SearcharxivSearch

arXiv subjects

Ilker Hacihaliloglu

Publications and source records attributed to Ilker Hacihaliloglu.

At least 19 recordsLinked to original sources

Which Pretext Task Transfers? Self-Supervised Pretraining Objectives for Lung Ultrasound

Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound (LUS). Contrastive learning, masked reconstruction, and joint-embedding predictive architectures (JEPA) differ in the space in which their targets are defined, yet existing ultrasound studies compare them under different corpora, backbones, and evaluation protocols. We compare these three objective families using the same encoder backbone, pretraining corpus, optimisation schedule, and frozen-evaluation protocol. Encoders are pretrained on COVID-BLUeS LUS videos and evaluated with linear, $k$NN, and attentive probes at 5\%, 10\%, 50\%, and 100\% label budgets. Evaluation is performed on POCUS using patient-level five-fold cross-validation and on the independently acquired Mendeley-Uganda dataset, which is excluded from both pretraining and probe fitting. At the full label budget under linear probing, VideoMAE and V-JEPA achieve $66.5 \pm 13.1$ and $65.4 \pm 11.7$ balanced accuracy on POCUS, while MoCo achieves $42.1 \pm 1.2$. On Mendeley-Uganda, the ranking reverses: MoCo performs best at $62.7 \pm 1.0$, followed by VideoMAE at $53.8 \pm 2.8$, while V-JEPA falls near chance at $35.1 \pm 4.9$. These results show that POCUS probe accuracy alone does not identify the objective that transfers best across datasets. We also outline planned representation-level analyses to examine this reversal. Code is publicly available at https://github.com/moeinheidari7829/LUSVideoSSL.

cs.CV

Echo-E$^3$Net: Efficient Endocardial Spatio-Temporal Network for Ejection Fraction Estimation

Left ventricular ejection fraction (LVEF) is a primary marker of cardiac function. However, routine estimation from endocardial measurements requires manual delineation at end-diastole (ED) and end-systole (ES), a process that is time-consuming and subject to inter-observer variability. Reliable automation is especially valuable for point-of-care ultrasound (POCUS), where computational resources are limited and acquisition quality varies. We propose Echo-E$^3$Net, an anatomy-guided spatio-temporal network that explicitly embeds cardiac anatomy into LVEF prediction. A dual-phase Endocardial Border Detector (E$^2$CBD) uses phase-specific cross-attention to localize ED/ES endocardial landmarks and produce phase-aware landmark embeddings, while an Endocardial Feature Aggregator (E$^2$FA) fuses these embeddings with global statistical descriptors of deep feature maps to refine EF regression. Training is guided by a lightweight geometric loss that uses ED and ES endocardial landmarks to regularize EF prediction. On EchoNet-Dynamic and a PSAX subset of EchoNet-Pediatric, Echo-E$^3$Net attains competitive performance using only 1.55M parameters and 8.05 GFLOPs, an order-of-magnitude compute reduction versus recent baselines, supporting real-time deployment. Our code is publicly available at https://github.com/moeinheidari7829/Echo-E3Net.

eess.IV

WaRA: Wavelet Low-Rank Adaptation for Medical Image Classification

Adapting large pretrained vision models to medical image classification is often limited by memory, computation, and task-specific specializations. Parameter-efficient fine-tuning (PEFT) methods like LoRA reduce this cost by learning low-rank updates, but operating directly in feature space can struggle to capture the localized, multi-scale features common in medical imaging. We propose WaRA, a wavelet-structured adaptation module that performs low-rank adaptation in a wavelet domain. WaRA reshapes patch tokens into a spatial grid, applies a fixed discrete wavelet transform, updates subband coefficients using a shared low-rank adapter, and reconstructs the additive update through an inverse wavelet transform. This design provides a compact trainable interface while biasing the update toward both coarse structure and fine detail. For extremely low-resource settings, we introduce Tiny-WaRA, which further reduces trainable parameters by learning only a small set of coefficients in a fixed basis derived from the pretrained weights through a truncated SVD. Experiments on medical image classification across four modalities and datasets demonstrate that WaRA consistently improves performance over strong PEFT baselines, while retaining a favorable efficiency profile. Our code is publicly available at https://github.com/moeinheidari7829/WaRA.

