SearcharxivSearch

arXiv subjects

J. -F. Muraz

Publications and source records attributed to J. -F. Muraz.

15 recordsLinked to original sources

TIARA: a fast gamma-ray detector for range monitoring in Proton Therapy

We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast plastic beam monitor (described in a separate paper). This work focuses on the design and comprehensive characterization of the gamma-ray detection module. It consists of a monolithic PbF$_2$ crystal (2 $\times$ 1.5 $\times$ 1.5 cm$^{3}$) coupled to a 2 $\times$ 2 SiPM matrix from Hamamatsu. A series of beam tests at different clinical facilities (MEDICYC and ProteusOne in France, CNAO in Italy) enabled the determination of the detector time resolution under various conditions, with values ranging from 222 to 283 ps FWHM (Full Width Half Maximum). Monte Carlo simulations including the optical response of PbF$_2$ allowed for the determination of the detection efficiency as a function of particle type and energy. For the final TIARA prototype, which will be composed of 30 modules, an overall detection efficiency of 0.45% is expected. Comparison with experimental data confirmed that the modules are effectively insensitive to neutrons, yielding an excellent signal-to-noise ratio (SNR), with an estimated SNR of 17 for a module placed at 25 cm from the 148 MeV proton beam axis. These features translate into high range accuracy: while the performance varies with beam energy and irradiation conditions, a range accuracy of 3.3 mm at 2$σ$ significance level was achieved at low intensity with 63 MeV protons at MEDICYC, for a small irradiation spot of $\mathbf{\sim}$10$\mathbf{^{7}}$ protons.

physics.ins-det

Search for Light Dark Matter with NEWS-G at the Laboratoire Souterrain de Modane Using a Methane Target

The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to protons. New constraints are presented in the mass range $0.17$ to $1.2\,\mathrm{GeV/c^2}$, with a 90% confidence level cross-section upper limit of $30.9\,\mathrm{pb}$ for a mass of $0.76\,\mathrm{GeV/c^2}$.

hep-ex

The ionization yield in a methane-filled spherical proportional counter

Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this technology to search for low-mass dark matter, having previously performed searches with detectors at the Laboratoire Souterrain de Modane (LSM), including a recent campaign with a 135 cm diameter SPC filled with methane. While in situ calibrations of the detector response were carried out at the LSM, measurements of the mean ionization yield and fluctuations of methane gas in SPCs were performed using a 30 cm diameter detector. The results of multiple measurements taken at different operating voltages are presented. A UV laser system was used to measure the mean gas gain of the SPC, along with $\mathrm{^{37}Ar}$ and aluminum-fluorescence calibration sources. These measurements will inform the energy response model of future operating detectors.

physics.ins-det

Exploring light dark matter with the DarkSPHERE spherical proportional counter electroformed underground at the Boulby Underground Laboratory

We present the conceptual design and the physics potential of DarkSPHERE, a proposed 3 m in diameter spherical proportional counter electroformed underground at the Boulby Underground Laboratory. This effort builds on the R&D performed and experience acquired by the NEWS-G Collaboration. DarkSPHERE is primarily designed to search for nuclear recoils from light dark matter in the 0.05--10 GeV mass range. Electroforming the spherical shell and the implementation of a shield based on pure water ensures a background level below 0.01 dru. These, combined with the proposed helium-isobutane gas mixture, will provide sensitivity to the spin-independent nucleon cross-section of $2\times 10^{-41} (2\times 10^{-43})$ cm$^2$ for a dark matter mass of $0.1 (1)$ GeV. The use of a hydrogen-rich gas mixture with a natural abundance of $^{13}$C provides sensitivity to spin-dependent nucleon cross-sections more than two orders of magnitude below existing constraints for dark matter lighter than 1 GeV. The characteristics of the detector also make it suitable for searches of other dark matter signatures, including scattering of MeV-scale dark matter with electrons, and super-heavy dark matter with masses around the Planck scale that leave extended ionisation tracks in the detector.

hep-ex

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^α~/~(β+ E_K^α)$ with $α=0.70\pm0.08$ and $β= 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$

physics.ins-det

Solar Kaluza-Klein axion search with NEWS-G

Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal from the background, by identifying the separation of the interaction point of the two photons. The NEWS-G collaboration uses large volume Spherical Proportional Counters, gas-filled metallic spheres with a spherical anode in their centre. After observation of a single axionlike event in a 42 day long run with the SEDINE detector, a $90\%$ C.L. upper limit of $g_{aγγ}<8.99\cdot10^{-13}\,GeV^{-1}$ is set on the axion-photon coupling for a KK axion density on Earth of $n_{a}=4.07\cdot10^{13}\,m^{-3}$ and two extra dimensions of size $R = 1\,eV^{-1}$.

hep-ex

Quenching factor measurements of neon nuclei in neon gas

The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.

physics.ins-det

RF pulse amplifier for CVD-diamond particle detectors

This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stamping, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.

physics.ins-det

Copper electroplating for background suppression in the NEWS-G experiment

New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.

physics.ins-det

Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment

Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.

physics.ins-det

First results from the NEWS-G direct dark matter search experiment at the LSM

New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the spin-independent WIMP-nucleon scattering cross-section in the sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times \mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5 $\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to be installed at SNOLAB by summer 2018.

astro-ph.IM

First detection of tracks of radon progeny recoils by MIMAC

The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the Modane underground laboratory. In this paper, we report the first ionization energy and 3D track observations of nuclear recoils produced by the radon progeny. This measurement shows the capability of the MIMAC detector and opens the possibility to explore the low energy recoil directionality signature.

astro-ph.IM

MIMAC low energy electron-recoil discrimination measured with fast neutrons

MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range and $94.67\pm0.19$\% considering a 5~keV lower threshold.

astro-ph.IM

Production of highly-polarized positrons using polarized electrons at MeV energies

The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an initial electron beam momentum of 8.19~MeV/$c$, limited only by the electron beam polarization. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.

physics.acc-ph

Dark Matter directional detection with MIMAC

Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is being developed. In June 2012, a bi-chamber prototype was installed at the LSM (Laboratoire Souterrain de Modane). A preliminary analysis of the first four months data taking allowed, for the first time, the observation of recoils from the $\mathrm{^{222}Rn}$ progeny.

astro-ph.IM