SearcharxivSearch

arXiv subjects

Ingo Nosske

Publications and source records attributed to Ingo Nosske.

6 recordsLinked to original sources

Interspecies clock comparison below $5 \times 10^{-18}$ uncertainty with a transportable clock

We report a measurement of the optical frequency ratio between the $^2\mathrm{S}_{1/2}(F=0)$--${^2\mathrm{F}_{7/2}(F=3)}$ electric-octupole (E3) transition of $^{171}$Yb$^{+}$ and the $^1\mathrm{S}_0$--${^3\mathrm{P}_0}$ transition of $^{87}$Sr, $\nu_{\mathrm{Yb}^{+}}/\nu_\mathrm{Sr} = 1.495\,991\,618\,544\,900\,588\,1(65)$. Reaching a fractional uncertainty of $4.3 \times 10^{-18}$, this result improves upon the previous best by more than a factor of three and is among the few that meet the requirements for interspecies clock comparisons specified by the roadmap towards the redefinition of the SI second. The comparison is between a transportable optical lattice clock and a stationary single-ion clock. It spans a period of nearly two years, during which the transportable clock was intermittently operated off-campus. The ratio was reproducibly measured during four separate campaigns, which are consistent within their statistical uncertainties. The results demonstrate reproducible $10^{-18}$ level operation of the transportable clock and thus validate its application for chronometric geodesy and as a transfer standard for inter-institute clock comparisons, e.g., in the absence of optical fiber links.

physics.atom-ph

International comparison of optical frequencies with transportable optical lattice clocks

Optical clocks have improved their frequency stability and estimated accuracy by more than two orders of magnitude over the best caesium microwave clocks that realise the SI second. Accordingly, an optical redefinition of the second has been widely discussed, prompting a need for the consistency of optical clocks to be verified worldwide. While satellite frequency links are sufficient to compare microwave clocks, a suitable method for comparing high-performance optical clocks over intercontinental distances is missing. Furthermore, remote comparisons over frequency links face fractional uncertainties of a few $10^{-18}$ due to imprecise knowledge of each clock's relativistic redshift, which stems from uncertainty in the geopotential determined at each distant location. Here, we report a landmark campaign towards the era of optical clocks, where, for the first time, state-of-the-art transportable optical clocks from Japan and Europe are brought together to demonstrate international comparisons that require neither a high-performance frequency link nor information on the geopotential difference between remote sites. Conversely, the reproducibility of the clocks after being transported between countries was sufficient to determine geopotential height offsets at the level of 4 cm. Our campaign paves the way for redefining the SI second and has a significant impact on various applications, including tests of general relativity, geodetic sensing for geosciences, precise navigation, and future timing networks.

physics.atom-ph

Analyzing a single-laser repumping scheme for efficient loading of a strontium magneto-optical trap

We demonstrate enhanced loading of strontium atoms into a magneto-optical trap using a repumping scheme from the metastable state via the doubly-excited state $5\mathrm{s}5\mathrm{p}\,^3\mathrm{P}_2 \rightarrow 5\mathrm{p}^2\,^3\mathrm{P}_2$ at $481~\mathrm{nm}$. The number of trapped atoms is increased by an order of magnitude. The frequency and intensity dependence of the atom number enhancement, with respect to the non-repumping case, is well reproduced by a simple rate equation model, which also describes single-laser repumping schemes reported previously. The repumping scheme is limited by a weak additional loss channel into the long-lived $5\mathrm{s}5\mathrm{p}\,^3\mathrm{P}_0$ state. For low repumping intensities, the signature of a halo formed by magnetically trapped atoms in the metastable state is found.

physics.atom-ph

Measurement of the strontium triplet Rydberg series by depletion spectroscopy of ultracold atoms

We report on the atom loss spectroscopy of strontium Rydberg atoms in a magneto-optical trap, using a two-photon excitation scheme through the intermediate state $5\mathrm{s}5\mathrm{p} \, ^3\mathrm{P}_1$. Energies of the $5\mathrm{s}n\mathrm{s} \, ^3\mathrm{S}_1$ and $5\mathrm{s}n\mathrm{d} \, ^3\mathrm{D}_{1,2}$ Rydberg series of $^{88}$Sr in the range $13 \leq n \leq 50$ are determined with an absolute accuracy of 10 MHz, including the perturbed region where the $5\mathrm{s}n\mathrm{d} \, ^3\mathrm{D}_{2}$ series couples to the $5\mathrm{s}n\mathrm{d} \, ^1\mathrm{D}_{2}$ series. This represents an improvement by more than two orders of magnitude compared to previously published data. The quantum defects for each series are determined using the extended Rydberg-Ritz formula in the range where there is no strong perturbation. A value of $1\,377\,012\,721(10) \,\mathrm{MHz}$ for the first ionization limit of $^{88}$Sr is extracted.

physics.atom-ph

Laser frequency stabilization using a commercial wavelength meter

We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan deviation below $10^{-9}$ with a standard deviation of $1$ MHz over 10\,h is achieved. Using this laser for cooling and trapping of strontium atoms, the wavemeter scheme provides excellent stability in single-channel operation. Multi-channel operation with a multimode fiber switch results in fluctuations of the atomic fluorescence correlated to residual frequency excursions of the laser. The wavemeter-based frequency stabilization scheme can be applied to a wide range of atoms and molecules for laser spectroscopy, cooling and trapping.

physics.ins-det

Two-dimensional magneto-optical trap as a source for cold strontium atoms

We report on the realization of a transversely loaded two-dimensional magneto-optical trap serving as a source for cold strontium atoms. We analyze the dependence of the source's properties on various parameters, in particular the intensity of a pushing beam accelerating the atoms out of the source. An atomic flux exceeding $10^9\,\mathrm{atoms/s}$ at a rather moderate oven temperature of $500\,^\circ\mathrm{C}$ is achieved. The longitudinal velocity of the atomic beam can be tuned over several tens of m/s by adjusting the power of the pushing laser beam. The beam divergence is around $60$ mrad, determined by the transverse velocity distribution of the cold atoms. The slow atom source is used to load a three-dimensional magneto-optical trap realizing loading rates up to $10^9\,\mathrm{atoms/s}$ without indication of saturation of the loading rate for increasing oven temperature. The compact setup avoids undesired effects found in alternative sources like, e.g., Zeeman slowers, such as vacuum contamination and black-body radiation due to the hot strontium oven.

physics.atom-ph