cs.CV

Echo-CoPilot: A Multiple-Perspective Agentic Framework for Reliable Echocardiography Interpretation

Echocardiography interpretation requires integrating multi-view temporal evidence with quantitative measurements and guideline-grounded reasoning, yet existing foundation-model pipelines largely solve isolated subtasks and fail when tool outputs are noisy or values fall near clinical cutoffs. We propose Echo-CoPilot, an end-to-end agentic framework that combines a multi-perspective workflow with knowledge-graph-guided measurement selection. Echo-CoPilot runs three independent ReAct-style agents, structural, pathological, and quantitative, that invoke specialized echocardiography tools to extract parameters while querying EchoKG to determine which measurements are required for the clinical question and which should be avoided. A self-contrast language model then compares the evidence-grounded perspectives, generates a discrepancy checklist, and re-queries EchoKG to apply the appropriate guideline thresholds and resolve conflicts, reducing hallucinated measurement selection and borderline flip-flops. On MIMICEchoQA, Echo-CoPilot provides higher accuracy compared to SOTA baselines and, under a stochasticity stress test, achieves higher reliability through more consistent conclusions and fewer answer changes across repeated runs. Our code is publicly available at https://github.com/moeinheidari7829/Echo-CoPilot.

cs.AI

MaLViL: Multi-axis Low-rank Vision-LSTM for Medical Image Segmentation

Vision-LSTM (ViL) enables efficient global modeling, but its cost still scales with the number of spatial tokens, so existing segmenters confine ViL to a coarse bottleneck and lose fine anatomical detail. Rasterizing 2D features into a 1D sequence further breaks adjacency across the orthogonal scan axis. We propose MaLViL, a Multi-axis Low-rank Vision-LSTM network that extends ViL across decoder resolutions. Bidirectional low-rank ViL (Bi-LRViL) reasons on a compact orthonormal subspace and preserves detail through an orthogonal residual; scale-aware SaLViL restores cross-axis neighbors before serialization; and a Cross-Directional Mixer (CDM) fuses orthogonal horizontal and vertical traversal paths. Statistics-Guided Skip Modulation (SGSM) further retains boundary cues in encoder skips. On skin-lesion, ultrasound, and multi-organ CT benchmarks, MaLViL achieves competitive or state-of-the-art segmentation accuracy, while reducing ViL operator memory by up to $83\times$ at fine decoder resolutions. Code is available at: https://github.com/xmindflow/malvil.

cs.CV

Analyzing Image Encoder Choices and Graph Homophily in GCN Frameworks for Breast Ultrasound Classification

Breast ultrasound is widely used for screening, yet automated analysis remains challenging due to speckle noise, acquisition variability, and weak separation of benign and malignant cases in standard ultrasound imaging. Graph convolutional networks (GCNs) have recently emerged as a promising approach by leveraging relationships among similar patient samples. However, it remains unclear how the choice of image encoder influences graph construction and downstream classification performance. In this work, we systematically evaluate five image encoders spanning convolutional and transformer-based architectures for GCN-based breast ultrasound classification. Image embeddings are used to construct cosine similarity k-nearest-neighbor graphs, which are classified using a single-layer GCN with a linear classification head. Across three patientwise cross-validation folds, higher-capacity encoders consistently improve graph homophily and downstream classification performance, yielding gains in accuracy, AUC, sensitivity, specificity, and F1-score. Moreover, test-set graph homophily exhibits a strong linear correlation with classification accuracy, with higher-capacity encoders consistently occupying the high-homophily, high-accuracy region suggesting that encoder-driven improvements in graph structure are a key mechanism underlying the observed performance gains. These findings establish encoder selection as a critical factor in graph-based breast ultrasound classification and identify graph homophily as a key indicator linking representation quality to downstream classification performance.

eess.IV

Learning from Complementary Ultrasound Representations for Liver Disease Classification

