Searcharxiv⌕ Search

arXiv subjects

Ida Häggström

Publications and source records attributed to Ida Häggström.

13 recordsLinked to original sources

What Matters is the Prompt: Prompt Sensitivity and Prompt Generation in Foundation Models for Lung Nodule Segmentation

Lung nodule segmentation in computed tomography is essential for extracting clinically relevant information for lung cancer assessment and treatment planning. Foundation models have shown notable segmentation capabilities, but state-of-the-art approaches often depend on input prompts, such as points or boxes, making their performance sensitive to prompt quality and placement. Understanding the limitations and constraints of prompt-based foundation models is therefore essential for designing reliable medical image segmentation solutions. In this work, we investigate how prompt quality affects foundation models performance for lung nodule segmentation. We further propose a synthetic prompt-generation model to test if the dependence on manually provided prompts can be mitigated by generating synthetic prompts that can also improve segmentation performance. Perturbation experiments show that bounding box prompts generally outperform point prompts, while latest specialized medical imaging models achieve better performance than general purpose ones. The proposed approach obtains a Dice coefficient of 0.85, suggesting that synthetic prompt generation as a promising strategy for lung nodule segmentation with foundation models.

eess.IV↗

CT-CLIP Representations for Multimodal Lung Cancer Survival Prediction

Accurate prognosis prediction is important for treatment planning in lung cancer, but deep learning-driven survival modelling is often limited by the scarcity of curated imaging cohorts with reliable outcome data. This study evaluates whether representations from a domain-specific foundation model can be used for multimodal survival prediction in data-constrained clinical settings. We assess the foundation model CT-CLIP as a feature extractor for pretreatment computed tomography images and clinical variables from 242 diagnosed lung cancer patients. The evaluation includes adaptation strategies based on frozen encoders, full fine-tuning, and low-rank adaptation, together with modality ablations and comparisons with clinical and multimodal baselines. The results show that a frozen CT-CLIP model combined with a trainable lightweight survival head outperforms the clinical baseline and achieves comparable or improved performance relative to other multimodal approaches, and separates patients into clinically meaningful high- and low-risk groups.

cs.CV↗

CEVAR: Centerline Embedding Extraction for Endovascular Aneurysm Repair

Long-term mortality rates after endovascular aneurysm repair (EVAR) remain elevated due to post-EVAR rupture caused by loss of seal in stent graft sealing zones. Structured CT review using centerline measurements improves detection, but current workflows require manual centerline editing and expert operators. We propose a transformer framework for automated, protocol-driven sealing zone assessment that combines 3D centerline tracking with embedding-based geometric prediction. Two state-of-the-art image-to-graph models are evaluated for aorto-iliac centerline extraction from follow-up CT and for measurement of stent position, vessel diameters, and seal lengths according to EVAR4C protocol. Across the full test set and a challenging no-contrast subset, the proposed fully automatic method outperforms the commercial semi-automatic workflow.

cs.CV↗

Medical Image Understanding Improves Survival Prediction via Visual Instruction Tuning

Accurate prognostication and risk estimation are essential for guiding clinical decision-making and optimizing patient management. While radiologist-assessed features from CT scans provide valuable indicators of disease severity and outcomes, interpreting such images requires expert knowledge, and translating rich visual information into textual summaries inevitably leads to information loss. In this work, we propose a vision-language framework for 3D CT image understanding that leverages large-scale open-sourced CT images paired with radiology reports through visual instruction tuning. This pre-training enables the model to learn clinically meaningful visual-textual representations, which can then be adapted to downstream survival prediction tasks. By incorporating a survival prediction head on top of the pre-trained model, our approach improves survival prediction from CT images and clinical data while generating clinically meaningful language responses to predefined questions. Experimental results demonstrate that our method outperforms baseline methods in survival prediction, particularly, when clinical data alone is less predictive. The code will be released upon acceptance.

cs.CV↗

Exemplar Diffusion: Improving Medical Object Detection with Opportunistic Labels

We present a framework to take advantage of existing labels at inference, called \textit{exemplars}, in order to improve the performance of object detection in medical images. The method, \textit{exemplar diffusion}, leverages existing diffusion methods for object detection to enable a training-free approach to adding information of known bounding boxes at test time. We demonstrate that for medical image datasets with clear spatial structure, the method yields an across-the-board increase in average precision and recall, and a robustness to exemplar quality, enabling non-expert annotation. Moreover, we demonstrate how our method may also be used to quantify predictive uncertainty in diffusion detection methods. Source code and data splits openly available online: https://github.com/waahlstrand/ExemplarDiffusion

cs.CV↗

Impact of deep learning model uncertainty on manual corrections to auto-segmentation in prostate cancer radiotherapy

