Searcharxiv⌕ Search

arXiv subjects

Jérôme Lodewyck

Publications and source records attributed to Jérôme Lodewyck.

15 recordsLinked to original sources

First observation and measurement of the ${}^{198}\text{Hg}$ bosonic transition in an optical lattice clock

We report the first observation of the magnetic-field-induced (5d10 6s2)1S0-(5d10 6s6p)3P0 transition in a bosonic isotope of mercury, 198Hg, realized in an optical lattice clock. We characterize this new isotope, determining key features such as the quadratic Zeeman shift, the probe light shift, and the magic frequency. We also report a first comparison between the 198Hg optical lattice clock and 87Sr. In this comparison, the 198Hg clock has a relative frequency stability of 6x10-16/sqrt(tau/s) and a total relative systematic uncertainty of 6.9x10-16. This comparison yields the first direct determination of the 198Hg/87Sr optical frequency ratio: 198Hg/87Sr = 2.629 315 734 684 118 1, with the same relative uncertainty.

physics.atom-ph↗

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph↗

Guidelines for designs for ultrastable laser with $\mathbf{10^{-17}}$ fractional frequency instability

Lasers with long coherence time and narrow linewidth are an essential tool for quantum sensors and clocks. Ultrastable cavities and laser systems are now commercially available with fractional frequency instabilities in the mid $10^{-16}$ range. This document aims to provide technical guidance for researchers starting in the field of ultrastable lasers and to give an outlook toward the next generation of improved ultrastable lasers. These guidelines have arisen from the scope of the EMPIR project ``Next generation ultrastable lasers'' ( https://www.ptb.de/empir2021/nextlasers ) with contributions from the European project partners.

physics.optics↗

Properties of a definition of the SI second based on several optical transitions

The current definition of the SI second based on the Cs ground state hyperfine transition is expected to be replaced by a new definition based on optical frequency standards in the next decade. Several options are currently under consideration for the new definition, including a definition based on the weighted geometric mean of several transitions. In this paper, we review several properties of this option, and most notably introduce a quantitative method to set the weights of transitions, and a graphical representation of the unit that make the distinction between the definition and the realisation of the unit easier to understand.

physics.atom-ph↗

A definition of the SI second based on several optical transitions

A new definition of the SI second based on optical transitions is expected to be adopted within the next 10 years. Several options for this redefinition are currently under consideration. Among them, a definition based on several transitions would take advantage of the variety of high performance optical frequency standards. In this paper, we review practical aspects such a definition entails, and propose a detailed analysis of its strengths and weaknesses.

physics.atom-ph↗

Search for vector dark matter in microwave cavities with Rydberg atoms

We propose a novel experiment to search for dark matter, based on the application of an electric field inside a microwave cavity and electrometry using Rydberg atoms. We show that this kind of experiment could be extremely useful for detecting specific dark matter candidates, namely massive vector fields coupled to the photon field, more commonly known as dark photons. Such a massive vector field is a good candidate for dark matter. Using realistic experimental parameters we show that such an experiment could improve the current constraint on the coupling constant of the dark photons to Standard Model photons in the 1~$μ$eV to 10~$μ$eV mass range, with the possibility of tuning the maximum sensitivity via the cavity size. The main limiting factors on the sensitivity of the experiment are the amplitude stability of the applied field and the measurement uncertainty of the electric field by the atoms.

physics.atom-ph↗

Improving Short-Term Stability in Optical Lattice Clocks by Quantum Nondemolition Measurements

We propose a multimeasurement estimation protocol for Quantum Nondemolition (QND) measurements in a Rabi clock interferometer. The method is well suited for current state-of-the-art optical lattice clocks with QND measurement capabilities. The protocol exploits the correlations between multiple non-destructive measurements of the initially prepared coherent spin state. A suitable Gaussian estimator for the clock laser detuning is presented, and an analytic expression for the sensitivity of the protocol is derived. We use this analytic expression to optimise the protocol using available experimental parameters, achieving an improvement of $7.9$dB with respect to the standard quantum limit (SQL) in terms of clock stability. We also discuss the measurement back-action effects of our protocol into the atomic state.