Differentiating non-alcoholic steatohepatitis (NASH) from non-alcoholic fatty liver disease (NAFLD) using ultrasound remains challenging due to subtle tissue alterations and the limited information available in conventional B-mode imaging. In this work, we investigate whether complementary ultrasound representations derived from the same acquisition can improve NASH versus NAFLD classification. Specifically, we combine conventional B-mode ultrasound with physics-guided and local phase-based image representations and evaluate their effectiveness using self-supervised masked autoencoders (MAEs) and graph convolutional networks (GCNs). Experiments were conducted on a multi-site Mayo Clinic cohort consisting of 2,547 liver ultrasound scans from 125 patients. Compared with conventional B-mode ultrasound alone, complementary ultrasound representations consistently improved classification performance, yielding gains of up to 32.4% in accuracy and 91.2% in F1-score. Furthermore, performance improvements were consistently observed across age groups, sex, race, ethnicity,and acquisition sites.

cs.CV

VAMPS: Visual-Assisted Mathematical Problem Solving Benchmark

Multimodal large language models are increasingly capable of complex reasoning, yet their performance often degrades when they must externalize a problem through a tool and then reason over the tool's output, specifically when they rely on visual aids. This gap is especially important because real engineering and scientific workflows often rely on visualization tools for analysis, validation, and decision-making. To study this discrepancy, we introduce VAMPS (Visual-Assisted Mathematical Problem Solving), a benchmark for graph-assisted mathematics. VAMPS contains 1,168 multimodal, bilingual multiple-choice question-answer pairs drawn from Iranian University Entrance Exam algebra and calculus problems and expanded with human-reviewed LLM-generated synthetic variants, all selected so that plotting provides a natural solution strategy by revealing intersections, extrema, asymptotes, etc. Designed for both benchmarking and diagnosis, VAMPS goes beyond prior multimodal benchmarks that primarily evaluate reasoning over fixed visual inputs by testing whether a model can benefit from constructing a useful graph and grounding its answer in the resulting visualization. Overall, we found that across a diverse set of models, direct analytical solving surprisingly outperforms tool-enabled visual solving, even on problems where plotting is a natural strategy.

cs.AI

XTinyU-Net: Training-Free U-Net Scaling via Initialization-Time Sensitivity

While U-Net architectures remain the gold standard for medical image segmentation, their deployment in resource-constrained environments demands aggressive model compression. However, finding an optimally efficient configuration is computationally prohibitive, typically requiring exhaustive train-and-evaluate cycles to find the smallest model that maintains peak performance. In this paper, we introduce a training-free selection framework to automatically identify ultralightweight, dataset-specific U-Net configurations directly at initialization. We observe that systematically scaling down U-Net channel width induces a sharp transition from a stable performance plateau to representational capacity collapse. To pinpoint this boundary without training, we propose a Jacobian-based sensitivity metric that scores discrete, width-capped U-Net variants using a small set of unlabeled images. By analyzing the total variation of this sensitivity curve, we isolate the smallest stable configuration, which we denote as XTinyU-Net. Evaluated across six diverse medical datasets within the nnU-Net framework, XTinyU-Net achieves segmentation accuracy comparable to the heavy nnU-Net baseline with 400x-1600x fewer parameters, and outperforms contemporary lightweight architectures while utilizing 5x-72x fewer parameters. Code is publicly accessible on https://github.com/alvinkimbowa/nntinyunet.git.

eess.IV

MonoUNet: A Robust Tiny Neural Network for Automated Knee Cartilage Segmentation on Point-of-Care Ultrasound Devices

Objective: To develop a robust and compact deep learning model for automated knee cartilage segmentation on point-of-care ultrasound (POCUS) devices. Methods: We propose MonoUNet, a novel, highly compact segmentation model consisting of (i) an aggressively reduced U-Net backbone, (ii) a trainable monogenic block that extracts multi-scale local phase features from the input, and (iii) a gating mechanism that injects these features into the encoder stages to reduce sensitivity to variations in ultrasound image appearance. MonoUNet segmentation performance was evaluated on a multi-site, multi-device knee cartilage ultrasound dataset using Dice score and mean average surface distance (MASD). Agreement between MonoUNet and manual cartilage outcomes (thickness and echo intensity) was assessed using Bland-Altman analysis with 95% limits of agreement, and reliability was assessed using intraclass correlation coefficient (ICC$_{2,k}$). Results: Overall, MonoUNet outperformed existing lightweight segmentation models, with average Dice scores ranging from 92.62% to 94.82% and MASD values between 0.133 mm and 0.254 mm. MonoUNet reduces the number of parameters by 10x--700x and computational cost by 14x--2000x relative to existing lightweight models. MonoUNet cartilage outcomes showed excellent reliability and agreement with the manual outcomes: intraclass correlation coefficients (ICC$_{2,k})$=0.96 and bias=2.00% (0.047 mm) for average thickness, and ICC$_{2,k}$=0.99 and bias=0.80% (0.328 a.u.) for echo intensity. Conclusion: Incorporating trainable local phase features improves the robustness of highly compact neural networks for knee cartilage segmentation across varying acquisition settings and could support scalable ultrasound-based assessment and monitoring of knee osteoarthritis using POCUS devices. The code is publicly available at https://github.com/alvinkimbowa/monounet.

