SearcharxivSearch

arXiv subjects

J. -P. Martin

Publications and source records attributed to J. -P. Martin.

15 recordsLinked to original sources

The GRIFFIN Data Acquisition System

Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty better than 0.05% are described. The system has demonstrated the ability to effectively collect signals from High-purity germanium crystals at counting rates up to 50kHz while maintaining good energy resolution, detection efficiency and spectral quality.

physics.ins-det

Final Results of the PICASSO Dark Matter Search Experiment

The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to allow fiducialization and removal of higher activity regions within the detectors. No signal consistent with dark matter was observed. We set limits for spin-dependent interactions on protons of $σ_p^{SD}$~=~1.32~$\times$~10$^{-2}$~pb (90\%~C.L.) at a WIMP mass of 20 GeV/c$^{2}$. In the spin-independent sector we exclude cross sections larger than $σ_p^{SI}$~=~4.86~$\times$~10$^{-5 }$~pb~(90\% C.L.) in the region around 7 GeV/c$^{2}$. The pioneering efforts of the PICASSO experiment have paved the way forward for a next generation detector incorporating much of this technology and experience into larger mass bubble chambers.

hep-ex

Constraints on Low-Mass WIMP Interactions on 19F from PICASSO

Recent results from the PICASSO dark matter search experiment at SNOLAB are reported. These results were obtained using a subset of 10 detectors with a total target mass of 0.72 kg of 19F and an exposure of 114 kgd. The low backgrounds in PICASSO allow recoil energy thresholds as low as 1.7 keV to be obtained which results in an increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below 10 GeV/c^2. No dark matter signal was found. Best exclusion limits in the spin dependent sector were obtained for WIMP masses of 20 GeV/c^2 with a cross section on protons of sigma_p^SD = 0.032 pb (90% C.L.). In the spin independent sector close to the low mass region of 7 GeV/c2 favoured by CoGeNT and DAMA/LIBRA, cross sections larger than sigma_p^SI = 1.41x10^-4 pb (90% C.L.) are excluded.

hep-ex

New Insights into Particle Detection with Superheated Liquids

We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$α$,$γ$). In particular, detectors were spiked with alpha-emitters located inside and outside the droplets. It is shown that the responses are different, depending on whether alpha particles or recoil nuclei create the signals. The energy thresholds for $α$-emitters are compared with test beam measurements using mono-energetic neutrons, as well as with theoretical predictions. Finally a model is presented which describes how the observed intensities of particle induced acoustic signals can be related to the dynamics of bubble growth in superheated liquids. An improved understanding of the bubble dynamics is an important first step in obtaining better discrimination between particle types interacting in detectors of this kind.

physics.ins-det

Dark Matter Spin-Dependent Limits for WIMP Interactions on 19-F by PICASSO

The PICASSO experiment at SNOLAB reports new results for spin-dependent WIMP interactions on $^{19}$F using the superheated droplet technique. A new generation of detectors and new features which enable background discrimination via the rejection of non-particle induced events are described. First results are presented for a subset of two detectors with target masses of $^{19}$F of 65 g and 69 g respectively and a total exposure of 13.75 $\pm$ 0.48 kgd. No dark matter signal was found and for WIMP masses around 24 GeV/c$^2$ new limits have been obtained on the spin-dependent cross section on $^{19}$F of $σ_F$ = 13.9 pb (90% C.L.) which can be converted into cross section limits on protons and neutrons of $σ_p$ = 0.16 pb and $σ_n$ = 2.60 pb respectively (90% C.L). The obtained limits on protons restrict recent interpretations of the DAMA/LIBRA annual modulations in terms of spin-dependent interactions.

hep-ex

Discrimination of nuclear recoils from alpha particles with superheated liquids

The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubbles on alpha tracks, compared to single nucleations created by neutron induced recoils.

physics.ins-det

Micromegas TPC studies at high magnetic fields using the charge dispersion signal

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.