quant-ph↗

Universal formalism for data sharing and processing in clock comparison networks

We present a mathematical framework adapted to the comparison of atomic clocks remotely connected by a complex network of optical or microwave links. This framework facilitates the computation of frequency ratios using a generic set of equations that are valid for a wide variety of clock architectures, making the comparison of a large number of clocks practical. This formalism suggests a generic data exchange protocol that can be used in clock comparison collaborations, for which data logging and decision taking are completely local procedures, independently implemented by the participants.

physics.atom-ph↗

On a definition of the SI second with a set of optical clock transitions

The current SI second based on the atomic hyperfine transition in the ground state of 133Cs is expected to be replaced by a new definition based on optical frequency standards, whose estimated uncertainty has now been established two orders of magnitude lower than the accuracy of the best Cs primary standards. However, such a redefinition of the second is hindered by the fact that many atomic species are potential contenders to become the new primary frequency standard. In this paper, we propose to resolve this issue by defining a composite frequency unit based on the weighted geometric mean of the individual frequencies of different atomic transitions. This unit has the property to be realisable with any single clock whose transition composes the unit, provided that at least a few frequency ratios are available, with an accuracy that marginally differs from the nominal clock uncertainty. We show that the unit can be updated as the performances of the contributing transitions evolve, without incurring a drift on the unit itself.

physics.atom-ph↗

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph↗

Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock

Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.

physics.atom-ph↗

Atomic clocks: new prospects in metrology and geodesy

We present the latest developments in the field of atomic clocks and their applications in metrology and fundamental physics. In the light of recent advents in the accuracy of optical clocks, we present an introduction to the relativistic modelization of frequency transfer and a detailed review of chronometric geodesy.

physics.atom-ph↗

Observation and cancellation of the dc Stark shift in strontium optical lattice clocks

We report on the observation of a dc Stark frequency shift at the $10^{-13}$ level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residual dc Stark frequency shift on the clock transition at the $10^{-18}$ level by applying an external electric field. This study shows that the dc Stark shift can play an important role in the accuracy budget of lattice clocks, and should be duly taken into account.

physics.atom-ph↗

Lattice Induced Frequency Shifts in Sr Optical Lattice Clocks at the $10^{-17}$ Level

We present a comprehensive study of the frequency shifts associated with the lattice potential for a Sr lattice clock. By comparing two such clocks with a frequency stability reaching $5\times 10^{-17}$ after a one hour integration time, and varying the lattice depth up to $U_0=900 \, E_r$ with $E_r$ being the recoil energy, we evaluate lattice related shifts with an unprecedented accuracy. We put the first experimental upper bound on the recently predicted frequency shift due to the magnetic dipole (M1) and electric quadrupole (E2) interactions. This upper bound is significantly smaller than the theoretical upper limit. We also give a new upper limit on the effect of hyperpolarizability with an improvement by more than one order of magnitude. Finally, we report the first observation of the vector and tensor shifts in a lattice clock. Combining these measurements, we show that all known lattice related perturbation will not affect the clock accuracy down to the $10^{-17}$ level, even for very deep lattices, up to $U_0=150\,E_r$.

physics.atom-ph↗

Controlling excess noise in fiber optics continuous variables quantum key distribution

We describe a continuous variables coherent states quantum key distribution system working at 1550 nm, and entirely made of standard fiber optics and telecom components, such as integrated-optics modulators, couplers and fast InGaAs photodiodes. The setup is composed of an emitter randomly modulating a coherent state in the complex plane with a doubly Gaussian distribution, and a receiver based on a shot noise limited time-resolved homodyne detector. By using a reverse reconciliation protocol, the device can transfer a raw key rate up to 1 Mb/s, with a proven security against Gaussian or non-Gaussian attacks. The dependence of the secret information rate of the present fiber set-up is studied as a function of the line transmission and excess noise.

quant-ph↗