SearcharxivSearch

arXiv subjects

Issei Watanabe

Publications and source records attributed to Issei Watanabe.

4 recordsLinked to original sources

FINER: development of the wideband millimeter-wave receiver system and preparations for first light on the Large Millimeter Telescope

The recent discovery of an excess of luminous galaxies in the early Universe necessitates sensitive and wideband millimeter spectroscopy to understand their rapid growth. To address this, we present the development of the Far-Infrared Nebular Emission Receiver (FINER) for the Large Millimeter Telescope (LMT). The FINER frontend comprises two receivers covering 120-350 GHz (corresponding to ALMA Bands 4+5 and 6+7). The warm optics are designed to enable simultaneous two-band observations. Combined with the 10.24-GHz-wide digital spectrometer array, the system aims to deliver an instantaneous bandwidth approximately five times wider than current ALMA capabilities. We report that the 210-350 GHz receiver has already achieved commissioning-level performance, with sideband rejection further enhanced by the digital sideband separation technique. With installation expected in 2026, we discuss parallel preparations, including integrated testing and commissioning plans for first-look targets.

astro-ph.IM

A Wideband Millimeter-wave Receiver at 210-350 GHz for LMT-FINER

The Far-Infrared Nebular Emission Receiver (FINER) project is developing two wideband dual-polarization sideband-separating receivers covering 120-210 GHz and 210-350 GHz to efficiently identify high-redshift galaxy candidates in the early universe. Based on high-critical-current-density superconductor-insulator-superconductor mixer technology originally developed for the ALMA wideband sensitivity upgrade, the FINER receivers are designed to provide an intermediate-frequency bandwidth of 3-21 GHz per sideband and per polarization, approximately five times wider than the current ALMA specifications. After installation on the Large Millimeter Telescope, these receivers are expected to offer highly efficient spectral-scanning capability among (sub)millimeterwave facilities in the northern-hemisphere. This paper reports the initial laboratory characterization of the 210-350 GHz receiver. The measured single sideband receiver noise temperature is approximately 100 K over most of the radio-frequency band. Digital sideband separation was also demonstrated using a wideband spectrometer array (DRS4), achieving an image rejection ratio of around 20 dB in the initial tests. These results represent an important step toward the realization of a wideband spectral-scanning receiver system for FINER.

astro-ph.IM

Trade-off relations between measurement dependence and hidden information for factorizable hidden variable models

The Bell theorem is explored in terms of a trade-off relation between underlying assumptions within the hidden variable model framework. In this paper, recognizing the incorporation of hidden variables as one of the fundamental assumptions, we propose a measure termed `hidden information' taking account of their distribution. This measure quantifies the number of hidden variables that essentially contribute to the empirical statistics. For factorizable models, hidden variable models that satisfy `locality' without adhering to the measurement independence criterion, we derive novel relaxed Bell-Clauser-Horne-Shimony-Holt (Bell-CHSH) inequalities. These inequalities elucidate trade-off relations between measurement dependence and hidden information in the CHSH scenario. It is also revealed that the relation gives a necessary and sufficient condition for the measures to be realized by a factorizable model.

quant-ph

Waveguide-Type Multiplexer for Multiline Observation of Atmospheric Molecules using Millimeter-Wave Spectroradiometer

In order to better understand the variation mechanism of ozone abundance in the middle atmosphere, the simultaneous monitoring of ozone and other minor molecular species, which are related to ozone depletion, is the most fundamental and critical method. A waveguide-type multiplexer was developed for the expansion of the observation frequency range of a millimeter-wave spectroradiometer, for the simultaneous observation of multiple molecular spectral lines. The proposed multiplexer contains a cascaded four-stage sideband-separating filter circuit. The waveguide circuit was designed based on electromagnetic analysis, and the pass frequency bands of Stages 1-4 were 243-251 GHz, 227-235 GHz, 197-205 GHz, and 181-189 GHz. The insertion and return losses of the multiplexer were measured using vector network analyzers, each observation band was well-defined, and the bandwidths were appropriately specified. Moreover, the receiver noise temperature and the image rejection ratio (IRR) using the superconducting mixer at 4 K were measured. As a result, the increase in receiver noise due to the multiplexer compared with that of only the mixer can be attributed to the transmission loss of the waveguide circuit in the multiplexer. The IRRs were higher than 25 dB at the center of each observation band. This indicates that a high and stable IRR performance can be achieved by the waveguide-type multiplexer for the separation of sideband signals.

astro-ph.IM