SearcharxivSearch

arXiv subjects

Iain Martin

Publications and source records attributed to Iain Martin.

4 recordsLinked to original sources

Use of Bayesian Inference to Diagnose Issues in Experimental Measurements of Mechanical Disk Resonators

Gravitational wave detectors, such as LIGO, are predominantly limited by coating Brownian thermal noise (CTN), arising from mechanical losses in the Bragg mirror coatings used on test-mass optics. Accurately characterizing and minimizing these losses is crucial for enhancing detector sensitivity. This paper introduces a general mathematical and statistical framework leveraging Bayesian inference to precisely analyse mechanical ring-down measurements of disk resonators, a standard method for quantifying mechanical loss in coating materials. Our approach presents a refined model that fully captures the non-linear behaviour of beam spot motion on split photodiode sensors, significantly improving upon traditional simplified exponential-decay methods. We achieve superior estimation accuracy for decay constants ($\tau_1$ and $\tau_2$), especially for measurements exhibiting larger oscillation amplitudes. Specifically, we observe improvements in estimation accuracy by up to 25$\%$ over traditional methods, with strong Bayesian evidence favouring our framework. Our simulations and experimental validations reveal that previously discarded measurements due to fitting inaccuracies can now be reliably analysed, maximizing the use of available data. This enhanced analytical capability not only provides more precise mechanical loss estimations but also offers deeper insights into systematic issues affecting disk resonator measurements, paving the way toward improved coating materials and ultimately, more sensitive gravitational wave detectors.

physics.ins-det

A Cryogenic Silicon Interferometer for Gravitational-wave Detection

The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.

astro-ph.IM

Mirror thermal noise in laser interferometer gravitational wave detectors operating at room and cryogenic temperature

Mirror thermal noise is and will remain one of the main limitations to the sensitivity of gravitational wave detectors based on laser interferometers. We report about projected mirror thermal noise due to losses in the mirror coatings and substrates. The evaluation includes all kind of thermal noises presently known. Several of the envisaged substrate and coating materials are considered. The results for mirrors operated at room temperature and at cryogenic temperature are reported.

gr-qc

On the mechanical quality factors of cryogenic test masses from fused silica and crystalline quartz

Current interferometric gravitational wave detectors (IGWDs) are operated at room temperature with test masses made from fused silica. Fused silica shows very low absorption at the laser wavelength of 1064 nm. It is also well suited to realize low thermal noise floors in the detector signal band since it offers low mechanical loss, i. e. high quality factors (Q factors) at room temperature. However, for a further reduction of thermal noise, cooling the test masses to cryogenic temperatures may prove an interesting technique. Here we compare the results of Q factor measurements at cryogenic temperatures of acoustic eigenmodes of test masses from fused silica and its crystalline counterpart. Our results show that the mechanical loss of fused silica increases with lower temperature and reaches a maximum at 30 K for frequencies of slightly above 10 kHz. The losses of crystalline quartz generally show lower values and even fall below the room temperature values of fused silica below 10 K. Our results show that in comparison to fused silica, crystalline quartz has a considerably narrower and lower dissipation peak on cooling and thus has more promise as a test mass material for IGDWs operated at cryogenic temperatures. The origin of the different Q factor versus temperature behavior of the two materials is discussed.

gr-qc