6 recordsLinked to original sources

Scintillation Properties of a Stilbene Crystal for Low-Mass Dark Matter Searches

Direct searches for low-mass WIMPs require sensitivity to low-energy nuclear recoils. Hydrogen-containing targets offer favorable scattering kinematics because low-mass WIMPs can transfer a larger fraction of their kinetic energy to hydrogen nuclei than to heavier nuclei. Trans-stilbene (t-stilbene) is a hydrogen-rich organic crystal that combines this kinematic advantage with efficient scintillation and pulse-shape discrimination (PSD).In this work, we characterize the scintillation decay behavior and effective light yield of a solution-grown t-stilbene crystal to evaluate its suitability for dark matter detection. The detector consists of a cylindrical crystal approximately 1.1 cm in diameter and 1.1 cm in length, optically coupled at opposite ends to two Hamamatsu R12669 photomultiplier tubes. The scintillation waveforms are described by a triple-exponential decay model, yielding fraction-weighted decay time constants of $8.3 \pm 0.2$ ns (fast), $20.1 \pm 0.3$ ns (medium), and $74.2 \pm 1.1$ ns (slow). The effective light yield, determined using a 59.54 keV $\gamma$ ray from an $^{241}$Am source, is $3.37 \pm 0.02$ photoelectrons per keV.These measurements establish the baseline performance of the detector and support further evaluation of t-stilbene as a target material for rare-event and low-mass dark matter searches.

physics.ins-det

Development and Initial Performance of an Upgraded NaI(Tl) Crystal Encapsulation for COSINE-100U

The COSINE-100 experiment was designed to test the DAMA/LIBRA annual-modulation claim using low-background NaI(Tl) detectors. For the COSINE-100U upgrade, we developed a new crystal-encapsulation system to increase light-collection efficiency while preserving long-term detector stability, thereby improving sensitivity to low-mass dark matter. The upgraded design eliminates the quartz optical windows used in COSINE-100 and directly couples the photomultiplier tubes (PMTs) to the crystal end faces through 2-mm-thick silicone optical pads, thereby reducing the number of optical interfaces. For the larger crystals, the crystal edges were beveled to guide scintillation light more efficiently onto 3-inch high-quantum-efficiency PMTs. The performance study uses 2462~h (102.6~days) of room-temperature COSINE-100U data and, for direct background comparisons, reference COSINE-100 data acquired near the end of operation. 698~h (29.1~days) of COSINE-100 data acquired near the end of operation in March 2023. All eight crystals showed higher light yields than in COSINE-100, with values ranging from 15.8 to 27.7~p.e./keV; six crystals exceeded 20~p.e./keV. The measured bulk-$\alpha$ rates were lower than the COSINE-100 values and consistent with the expected time evolution of internal $^{210}$Pb, while the 1--2-MeV surface-$\alpha$ rates were substantially reduced. The upgrade also restored two crystals that had previously been excluded from the COSINE-100 physics analysis because of poor optical performance. Independent validation tests demonstrated that the encapsulation remains mechanically robust and optically stable during long-term immersion in liquid scintillator at low temperature. This paper presents the encapsulation design, the room-temperature detector performance, and the reduction in surface-related backgrounds achieved at the Yemilab facility.

physics.ins-det

Validation of the COSINE-100U NaI(Tl) Encapsulation for Low-Temperature Operation in Liquid Scintillator

The COSINE-100U (upgrade) will enhance the sensitivity of the COSINE-100 dark matter search by operating the detector array immersed in liquid scintillator (LS) at $-30^oC$. To validate the detector design for these conditions, we constructed a module using the COSINE-100U encapsulation and performed a dedicated long-term stability study. The module was first monitored at room temperature for ~110 days in air, followed by a one-week immersion in LAB-based LS to verify initial compatibility. Upon confirming stable optical performance, the temperature was lowered to $-33^oC$. During approximately 150 days of continuous operation at low temperature, we observed no degradation in performance. These results demonstrate the chemical and mechanical robustness of the encapsulation, confirming its suitability for the COSINE-100U physics run.

physics.ins-det

New Constraints on Axion-Like Particles with the NEON Detector at a Nuclear Reactor

We report new constraints on axion-like particles (ALPs) using data from the NEON experiment, which features a 16.7 kg of NaI(Tl) target located 23.7 meters from a 2.8 GW thermal power nuclear reactor. Analyzing a total exposure of 3063 kg$\cdot$days, with 1596 kg$\cdot$days during reactor-on and 1467 kg$\cdot$days during reactor-off periods, we compared energy spectra to search for ALP-induced signals. No significant signal was observed, enabling us to set exclusion limits at the 95\% confidence level. These limits probe previously unexplored regions of the ALP parameter space, particularly for axion mass ($m_a$) near $1$ MeV/c$^2$. For ALP-photon coupling (${g_{a\gamma}}$), limits reach as low as 6.24$\times$ 10$^{-6}$ GeV$^{-1}$ at $m_a$ = 3.0 MeV/c$^2$, while for ALP-electron coupling (${g_{ae}}$), limits reach 4.95$\times$ 10$^{-8}$ at $m_a$ = 1.02 MeV/c$^2$. This work demonstrates the potential for future reactor experiments to probe unexplored ALP parameter space.

hep-ex

Performance of an ultra-pure NaI(Tl) detector produced by an indigenously-developed purification method and crystal growth for the COSINE-200 experiment

The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors to test the results from the DAMA/LIBRA experiment, which claims to have observed dark matter. However, since the background of the NaI(Tl) crystals used in the COSINE-100 experiment is 2-3 times higher than that in the DAMA detectors, no conclusion regarding the claimed observation from the DAMA/LIBRA experiment could be reached. Therefore, we plan to upgrade the current COSINE-100 experiment to the next phase, COSINE-200, by using ultra-low background NaI(Tl) detectors. The basic principle was already proved with the commercially available Astro-grade NaI powder from Sigma-Aldrich company. However, we have developed a mass production process of ultra-pure NaI powder at the Center for Underground Physics (CUP) of the Institute for Basic Science (IBS), Korea, using the direct purification of the raw NaI powder. We plan to produce more than 1,000 kg of ultra-pure powder for the COSINE200 experiment. With our crystal grower installed at CUP, we have successfully grown a low-background crystal using our purification technique for the NaI powder. We have assembled a low-background NaI(Tl) detector. In this article, we report the performance of this ultra-pure NaI(Tl) crystal detector produced at IBS, Korea.

physics.ins-det

NaI(Tl) crystal scintillator encapsulated in two organic-scintillator layers with pulse shape data analysis

Thallium-doped sodium iodide (NaI(Tl)) crystals are widely used in radiation detection applications, from gamma-ray spectroscopy to particle dark matter searches. However, if the crystal is exposed to relative humidity of even a few percent, its light emission degrades, making the crystal impractical as a detector. Surrounding the crystal with organic scintillators not only protects the surface of the crystal from humid air but also offers a new capability to tag backgrounds such as external gamma rays and surface contaminations. We developed a detector that is constructed by fully encasing a NaI(Tl) crystal in a plastic scintillator and then immersing the plastic-crystal assembly in liquid scintillator. Using data collected from this triple phoswich detector, a pulse shape analysis is able to identify the various radiation signals from the three scintillators. Additionally, we find that the crystal's emission quality is maintained for a month.

physics.ins-det