Background: Deep learning (DL)-based organ segmentation is increasingly used in radiotherapy, yet voxel-wise DL uncertainty maps are rarely presented to clinicians. Purpose: This study assessed how DL-generated uncertainty maps impact radiation oncologists during manual correction of prostate radiotherapy DL segmentations. Methods: Two nnUNet models were trained by 10-fold cross-validation on 434 MRI-only prostate cancer cases to segment the prostate and rectum. Each model was evaluated on 35 independent cases. Voxel-wise uncertainty was calculated using the SoftMax standard deviation (n=10) and visualized as a color-coded map. Four oncologists performed segmentation in two steps: Step 1: Rated segmentation quality and confidence using Likert scales and edited DL segmentations without uncertainty maps. Step 2 ($\geq 4$ weeks later): Repeated step 1, but with uncertainty maps available. Segmentation time was recorded for both steps, and oncologists provided qualitative free-text feedback. Histogram analysis compared voxel edits across uncertainty levels. Results: DL segmentations showed high agreement with oncologist edits. Quality ratings varied: rectum segmentation ratings slightly decreased overall in step 2, while prostate ratings differed among oncologists. Confidence ratings also varied. Three oncologists reduced segmentation time with uncertainty maps, saving 1-2 minutes per case. Histogram analysis showed 50% fewer edits for step 2 in low-uncertainty areas. Conclusions: Presenting DL segmentation uncertainty information to radiation oncologists influences their decision-making, quality perception, and confidence in the DL segmentations. Low-uncertainty regions were edited less frequently, indicating increased trust in DL predictions. Uncertainty maps improve efficiency by reducing segmentation time and can be a valuable clinical tool, enhancing radiotherapy planning efficiency.

physics.med-ph↗

Explainable vertebral fracture analysis with uncertainty estimation using differentiable rule-based classification

We present a novel method for explainable vertebral fracture assessment (XVFA) in low-dose radiographs using deep neural networks, incorporating vertebra detection and keypoint localization with uncertainty estimates. We incorporate Genant's semi-quantitative criteria as a differentiable rule-based means of classifying both vertebra fracture grade and morphology. Unlike previous work, XVFA provides explainable classifications relatable to current clinical methodology, as well as uncertainty estimations, while at the same time surpassing state-of-the art methods with a vertebra-level sensitivity of 93% and end-to-end AUC of 97% in a challenging setting. Moreover, we compare intra-reader agreement with model uncertainty estimates, with model reliability on par with human annotators.

eess.IV↗

Deep conditional transformation models for survival analysis

An every increasing number of clinical trials features a time-to-event outcome and records non-tabular patient data, such as magnetic resonance imaging or text data in the form of electronic health records. Recently, several neural-network based solutions have been proposed, some of which are binary classifiers. Parametric, distribution-free approaches which make full use of survival time and censoring status have not received much attention. We present deep conditional transformation models (DCTMs) for survival outcomes as a unifying approach to parametric and semiparametric survival analysis. DCTMs allow the specification of non-linear and non-proportional hazards for both tabular and non-tabular data and extend to all types of censoring and truncation. On real and semi-synthetic data, we show that DCTMs compete with state-of-the-art DL approaches to survival analysis.

cs.LG↗

H&E-based Computational Biomarker Enables Universal EGFR Screening for Lung Adenocarcinoma

Lung cancer is the leading cause of cancer death worldwide, with lung adenocarcinoma being the most prevalent form of lung cancer. EGFR positive lung adenocarcinomas have been shown to have high response rates to TKI therapy, underlying the essential nature of molecular testing for lung cancers. Despite current guidelines consider testing necessary, a large portion of patients are not routinely profiled, resulting in millions of people not receiving the optimal treatment for their lung cancer. Sequencing is the gold standard for molecular testing of EGFR mutations, but it can take several weeks for results to come back, which is not ideal in a time constrained scenario. The development of alternative screening tools capable of detecting EGFR mutations quickly and cheaply while preserving tissue for sequencing could help reduce the amount of sub-optimally treated patients. We propose a multi-modal approach which integrates pathology images and clinical variables to predict EGFR mutational status achieving an AUC of 84% on the largest clinical cohort to date. Such a computational model could be deployed at large at little additional cost. Its clinical application could reduce the number of patients who receive sub-optimal treatments by 53.1% in China, and up to 96.6% in the US.

cs.CV↗

Depth resolved pencil beam radiography using AI -- a proof of principle study

AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission measurements. However, scatter - particularly Compton scatter, is characterizable. In this work we hypothesized that modern radiation sources and detectors paired with deep learning techniques can use scattered photon information constructively to resolve superimposed attenuators in planar x-ray imaging. METHODS: We simulated a monoenergetic x-ray imaging system consisting of a pencil beam x-ray source directed at an imaging target positioned in front of a high spatial- and energy-resolution detector array. The signal was analyzed by a convolutional neural network, and a description of scattering material along the axis of the beam was derived. The system was virtually designed/tested using Monte Carlo processing of simple phantoms consisting of 10 pseudo-randomly stacked air/bone/water materials, and the network was trained by solving a classification problem. RESULTS: The average accuracy of the material identification along the beam was 0.91 +- 0.01, with slightly higher accuracy towards the entrance/exit peripheral surfaces of the object. The average sensitivity and specificity was 0.91 and 0.95, respectively. CONCLUSIONS: Our work provides proof of principle that deep learning techniques can be used to analyze scattered photon patterns which can constructively contribute to the information content in radiography, here used to infer depth information in a traditional 2D planar setup. This principle, and our results, demonstrate that the information in Compton scattered photons may provide a basis for further development. The ability to scale performance to the clinic remains unexplored and requires further study.

