIA Fully Depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a $^{55}$Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

physics.ins-det

Position reconstruction for segmented detectors

The topic of the paper is the position reconstruction from signals of segmented detectors. With the help of a simple simulation, it is shown that the position reconstruction using the centre-of-gravity method is strongly biased, if the width of the charge (or e.g. light) distribution at the electrodes (or photo detectors) is less than the read-out pitch. A method is proposed which removes this bias for events with signals in two or more read-out channels and thereby improves the position resolution. The method also provides an estimate of the position-response function for every event. Examples are given for which its width as a function of the reconstructed position varies by as much as an order of magnitude. A fast Monte Carlo program is described which simulates the signals from a silicon pixel detector traversed by charged particles under different angles, and the results obtained with the proposed reconstruction method and with the centre-of-gravity method are compared. The simulation includes the local energy-loss fluctuations, the position-dependent electric field, the diffusion of the charge carriers, the electronics noise and charge thresholds for clustering. A comparison to test-beam-data is used to validate the simulation.

physics.ins-det

Position resolution with 25 um pitch pixel sensors before and after irradiation

Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. Additionally, fluences up to 2.3 10^16 cm^-2 1 MeV neutron equivalent at 3.0 cm distance from the beam are expected for an integrated luminosity of 3000 fb^-1. In the last decades, the pixel pitch has constantly been reduced to cope with the experiment's needs of achieving higher position resolution and maintaining low pixel occupancy per channel. The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. This paper describes position resolution measurements on planar prototype sensors with 100x25 um^2 pixels for the CMS Phase-2 Upgrade. It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip, and the bias voltage. A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to F_eq = 3.6 10^15 cm-2. The measurements were performed with a 5 GeV electron beam. A spatial resolution of 3.2 +\- 0.1 um is found for non-irradiated sensors, at the optimal angle for charge sharing. The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2.

physics.ins-det