eess.IV

A Clinically Anchored Radiomics Dictionary for Explainable TI-RADS-Based Thyroid Nodule Classification in Ultrasound; Dictionary Version TU1.0

Artificial intelligence based radiomics models for thyroid ultrasound (US) often achieve strong diagnostic performance but remain difficult to interpret, limiting clinical trust and adoption. We developed and validated an interpretable radiomic feature (RF) framework for thyroid nodule classification by linking quantitative US features to the Thyroid Imaging Reporting and Data System (TI-RADS) semantic lexicon through a clinically grounded radiomics dictionary. The dictionary mapped TI-RADS categories, including composition, echogenicity, shape, margin, and echogenic foci, to Image Biomarker Standardization Initiative compliant RFs extracted from two-dimensional US images. Relationships were defined through expert consensus and examined using Shapley Additive Explanations (SHAP). Three multicenter datasets were combined, yielding 5,542 nodules. A total of 107 RFs were extracted using PyRadiomics and normalized with min-max scaling. For benign versus malignant classification, 27 feature selection methods were paired with 25 classifiers and evaluated using stratified five-fold cross-validation on 70% of the data, followed by testing on the remaining 30%. Robust model selection used a stability-aware composite score combining mean performance and variability across balanced accuracy, precision, recall, F1-score, and ROC-AUC. The proposed dictionary enabled direct interpretation of radiomic signatures in TI-RADS terms. The best model, Select-From-Model based on logistic regression with Extra-Trees, achieved a test ROC-AUC of 0.941 +/- 0.005. SHAP analysis showed that texture heterogeneity was the dominant malignancy signal, with gray level run length matrix non-uniformity, intensity dispersion, and kurtosis aligning with high-risk TI-RADS descriptors. These findings support transparent and clinically meaningful thyroid nodule risk stratification from US.

physics.med-ph

When Minor Edits Matter: LLM-Driven Prompt Attack for Medical VLM Robustness in Ultrasound

Ultrasound is widely used in clinical practice due to its portability, cost-effectiveness, safety, and real-time imaging capabilities. However, image acquisition and interpretation remain highly operator dependent, motivating the development of robust AI-assisted analysis methods. Vision-language models (VLMs) have recently demonstrated strong multimodal reasoning capabilities and competitive performance in medical image analysis, including ultrasound. However, emerging evidence highlights significant concerns about their trustworthiness. In particular, adversarial robustness is critical because Med-VLMs operate via natural-language instructions, rendering prompt formulation a realistic and practically exploitable point of vulnerability. Small variations (typos, shorthand, underspecified requests, or ambiguous wording) can meaningfully shift model outputs. We propose a scalable adversarial evaluation framework that leverages a large language model (LLM) to generate clinically plausible adversarial prompt variants via "humanized" rewrites and minimal edits that mimic routine clinical communication. Using ultrasound multiple-choice question answering benchmarks, we systematically assess the vulnerability of SOTA Med-VLMs to these attacks, examine how attacker LLM capacity influences attack success, analyze the relationship between attack success and model confidence, and identify consistent failure patterns across models. Our results highlight realistic robustness gaps that must be addressed for safe clinical translation. Code will be released publicly following the review process.

cs.CV

Representation-Level Adversarial Regularization for Clinically Aligned Multitask Thyroid Ultrasound Assessment

