Searcharxiv⌕ Search

arXiv subjects

J. A. M. Lopes

Publications and source records attributed to J. A. M. Lopes.

119 records · Page 7Linked to original sources

Measurements of photoelectron extraction efficiency from CsI into mixtures of Ne with CH4, CF4, CO2 and N2

Experimental measurements of the extraction efficiency f of the UV-induced photoelectrons emitted from a CsI photocathode into gas mixtures of Ne with CH4, CF4, CO2 and N2 are presented; they are compared with model-simulation results. Backscattering of low- energy photoelectrons emitted into noble gas is significantly reduced by the admixture of molecular gases, with direct impact on the effective quantum efficiency. Data are provided on the dependence of f on the type and concentration of the molecular gas in the mixtures and on the electric field.

physics.ins-det↗

NEXT, a HPGXe TPC for neutrinoless double beta decay searches

We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological signature, the design discussed in this Letter Of Intent promises to be competitive and possibly out-perform existing proposals for next-generation neutrinoless double-beta decay experiments. We discuss the detection principles, design specifications, physics potential and R&D plans to construct a detector with 100 kg fiducial mass in the double-beta decay emitting isotope Xe(136), to be installed in the Canfranc Underground Laboratory.

hep-ex↗

The scintillation and ionization yield of liquid xenon for nuclear recoils

XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.

astro-ph↗

Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment

XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.

astro-ph↗

First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory

The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.

astro-ph↗

Secondary Scintillation Yield in Pure Xenon

The xenon secondary scintillation yield was studied as a function of the electric field in the scintillation region, in a gas proportional scintillation counter operated at room temperature. A large area avalanche photodiode was used for the readout of the VUV secondary scintillation produced in the gas, together with the 5.9 keV x-rays directly absorbed in the photodiode. The latter was used as a reference for the determination of the number of charge carriers produced by the scintillation pulse and, thus, the number of VUV photons impinging the photodiode. A value of 140 photons/kV was obtained for the scintillation amplification parameter. The attained results are in good agreement with those predicted, for room temperature, by Monte Carlo simulation and Boltzmann calculations, as well as with those obtained for saturated xenon vapour, at cryogenic temperatures, and are about a factor of two higher than former results measured at room temperature.

physics.ins-det↗

Characterization of large area avalanche photodiodes in X-ray and VUV-light detection

The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.

physics.ins-det↗

Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state

Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $μp$ atom). In addition, a value of the $μp$ cascade time, $T_\mathrm{cas}^{μp} = (37\pm5)$ ns, was found.

physics.atom-ph↗

3D Position Sensitive XeTPC for Dark Matter Search

The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.

astro-ph↗

Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber

Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded ionization chamber to measure the charge yield. We confirm that using a LAAPD in LXe does not introduce impurities which inhibit the drifting of free electrons.

physics.ins-det↗

Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy

An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.

physics.ins-det↗