physics.med-ph↗

Accelerating Prostate Diffusion Weighted MRI using Guided Denoising Convolutional Neural Network: Retrospective Feasibility Study

Purpose: To investigate feasibility of accelerating prostate diffusion-weighted imaging (DWI) by reducing the number of acquired averages and denoising the resulting image using a proposed guided denoising convolutional neural network (DnCNN). Materials and Methods: Raw data from the prostate DWI scans were retrospectively gathered (between July 2018 and July 2019) from six single-vendor MRI scanners. 118 data sets were used for training and validation (age: 64.3 +- 8 years) and 37 - for testing (age: 65.1 +- 7.3 years). High b-value diffusion-weighted (hb-DW) data were reconstructed into noisy images using two averages and reference images using all sixteen averages. A conventional DnCNN was modified into a guided DnCNN, which uses the low b-value DWI image as a guidance input. Quantitative and qualitative reader evaluations were performed on the denoised hb-DW images. A cumulative link mixed regression model was used to compare the readers scores. The agreement between the apparent diffusion coefficient (ADC) maps (denoised vs reference) was analyzed using Bland Altman analysis. Results: Compared to the DnCNN, the guided DnCNN produced denoised hb-DW images with higher peak signal-to-noise ratio and structural similarity index and lower normalized mean square error (p < 0.001). Compared to the reference images, the denoised images received higher image quality scores (p < 0.0001). The ADC values based on the denoised hb-DW images were in good agreement with the reference ADC values. Conclusion: Accelerating prostate DWI by reducing the number of acquired averages and denoising the resulting image using the proposed guided DnCNN is technically feasible.

eess.IV↗

Dynamic PET cardiac and parametric image reconstruction: a fixed-point proximity gradient approach using patch-based DCT and tensor SVD regularization

Our aim was to enhance visual quality and quantitative accuracy of dynamic positron emission tomography (PET)uptake images by improved image reconstruction, using sophisticated sparse penalty models that incorporate both 2D spatial+1D temporal (3DT) information. We developed two new 3DT PET reconstruction algorithms, incorporating different temporal and spatial penalties based on discrete cosine transform (DCT)w/ patches, and tensor nuclear norm (TNN) w/ patches, and compared to frame-by-frame methods; conventional 2D ordered subsets expectation maximization (OSEM) w/ post-filtering and 2D-DCT and 2D-TNN. A 3DT brain phantom with kinetic uptake (2-tissue model), and a moving 3DT cardiac/lung phantom was simulated and reconstructed. For the cardiac/lung phantom, an additional cardiac gated 2D-OSEM set was reconstructed. The structural similarity index (SSIM) and relative root mean squared error (rRMSE) relative ground truth was investigated. The image derived left ventricular (LV) volume for the cardiac/lung images was found by region growing and parametric images of the brain phantom were calculated. For the cardiac/lung phantom, 3DT-TNN yielded optimal images, and 3DT-DCT was best for the brain phantom. The optimal LV volume from the 3DT-TNN images was on average 11 and 55 percentage points closer to the true value compared to cardiac gated 2D-OSEM and 2D-OSEM respectively. Compared to 2D-OSEM, parametric images based on 3DT-DCT images generally had smaller bias and higher SSIM. Our novel methods that incorporate both 2D spatial and 1D temporal penalties produced dynamic PET images of higher quality than conventional 2D methods, w/o need for post-filtering. Breathing and cardiac motion were simultaneously captured w/o need for respiratory or cardiac gating. LV volumes were better recovered, and subsequently fitted parametric images were generally less biased and of higher quality.

cs.CV↗

DeepPET: A deep encoder-decoder network for directly solving the PET reconstruction inverse problem

Positron emission tomography (PET) is a cornerstone of modern radiology. The ability to detect cancer and metastases in whole body scans fundamentally changed cancer diagnosis and treatment. One of the main bottlenecks in the clinical application is the time it takes to reconstruct the anatomical image from the deluge of data in PET imaging. State-of-the art methods based on expectation maximization can take hours for a single patient and depend on manual fine-tuning. This results not only in financial burden for hospitals but more importantly leads to less efficient patient handling, evaluation, and ultimately diagnosis and treatment for patients. To overcome this problem we present a novel PET image reconstruction technique based on a deep convolutional encoder-decoder network, that takes PET sinogram data as input and directly outputs full PET images. Using realistic simulated data, we demonstrate that our network is able to reconstruct images >100 times faster, and with comparable image quality (in terms of root mean squared error) relative to conventional iterative reconstruction techniques.

cs.CV↗