SearcharxivSearch

arXiv subjects

Ivan Caicedo

Publications and source records attributed to Ivan Caicedo.

9 recordsLinked to original sources

X-ray Irradiation Studies on the Monopix DMAPS in 150$\,$nm and 180$\,$nm

Monolithic active pixel sensors with depleted substrates present a promising option for pixel detectors in high-radiation environments. High-resistivity silicon substrates and high bias voltage capabilities in commercial CMOS technologies facilitate depletion of the charge sensitive volume. TJ-Monopix2 and LF-Monopix2 are the most recent large-scale chips in their respective development line, aiming for the ATLAS Inner Tracker outer layer requirements. Those include a tolerance to ionizing radiation of up to 100$\,$Mrad. It was evaluated by irradiating both devices with X-rays to the corresponding ionization dose, showing no significant degradation of the performance at 100$\,$Mrad and continuous operability throughout the irradiation campaign.

physics.ins-det

Cross talk of a large-scale depleted monolithic active pixel sensor (DMAPS) in 180 nm CMOS technology

Monolithic pixel detectors combine readout electronics and sensor in a single entity of silicon, which simplifies the production procedure and lowers the material budget compared to conventional hybrid pixel detector concepts. Benefiting from the advances in commercial CMOS processes towards large biasing voltage capabilities and the increasing availability of high-resistivity substrates, depleted monolithic active pixel sensors (DMAPS) are able to cope with the high-rate and high-radiation environments faced in modern high-energy physics experiments. TJ-Monopix2 is the latest iteration of a DMAPS development line designed in 180 nm TowerSemicondutor technology, which features a large scale (2 x 2) cm$^2$ chip divided into (512 x 512) pixels with a pitch of (33 x 33) um$^2$. All in-pixel electronics are separated from its small collection electrode and process modifications are implemented to improve charge collection efficiency especially after irradiation. The latest laboratory measurements and investigations of a threshold variation observed for TJ-Monopix2 in typical operating conditions are presented.

physics.ins-det

Breakdown Performance of Guard Ring Designs for Pixel Detectors in $150~\mathrm{nm}$ CMOS Technology

Silicon pixel sensors manufactured using commercial CMOS processes are promising instruments for high-energy particle physics experiments due to their high yield and proven radiation hardness. As one of the essential factors for the operation of detectors, the breakdown performance of pixel sensors constitutes the upper limit of the operating voltage. Six types of passive CMOS test structures were fabricated on high-resistivity wafers. Each of them features a combination of different inter-pixel designs and sets of floating guard rings, which differ from each other in the geometrical layout, implantation type, and overhang structure. A comparative study based on leakage current measurements in the sensor substrate of unirradiated samples was carried out to identify correlations between guard ring designs and breakdown voltages. TCAD simulations using the design parameters of the test structures were performed to discuss the observations and, together with the measurements, ultimately provide design features targeting higher breakdown voltages.

physics.ins-det

Charge collection and efficiency measurements of the TJ-Monopix2 DMAPS in 180$\,$nm CMOS technology

Monolithic CMOS pixel detectors have emerged as competitive contenders in the field of high-energy particle physics detectors. By utilizing commercial processes they offer high-volume production of such detectors. A series of prototypes has been designed in a 180$\,$nm Tower process with depletion of the sensor material and a column-drain readout architecture. The latest iteration, TJ-Monopix2, features a large 2$\,$cm x 2$\,$cm matrix consisting of 512 x 512 pixels with 33.04$\,$um pitch. A small collection electrode design aims at low power consumption and low noise while the radiation tolerance for high-energy particle detector applications needs extra attention. With a goal to reach radiation tolerance to levels of $10^{15}\,1\,$MeV n$_\text{eq}\,$cm$^{-2}$ of NIEL damage a modification of the standard process has been implemented by adding a low-dosed n-type silicon implant across the pixel in order to allow for homogeneous depletion of the sensor volume. Recent lab measurements and beam tests were conducted for unirradiated modules to study electrical characteristics and hit detection efficiency.

physics.ins-det

DMAPS Monopix developments in large and small electrode designs

LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150 nm LFoundry and 180 nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows a design with large charge collection electrode where readout electronics are placed inside. Generally, this offers a homogeneous electrical field in the sensor and short drift distances. TJ-Monopix1 employs a small charge collection electrode with readout electronics separated from the electrode and an additional n-type implant to achieve full depletion of the sensitive volume. This approach offers a low sensor capacitance and therefore low noise and is typically implemented with small pixel size. Both detectors have been characterized before and after irradiation using lab tests and particle beams.