Thyroid ultrasound is the first-line exam for assessing thyroid nodules and determining whether biopsy is warranted. In routine reporting, radiologists produce two coupled outputs: a nodule contour for measurement and a TI-RADS risk category based on sonographic criteria. Yet both contouring style and risk grading vary across readers, creating inconsistent supervision that can degrade standard learning pipelines. In this paper, we address this workflow with a clinically guided multitask framework that jointly predicts the nodule mask and TI-RADS category within a single model. To ground risk prediction in clinically meaningful evidence, we guide the classification embedding using a compact TI-RADS aligned radiomics target during training, while preserving complementary deep features for discriminative performance. However, under annotator variability, naive multitask optimization often fails not because the tasks are unrelated, but because their gradients compete within the shared representation. To make this competition explicit and controllable, we introduce RLAR, a representation-level adversarial gradient regularizer. Rather than performing parameter-level gradient surgery, RLAR uses each task's normalized adversarial direction in latent space as a geometric probe of task sensitivity and penalizes excessive angular alignment between task-specific adversarial directions. On a public TI-RADS dataset, our clinically guided multitask model with RLAR consistently improves risk stratification while maintaining segmentation quality compared to single-task training and conventional multitask baselines. Code and pretrained models will be released.

cs.CV

SL$^{2}$A-INR: Single-Layer Learnable Activation for Implicit Neural Representation

Implicit Neural Representation (INR), leveraging a neural network to transform coordinate input into corresponding attributes, has recently driven significant advances in several vision-related domains. However, the performance of INR is heavily influenced by the choice of the nonlinear activation function used in its multilayer perceptron (MLP) architecture. To date, multiple nonlinearities have been investigated, but current INRs still face limitations in capturing high-frequency components and diverse signal types. We show that these challenges can be alleviated by introducing a novel approach in INR architecture. Specifically, we propose SL$^{2}$A-INR, a hybrid network that combines a single-layer learnable activation function with an MLP that uses traditional ReLU activations. Our method performs superior across diverse tasks, including image representation, 3D shape reconstruction, and novel view synthesis. Through comprehensive experiments, SL$^{2}$A-INR sets new benchmarks in accuracy, quality, and robustness for INR. Our Code is publicly available on~\href{https://github.com/Iceage7/SL2A-INR}{\textcolor{magenta}{GitHub}}.

cs.CV

Enhancement Without Contrast: Stability-Aware Multicenter Machine Learning for Glioma MRI Imaging

Gadolinium-based contrast agents (GBCAs) are central to glioma imaging but raise safety, cost, and accessibility concerns. Predicting contrast enhancement from non-contrast MRI using machine learning (ML) offers a safer alternative, as enhancement reflects tumor aggressiveness and informs treatment planning. Yet scanner and cohort variability hinder robust model selection. We propose a stability-aware framework to identify reproducible ML pipelines for multicenter prediction of glioma MRI contrast enhancement. We analyzed 1,446 glioma cases from four TCIA datasets (UCSF-PDGM, UPENN-GB, BRATS-Africa, BRATS-TCGA-LGG). Non-contrast T1WI served as input, with enhancement derived from paired post-contrast T1WI. Using PyRadiomics under IBSI standards, 108 features were extracted and combined with 48 dimensionality reduction methods and 25 classifiers, yielding 1,200 pipelines. Rotational validation was trained on three datasets and tested on the fourth. Cross-validation prediction accuracies ranged from 0.91 to 0.96, with external testing achieving 0.87 (UCSF-PDGM), 0.98 (UPENN-GB), and 0.95 (BRATS-Africa), with an average of 0.93. F1, precision, and recall were stable (0.87 to 0.96), while ROC-AUC varied more widely (0.50 to 0.82), reflecting cohort heterogeneity. The MI linked with ETr pipeline consistently ranked highest, balancing accuracy and stability. This framework demonstrates that stability-aware model selection enables reliable prediction of contrast enhancement from non-contrast glioma MRI, reducing reliance on GBCAs and improving generalizability across centers. It provides a scalable template for reproducible ML in neuro-oncology and beyond.

cs.CV

Handcrafted vs. Deep Radiomics vs. Fusion vs. Deep Learning: A Comprehensive Review of Machine Learning -Based Cancer Outcome Prediction in PET and SPECT Imaging

