Searcharxiv⌕ Search

arXiv subjects

J. -C. Salvignol

Publications and source records attributed to J. -C. Salvignol.

5 recordsLinked to original sources

Euclid preparation. Overview of Euclid infrared detector performance from ground tests

The paper describes the objectives, design and findings of the pre-launch ground characterisation campaigns of the Euclid infrared detectors. The pixel properties, including baseline, bad pixels, quantum efficiency, inter pixel capacitance, quantum efficiency, dark current, readout noise, conversion gain, response nonlinearity, and image persistence were measured and characterised for each pixel. We describe in detail the test flow definition that allows us to derive the pixel properties and we present the data acquisition and data quality check software implemented for this purpose. We also outline the measurement protocols of all the pixel properties presented and we provide a comprehensive overview of the performance of the Euclid infrared detectors as derived after tuning the operating parameters of the detectors. The main conclusion of this work is that the performance of the infrared detectors Euclid meets the requirements. Pixels classified as non-functioning accounted for less than 0.2% of all science pixels. IPC coupling is minimal and crosstalk between adjacent pixels is less than 1% between adjacent pixels. 95% of the pixels show a QE greater than 80% across the entire spectral range of the Euclid mission. The conversion gain is approximately 0.52 ADU/e-, with a variation less than 1% between channels of the same detector. The reset noise is approximately equal to 23 ADU after reference pixels correction. The readout noise of a single frame is approximately 13 $e^-$ while the signal estimator noise is measured at 7 $e^-$ in photometric mode and 9 $e^-$ in spectroscopic acquisition mode. The deviation from linear response at signal levels up to 80 k$e^-$ is less than 5% for 95% of the pixels. Median persistence amplitudes are less than 0.3% of the signal, though persistence exhibits significant spatial variation and differences between detectors.

astro-ph.IM↗

Performance of the image persistence model for Euclid infrared detectors

Large-format infrared detectors are at the heart of major ground and space-based astronomical instruments, and the HgCdTe HxRG is the most widely used. The Near Infrared Spectrometer and Photometer (NISP) of the ESA's Euclid mission launched in July 2023 hosts 16 H2RG detectors in the focal plane. Their performance relies heavily on the effect of image persistence, which results in residual images that can remain in the detector for a long time contaminating any subsequent observations. Deriving a precise model of image persistence is challenging due to the sensitivity of this effect to observation history going back hours or even days. Nevertheless, persistence removal is a critical part of image processing because it limits the accuracy of the derived cosmological parameters. We will present the empirical model of image persistence derived from ground characterization data, adapted to the Euclid observation sequence and compared with the data obtained during the in-orbit calibrations of the satellite.

astro-ph.IM↗

Euclid. II. The VIS Instrument

This paper presents the specification, design, and development of the Visible Camera (VIS) on the ESA Euclid mission. VIS is a large optical-band imager with a field of view of 0.54 deg^2 sampled at 0.1" with an array of 609 Megapixels and spatial resolution of 0.18". It will be used to survey approximately 14,000 deg^2 of extragalactic sky to measure the distortion of galaxies in the redshift range z=0.1-1.5 resulting from weak gravitational lensing, one of the two principal cosmology probes of Euclid. With photometric redshifts, the distribution of dark matter can be mapped in three dimensions, and, from how this has changed with look-back time, the nature of dark energy and theories of gravity can be constrained. The entire VIS focal plane will be transmitted to provide the largest images of the Universe from space to date, reaching m_AB>24.5 with S/N >10 in a single broad I_E~(r+i+z) band over a six year survey. The particularly challenging aspects of the instrument are the control and calibration of observational biases, which lead to stringent performance requirements and calibration regimes. With its combination of spatial resolution, calibration knowledge, depth, and area covering most of the extra-Galactic sky, VIS will also provide a legacy data set for many other fields. This paper discusses the rationale behind the VIS concept and describes the instrument design and development before reporting the pre-launch performance derived from ground calibrations and brief results from the in-orbit commissioning. VIS should reach fainter than m_AB=25 with S/N>10 for galaxies of full-width half-maximum of 0.3" in a 1.3" diameter aperture over the Wide Survey, and m_AB>26.4 for a Deep Survey that will cover more than 50 deg^2. The paper also describes how VIS works with the other Euclid components of survey, telescope, and science data processing to extract the cosmological information.

astro-ph.IM↗

Euclid. III. The NISP Instrument

The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated, and its technical potentials and limitations. Links to articles providing more details and technical background are included. NISP's 16 HAWAII-2RG (H2RG) detectors with a plate scale of 0.3" pix^-1 deliver a field-of-view of 0.57deg^2. In photo mode, NISP reaches a limiting magnitude of ~24.5AB mag in three photometric exposures of about 100s exposure time, for point sources and with a signal-to-noise ratio (SNR) of 5. For spectroscopy, NISP's point-source sensitivity is a SNR = 3.5 detection of an emission line with flux ~2x10^-16erg/s/cm^2 integrated over two resolution elements of 13.4A, in 3x560s grism exposures at 1.6 mu (redshifted Ha). Our calibration includes on-ground and in-flight characterisation and monitoring of detector baseline, dark current, non-linearity, and sensitivity, to guarantee a relative photometric accuracy of better than 1.5%, and relative spectrophotometry to better than 0.7%. The wavelength calibration must be better than 5A. NISP is the state-of-the-art instrument in the NIR for all science beyond small areas available from HST and JWST - and an enormous advance due to its combination of field size and high throughput of telescope and instrument. During Euclid's 6-year survey covering 14000 deg^2 of extragalactic sky, NISP will be the backbone for determining distances of more than a billion galaxies. Its NIR data will become a rich reference imaging and spectroscopy data set for the coming decades.

astro-ph.IM↗

VIS: the visible imager for Euclid

Euclid-VIS is the large format visible imager for the ESA Euclid space mission in their Cosmic Vision program, scheduled for launch in 2020. Together with the near infrared imaging within the NISP instrument, it forms the basis of the weak lensing measurements of Euclid. VIS will image in a single r+i+z band from 550-900 nm over a field of view of ~0.5 deg2. By combining 4 exposures with a total of 2260 sec, VIS will reach to deeper than mAB=24.5 (10sigma) for sources with extent ~0.3 arcsec. The image sampling is 0.1 arcsec. VIS will provide deep imaging with a tightly controlled and stable point spread function (PSF) over a wide survey area of 15000 deg2 to measure the cosmic shear from nearly 1.5 billion galaxies to high levels of accuracy, from which the cosmological parameters will be measured. In addition, VIS will also provide a legacy dataset with an unprecedented combination of spatial resolution, depth and area covering most of the extra-Galactic sky. Here we will present the results of the study carried out by the Euclid Consortium during the period up to the Critical Design Review.

astro-ph.IM↗