physics.ins-det

The Monopix chips: Depleted monolithic active pixel sensors with a column-drain read-out architecture for the ATLAS Inner Tracker upgrade

Two different depleted monolithic CMOS active pixel sensor (DMAPS) prototypes with a fully synchronous column-drain read-out architecture were designed and tested: LF-Monopix and TJ-Monopix. These chips are part of a R&D effort towards a suitable implementation of a CMOS DMAPS for the HL-LHC ATLAS Inner Tracker. LF-Monopix was developed using a 150nm CMOS process on a highly resistive substrate (>2 k$Ω\,$cm), while TJ-Monopix was fabricated using a modified 180 nm CMOS process with a 1 k$Ω\,$cm epi-layer for depletion. The chips differ in their front-end design, biasing scheme, pixel pitch, dimensions of the collecting electrode relative to the pixel size (large and small electrode design, respectively) and the placement of read-out electronics within such electrode. Both chips were operational after thinning down to 100 $\mathrmμ$m and additional back-side processing in LF-Monopix for total bulk depletion. The results in this work include measurements of their leakage current, noise, threshold dispersion, response to minimum ionizing particles and efficiency in test beam campaigns. In addition, the outcome from measurements after irradiation with neutrons up to a dose of $1\times10^{15}\,\mathrm{n_{eq} / cm}^{2}$ and its implications for future designs are discussed.

physics.ins-det

Depleted Fully Monolithic Active CMOS Pixel Sensors (DMAPS) in High Resistivity 150~nm Technology for LHC

Depleted monolithic CMOS active pixel sensors (DMAPS) have been developed in order to demonstrate their suitability as pixel detectors in the outer layers of a toroidal LHC apparatus inner tracker (ATLAS ITk) pixel detector in the high-luminosity large hadron collider (HL-LHC). Two prototypes have been fabricated using 150 nm CMOS technology on high resistivity (> 2 k$Ω$ $cm^2$) wafers. The chip size is equivalent to that of the current ATLAS pixel detector readout chip. One of the prototypes is used for detailed characterization of the sensor and the analog readout of the DMAPS. The other is a fully monolithic DMAPS including fast readout digital logic that handles the required hit rate. In order to yield a strong homogeneous electric field within the sensor volume, thinning of the wafer was tested. The prototypes were irradiated with X-ray up to a total ionization dose (TID) of 50 Mrad and with neutrons up to non-ionizing energy loss (NIEL) of $10^{15}$ $n_{eq}/cm^2$. The analog readout circuitry maintained its performance after TID irradiation, and the hit-efficiency at > $10^7$ noise occupancy was as high as 98.9 % after NIEL irradiation.

physics.ins-det

Development of depleted monolithic pixel sensors in 150 nm CMOS technology for the ATLAS Inner Tracker upgrade

This work presents a depleted monolithic active pixel sensor (DMAPS) prototype manufactured in the LFoundry 150 nm CMOS process. The described device, named LF-Monopix, was designed as a proof of concept of a fully monolithic sensor capable of operating in the environment of outer layers of the ATLAS Inner Tracker upgrade for the High Luminosity Large Hadron Collider (HL-LHC). Implementing such a device in the detector module will result in a lower production cost and lower material budget compared to the presently used hybrid designs. In this paper the chip architecture will be described followed by the simulation and measurement results.

physics.ins-det

Precision Luminosity of LHC Proton-Proton Collisions at 13 TeV Using Hit-Counting with TPX Pixel Devices

A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a function of time as a stand-alone system. The data were recorded from 13 TeV proton-proton collisions in 2015. Using two TPX devices, the number of hits created by particles passing the pixel matrices was counted. A van der Meer scan of the LHC beams was analysed using bunch-integrated luminosity averages over the different bunch profiles for an approximate absolute luminosity normalization. It is demonstrated that the TPX network has the capability to measure the reduction of LHC luminosity with precision. Comparative studies were performed among four sensors (two sensors in each TPX device) and the relative short-term precision of the luminosity measurement was determined to be 0.1% for 10 s time intervals. The internal long-term time stability of the measurements was below 0.5% for the data-taking period.

physics.ins-det