SearcharxivSearch

arXiv subjects

Irina Djuraskovic

Publications and source records attributed to Irina Djuraskovic.

2 recordsLinked to original sources

Calibrated Uncertainty for Trustworthy Clinical Gait Analysis Using Probabilistic Multiview Markerless Motion Capture

Video-based human movement analysis holds potential for movement assessment in clinical practice and research. However, the clinical implementation and trust of multi-view markerless motion capture (MMMC) require that, in addition to being accurate, these systems produce reliable confidence intervals to indicate how accurate they are for any individual. Building on our prior work utilizing variational inference to estimate joint angle posterior distributions, this study evaluates the calibration and reliability of a probabilistic MMMC method. We analyzed data from 68 participants across two institutions, validating the model against an instrumented walkway and standard marker-based motion capture. We measured the calibration of the confidence intervals using the Expected Calibration Error (ECE). The model demonstrated reliable calibration, yielding ECE values generally < 0.1 for both step and stride length and bias-corrected gait kinematics. We observed a median step and stride length error of ~16 mm and ~12 mm respectively, with median bias-corrected kinematic errors ranging from 1.5 to 3.8 degrees across lower extremity joints. Consistent with the calibrated ECE, the magnitude of the model's predicted uncertainty correlated strongly with observed error measures. These findings indicate that, as designed, the probabilistic model reconstruction quantifies epistemic uncertainty, allowing it to identify unreliable outputs without the need for concurrent ground-truth instrumentation.

cs.CV

Portable Biomechanics Laboratory: Clinically Accessible Movement Analysis from a Handheld Smartphone

Movement directly reflects neurological and musculoskeletal health, yet objective biomechanical assessment is rarely available in routine care. We introduce Portable Biomechanics Laboratory (PBL), a secure platform for fitting biomechanical models to video collected with a handheld, moving, smartphone. We validate this approach on over 15 hours of data synchronized to ground truth motion capture, finding mean joint-angle errors < 3$\deg$ and pelvis-translation errors of a few centimeters across patients with neurological-injury, lower-limb prosthesis users, pediatric in-patients, and controls. In > 5 hours of prospective deployments to neurosurgery and sports-medicine clinics, PBL was easy to setup, yielded highly reliable gait metrics (ICC > 0.9), and detected clinically relevant differences. For cervical-myelopathy patients, its measurement of gait quality correlated with modified Japanese Orthopedic Association (mJOA) scores and were responsive to clinical intervention. Handheld smartphone video can therefore deliver accurate, scalable, and low-burden biomechanical measurement, enabling greatly increased monitoring of movement impairments. We release the first clinically-validated method for measuring whole-body kinematics from handheld smartphone video at https://IntelligentSensingAndRehabilitation.github.io/MonocularBiomechanics/.

cs.CV