physics.ins-det

Spatial resolution of a GEM readout TPC using the charge dispersion signal

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100 microns with a manageable number of readout pads and channels of electronics, Micro Pattern Gas Detectors (MPGD) are being developed which could use pads comparable in width to the proportional-wire/cathode-pad TPC. We have built a prototype GEM readout TPC with 2 mm x 6 mm pads using the new concept of charge dispersion in MPGDs with a resistive anode. The dependence of transverse resolution on the drift distance has been measured for small angle tracks in cosmic ray tests without a magnetic field for Ar/CO2 (90:10). The GEM-TPC resolution with charge dispersion readout is significantly better than previous measurements carried out with conventional direct charge readout techniques.

physics.ins-det

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.

physics.ins-det

Response of Superheated Droplet Detectors of the PICASSO Dark Matter Search Experiment

We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of superheated liquid Freon droplets dispersed and trapped in a polymerized gel. Phase transitions can be induced by nuclear recoils following particle interactions and, in particular, interactions with Weakly Interacting Massive Particles (WIMPs). These detectors are threshold devices since a minimal energy deposition is necessary to induce a phase transition and their sensitivity to various types of radiation depends strongly on the operating temperature and pressure. The sensitivity to neutrons, alpha particles and gamma rays was determined as a function of these operating parameters and the results are compared with simulations. In particular, we present a complete characterization of the response of detector modules already in use for a dark matter search at the SNO site to detect WIMPs and discuss possible background sources.

physics.ins-det

Improved Spin Dependent Limits from the PICASSO Dark Matter Search Experiment

The PICASSO experiment reports an improved limit for the existence of cold dark matter WIMPs interacting via spin-dependent interactions with nuclei. The experiment is installed in the Sudbury Neutrino Observatory at a depth of 2070 m. With superheated C4F10 droplets as the active material, and an exposure of 1.98+-0.19 kgd, no evidence for a WIMP signal was found. For a WIMP mass of 29 GeV/c2, limits on the spin-dependent cross section on protons of sigma_p = 1.31 pb and on neutrons of sigma_n = 21.5 pb have been obtained at 90% C.L. In both cases, some new parameter space in the region of WIMP masses below 20 GeV/c2 has now been ruled out. The results of these measurements are also presented in terms of limits on the effective WIMP-proton and neutron coupling strengths a_p and a_n.

hep-ex

Resolution studies of cosmic-ray tracks in a TPC with GEM readout

A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the spatial resolution of cosmic-ray tracks in a GEM TPC are presented. We find that the resolution suffers if the readout pads are too wide with respect to the charge distribution at the readout plane due to insufficient charge sharing. For narrow pads of 2 x 6 mm**2 we measure a resolution of 100 micometer at short drift distances in the absence of an axial magnetic field. The dependence of the spatial resolution as a function of drift distance allows the determination of the underlying electron statistics. Our results show that the present technique uses about half the statistical power available from the number of primary electrons. The track angle effect is observed as expected.

physics.ins-det

Position Sensing from Charge Dispersion in Micro-Pattern Gas Detectors with a Resistive Anode

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number of electronics channels for certain potential micro-detector applications such as the Time Projection Chamber. We describe below a new technique to achieve good spatial resolution without increasing the electronics channel count in a modified micro-detector outfitted with a high surface resistivity anode readout structure. The concept and preliminary measurements of spatial resolution from charge dispersion in a modified GEM detector with a resistive anode are described below.

physics.ins-det

Higgs Physics at LEP2

In this report we review the prospects for Higgs physics at LEP2. The theoretical aspects and the phenomenology of Higgs particles are discussed within the Standard Model (SM) and the Minimal Supersymmetric Standard Model (MSSM). The experimental search techniques are described and the discovery limits for Higgs bosons in the LEP2 energy range are summarized. In addition, opportunities of detecting Higgs particles in non-minimal extensions of the SM and the MSSM are investigated.

hep-ph