SearcharxivSearch

arXiv subjects

Inna Kviatkovsky

Publications and source records attributed to Inna Kviatkovsky.

4 recordsLinked to original sources

High-optical-depth, sub-Doppler-width absorption lines at telecom wavelengths in hot, optically driven rubidium vapor

Doppler broadening presents a major limitation for high-resolution spectroscopy and nonlinear optics in room-temperature atomic vapors. Here, we demonstrate the suppression of Doppler broadening accompanied by pronounced absorption on the upper transition of a three-level ladder system, achieved by dressing the intermediate state with a strong control field. As a concrete realization, we study a hot vapor of $^{87}$Rb where the lower transition is driven by a strong control field resonant with the D2 line at a wavelength of 780 nm, while a weak counter-propagating probe field at the telecom C-band wavelength of 1529 nm ($5P_{(3/2)}\leftrightarrow 4D_{(5/2)}$) interrogates the dressed states. We observe absorption features with a resonant optical depth of approximately 4 and a full width at half maximum of about 17 MHz. Remarkably, this corresponds to an order-of-magnitude reduction relative to the Doppler width, while the optical depth on the upper transition of the ladder scheme exceeds that of the Doppler-broadened lower transition. The measured spectra are in good agreement with theoretical modeling. Combining high optical density with sub-Doppler-width absorption lines typically requires laser-cooled atoms, while our approach profits from the experimental simplicity of a hot-vapor platform.

physics.atom-ph

Mid-IR hyperspectral imaging with undetected photons

Sensing with undetected photons has become a vibrant, application-driven research domain with a special focus on the mid-infrared (mid-IR) wavelength region. Since the mid-IR contains spectral bands with highly specific and strong molecular absorbance signatures, often referred to as fingerprints, a multitude of different samples and their compositions can be detected and quantified spectroscopically. Enhancing this inherently sample alteration-free spectroscopic method with imaging capabilities leads to a powerful technique for environmental monitoring and biomedical applications that enables automated diagnostics while omitting time-consuming and non-reversible labeling steps. To evade the shortcomings of state-of-the-art instruments for mid-IR hyperspectral microscopy related to cost, complexity, power-consumption, and performance, which are associated with technological challenges for mid-IR cameras and low-noise and broadband mid-IR sources, here, we construct a proof-of-concept nonlinear interferometer in a wide-field imaging arrangement combined with high-resolution spectral acquisition by pixelwise quantum Fourier transform infrared spectroscopy. For the broadband range of 2300-3100 cm$^{-1}$, covering the important CH-stretch band, we perform hyperspectral imaging that simultaneously resolves 3500 spatial modes, each with a spectral resolution of 10 cm$^{-1}$ leveraging in total around 10$^5$ spatio-spectrally entangled photon modes. Our image acquisition uses a commercial, megapixel sCMOS camera, while a medium-power and compact c.w. pump laser is the only necessary light source.

physics.optics

Mid-Infrared Microscopy via Position Correlations of Undetected Photons

Quantum imaging with undetected photons (QIUP) has recently emerged as a new powerful imaging tool. Exploiting the spatial entanglement of photon pairs, it allows decoupling of the sensing and detection wavelengths, facilitating imaging in otherwise challenging spectral regions with mature silicon-based detection technology. All existing implementations of QIUP have so far utilised the momentum correlations within the biphoton state. Here, for the first time, we implement and examine theoretically and numerically the complementary scenario - utilising the tight position correlations formed within photon pair at birth. This image plane arrangement facilitates high resolution imaging with comparative experimental ease, and we experimentally show resolutions below 10 $μ$m at a sensing wavelength of 3.7 $μ$m. Moreover, imaging a slice of mouse heart tissue at the mid-IR to reveal morphological features on the cellular level, we further demonstrate the viability of the technique for the life sciences. These results offer new perspectives on the capabilities of QIUP for label-free wide-field microscopy, enabling new real-world applications in biomedical as well as industrial imaging at inaccessible wavelengths.

quant-ph

Microscopy with undetected photons in the mid-infrared

Owing to its capacity for unique (bio)-chemical specificity, microscopy withmid-IR illumination holds tremendous promise for a wide range of biomedical and industrial applications. The primary limitation, however, remains detection; with current mid-IR detection technology often marrying inferior technical capabilities with prohibitive costs. This has lead to approaches that shift detection towavelengths into the visible regime, where vastly superior silicon-based cameratechnology is available. Here, we experimentally show how nonlinear interferometry with entangled light can provide a powerful tool for mid-IR microscopy, while only requiring near-infrared detection with a standard CMOS camera. In this proof-of-principle implementation, we demonstrate intensity imaging overa broad wavelength range covering 3.4-4.3um and demonstrate a spatial resolution of 35um for images containing 650 resolved elements. Moreover, we demonstrate our technique is fit for purpose, acquiring microscopic images of biological tissue samples in the mid-IR. These results open a new perspective for potential relevance of quantum imaging techniques in the life sciences.

physics.optics