Searcharxiv⌕ Search

arXiv subjects

Ilias Sachpazidis

Publications and source records attributed to Ilias Sachpazidis.

3 recordsLinked to original sources

MAAS-SFRThelper: An Integrated ESAPI Plugin for Structure Generation, Optimization, and Evaluation of Spatially Fractionated Radiation Therapy

Spatially fractionated radiation therapy (SFRT) planning requires three coordinated tasks: generation of high-dose sphere structures, position-aware optimization, and peak-valley dose ratio evaluation. We present MAAS-SFRThelper, a shared-source Eclipse Scripting Application Programming Interface (ESAPI) plugin that integrates structure generation, geometric-aware optimization, and peak-valley dose ratio evaluation for SFRT into a single workflow inside Varian's Eclipse treatment planning system. The plugin exposes five task-oriented tabs sharing common services for sphere extraction and objective creation. The SphereLattice tab generates sphere lattices using five placement patterns. The Optimization tab searches over candidate lattice positions using a four-metric geometric surrogate score and triggers VMAT optimization and dose calculation. The Evaluation tab implements four analysis modes; its three-dimensional peak-valley classification recovers sphere centers from the lattice structure through a geometric extraction pipeline rather than relying on dose thresholds. We validated all functionality on digital phantoms against analytic ground truth. The plugin is distributed as source code under the Varian Limited Use Software License Agreement. Source code and documentation are publicly available on GitHub.

physics.med-ph↗

Prediction of Local Failure after Stereotactic Radiotherapy in Melanoma Brain Metastases Using Ensemble Learning on Clinical, Dosimetric, and Radiomic Data

Background: This study aimed to predict lesion-specific outcomes after stereotactic radiotherapy (SRT) in patients with brain metastases from malignant melanoma (MBM), using clinical, dosimetric, and pretherapeutic MRI data. Methods: In this multicenter retrospective study, 517 MBM from 130 patients treated with single-fraction or hypofractionated SRT at three centers were analyzed. From contrast-enhanced T1-weighted MRI, 1576 radiomic features (RF) were extracted per lesion - 788 from the gross tumor volume (GTV) and 788 from a 3 mm peritumoral margin. Clinical, dosimetric and RF data from one center were used for feature selection and model development via nested cross-validation employing an ensemble learning approach; external validation used data from the other two centers. Results: Local failure occurred in 72/517 lesions (13.9%). Predictive models based on clinical data, RF, or a combination of both achieved c-indices of 0.60 +/- 0.15, 0.65 +/- 0.11, and 0.65 +/- 0.12, respectively. RF-based models outperformed the clinical models; dosimetric data alone were not predictive. Most predictive RF originated from the peritumoral margin (92%) versus GTV (76%). On the first external dataset, all models performed similarly (c-index: 0.60-0.63), but generalization was poor on the second (c-index < 0.50), likely due to differences in patient characteristics and imaging protocols. Conclusions: Pretherapeutic MRI features, particularly from the peritumoral region, show promise for predicting lesion-specific outcomes in MBM after SRT. Their consistent contribution suggests biologically relevant information that may support individualized treatment planning. Combined with clinical data, these markers offer prognostic insight, though generalizability remains limited by data heterogeneity.

physics.med-ph↗

The use of deep learning in interventional radiotherapy (brachytherapy): a review with a focus on open source and open data

Deep learning advanced to one of the most important technologies in almost all medical fields. Especially in areas, related to medical imaging it plays a big role. However, in interventional radiotherapy (brachytherapy) deep learning is still in an early phase. In this review, first, we investigated and scrutinised the role of deep learning in all processes of interventional radiotherapy and directly related fields. Additionally we summarised the most recent developments. To reproduce results of deep learning algorithms both source code and training data must be available. Therefore, a second focus of this work was on the analysis of the availability of open source, open data and open models. In our analysis, we were able to show that deep learning plays already a major role in some areas of interventional radiotherapy, but is still hardly presented in others. Nevertheless, its impact is increasing with the years, partly self-propelled but also influenced by closely related fields. Open source, data and models are growing in number but are still scarce and unevenly distributed among different research groups. The reluctance in publishing code, data and models limits reproducibility and restricts evaluation to mono-institutional datasets. Summarised, deep learning will change positively the workflow of interventional radiotherapy but there is room for improvement when it comes to reproducible results and standardised evaluation methods.

physics.med-ph↗