Machine learning (ML), including deep learning (DL) and radiomics-based methods, is increasingly used for cancer outcome prediction with PET and SPECT imaging. However, the comparative performance of handcrafted radiomics features (HRF), deep radiomics features (DRF), DL models, and hybrid fusion approaches remains inconsistent across clinical applications. This systematic review analyzed 226 studies published from 2020 to 2025 that applied ML to PET or SPECT imaging for outcome prediction. Each study was evaluated using a 59-item framework covering dataset construction, feature extraction, validation methods, interpretability, and risk of bias. We extracted key details including model type, cancer site, imaging modality, and performance metrics such as accuracy and area under the curve (AUC). PET-based studies (95%) generally outperformed those using SPECT, likely due to higher spatial resolution and sensitivity. DRF models achieved the highest mean accuracy (0.862), while fusion models yielded the highest AUC (0.861). ANOVA confirmed significant differences in performance (accuracy: p=0.0006, AUC: p=0.0027). Common limitations included inadequate handling of class imbalance (59%), missing data (29%), and low population diversity (19%). Only 48% of studies adhered to IBSI standards. These findings highlight the need for standardized pipelines, improved data quality, and explainable AI to support clinical integration.

physics.med-ph

Radiological and Biological Dictionary of Radiomics Features: Addressing Understandable AI Issues in Personalized Breast Cancer; Dictionary Version BM1.0

Radiomics-based AI models show promise for breast cancer diagnosis but often lack interpretability, limiting clinical adoption. This study addresses the gap between radiomic features (RF) and the standardized BI-RADS lexicon by proposing a dual-dictionary framework. First, a Clinically-Informed Feature Interpretation Dictionary (CIFID) was created by mapping 56 RFs to BI-RADS descriptors (shape, margin, internal enhancement) through literature and expert review. The framework was applied to classify triple-negative breast cancer (TNBC) versus non-TNBC using dynamic contrast-enhanced MRI from a multi-institutional cohort of 1,549 patients. We trained 27 machine learning classifiers with 27 feature selection methods. SHapley Additive exPlanations (SHAP) were used to interpret predictions and generate a complementary Data-Driven Feature Interpretation Dictionary (DDFID) for 52 additional RFs. The best model, combining Variance Inflation Factor (VIF) selection with Extra Trees Classifier, achieved an average cross-validation accuracy of 0.83. Key predictive RFs aligned with clinical knowledge: higher Sphericity (round/oval shape) and lower Busyness (more homogeneous enhancement) were associated with TNBC. The framework confirmed known imaging biomarkers and uncovered novel, interpretable associations. This dual-dictionary approach (BM1.0) enhances AI model transparency and supports the integration of RFs into routine breast cancer diagnosis and personalized care.

physics.comp-ph

Influence of High-Performance Image-to-Image Translation Networks on Clinical Visual Assessment and Outcome Prediction: Utilizing Ultrasound to MRI Translation in Prostate Cancer

Purpose: This study examines the core traits of image-to-image translation (I2I) networks, focusing on their effectiveness and adaptability in everyday clinical settings. Methods: We have analyzed data from 794 patients diagnosed with prostate cancer (PCa), using ten prominent 2D/3D I2I networks to convert ultrasound (US) images into MRI scans. We also introduced a new analysis of Radiomic features (RF) via the Spearman correlation coefficient to explore whether networks with high performance (SSIM>85%) could detect subtle RFs. Our study further examined synthetic images by 7 invited physicians. As a final evaluation study, we have investigated the improvement that are achieved using the synthetic MRI data on two traditional machine learning and one deep learning method. Results: In quantitative assessment, 2D-Pix2Pix network substantially outperformed the other 7 networks, with an average SSIM~0.855. The RF analysis revealed that 76 out of 186 RFs were identified using the 2D-Pix2Pix algorithm alone, although half of the RFs were lost during the translation process. A detailed qualitative review by 7 medical doctors noted a deficiency in low-level feature recognition in I2I tasks. Furthermore, the study found that synthesized image-based classification outperformed US image-based classification with an average accuracy and AUC~0.93. Conclusion: This study showed that while 2D-Pix2Pix outperformed cutting-edge networks in low-level feature discovery and overall error and similarity metrics, it still requires improvement in low-level feature performance, as highlighted by Group 3. Further, the study found using synthetic image-based classification outperformed original US image-based methods.

eess.IV