SearcharxivSearch

arXiv subjects

J. Alonso

Publications and source records attributed to J. Alonso.

At least 19 recordsLinked to original sources

A fully open-source framework for streaming and cloud-processing of low-field MRI data

Purpose: To present a fully open-source framework for quasi-real-time streaming and cloud-based processing of low-field (LF) MRI data, addressing the growing computational demands of advanced reconstruction and post-processing pipelines in portable and affordable MRI systems. Methods: The proposed framework integrates open-source scanner control software with a network-enabled streaming architecture, allowing for raw data to be transmitted directly from the MRI console to remote compute resources. Cloud-based processing modules support image reconstruction and advanced post-processing, including computationally intensive physics- and learning-based methods, while maintaining compatibility with low-cost on-device control hardware. Results: The system enables continuous acquisition-to-reconstruction workflows in LF-MRI without requiring specialized high-performance console architectures. Selected example applications include deep-learning-based denoising, field-induced distortion correction, and non-Cartesian image reconstruction. Experimental demonstrations show reliable streaming performance. Conclusions: Open-source streaming and cloud-processing provide an effective pathway to overcome the computational limitations of embedded LF-MRI consoles. By decoupling acquisition hardware from intensive reconstruction workloads, the proposed framework supports scalable deployment of advanced algorithms while preserving the affordability and portability that motivate LF-MRI.

physics.comp-ph

MaRGA: a Graphical and Application Interface for MaRCoS

The open-source console MaRCoS, which stands for "Magnetic Resonance Control System", combines hardware, firmware and software elements for integral control of Magnetic Resonance Imaging (MRI) scanners. Previous developments have focused on making the system robust and reliable, rather than on users, who have been somewhat overlooked. This work describes a Graphical User Interface (GUI) designed for intuitive control of MaRCoS, as well as compatibility with clinical environments. The GUI is based on an uncomplicated set of panels and a renewed Application Program Interface (API). Compared to the previous versions, the MaRGA package ("MaRCoS Graphical Application") includes new functionalities such as the possibility to export images to standard DICOM formats, create and manage clinical protocols, or display and process image reconstructions, among other features conceived to simplify the operation of MRI scanners. All prototypes in our facilities are commanded by MaRCoS and operated with the new GUI. Here we report on its performance on an experimental 0.2 T scanner designed for hard-tissue imaging, as well as a 72~mT portable scanner presently installed in the radiology department of a large hospital. The possibility to customize, adapt and streamline processes has substantially improved our workflows and overall experience.

physics.med-ph

Human-vehicle interaction for autonomous vehicles in crosswalk scenarios: Field experiments with pedestrians and passengers

This paper presents the results of real-world testing of human-vehicle interactions with an autonomous vehicle equipped with internal and external Human Machine Interfaces (HMIs) in a crosswalk scenario. The internal and external HMIs were combined with implicit communication techniques using gentle and aggressive braking maneuvers in the crosswalk. Results have been collected in the form of questionnaires and measurable variables such as distance or speed when the pedestrian decides to cross. The questionnaires show that pedestrians feel safer when the external HMI or the gentle braking maneuver is used interchangeably, while the measured variables show that external HMI only helps in combination with the gentle braking maneuver. The questionnaires also show that internal HMI only improves passenger confidence in combination with the aggressive braking maneuver.

cs.HC

Portable MRI for major sporting events -- a case study on the MotoGP World Championship

The goal of this work is to showcase the clinical value that portable MRI can provide in crowded events and major sports competitions. We temporarily installed a low-field and low-cost portable MRI system for extremity imaging in the medical facilities of the Ricardo Tormo Motor Racing Circuit during the four days of the Motorcycle Grand Prix held in Valencia (Spain), which closed the 2022 season of the MotoGP. During this time, we scanned 14 subjects, running a total of 21 protocols for wrist, knee and ankle imaging. Each protocol included a minimum of one T1-weighted 3D-RARE sequence for general anatomical information, and one 3D-STIR sequence to highlight fluid accumulation and inflammation. The circuit medical staff were able to visualize a number of lesions and conditions in the low-field reconstructions, including gonarthrosis, effusion, or Haglund's syndrome, as well as metallic implants and tissue changes due to surgical interventions. Out of eight low-field acquisitions on previously diagnosed lesions, only two (a meniscus tear and a Baker cyst) were not detected by the experts that evaluated our images. The main highlight was that a low-field MRI scan on a subject reporting pain in a wrist revealed a traumatic arthritis which an X-ray radiograph and visual inspection had missed. We have operated in a scenario where high-field MRI is unlikely to play a role but where a low-field system can lead to improved medical attention. In the case reported here, system transport, installation in the circuit facilities and calibration were all uncomplicated. The images presented to the medical staff were mostly unprocessed and there is thus room for improvement. In conclusion, this work supports the claim that low-field MRI can likely provide added value whenever concepts such as accessibility, portability and low-cost outweigh exquisite detail in images.

physics.med-ph

Benchmarking the performance of a low-cost Magnetic Resonance Control System at multiple sites in the open MaRCoS community

Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360 mT in different settings, all of which used the MaRCoS console for acquiring data, and different types of software interfaces (custom-built GUI or PulSeq overlay) to acquire the data. Results: Images are presented from both phantoms and in vivo from healthy volunteers to demonstrate the image quality that can be obtained from the MaRCoS hardware/software interfaced to different low-field magnets. Conclusions: The results presented here show that a number of different sequences commonly used in the clinic can be programmed into an open-source system relatively quickly and easily, and can produce good quality images even at this early stage of development. Both the hardware and software will continue to develop, and it is an aim of this paper to encourage other groups to join this international consortium.

physics.med-ph

Portable magnetic resonance imaging of patients indoors, outdoors and at home

Mobile medical imaging devices are invaluable for clinical diagnostic purposes both in and outside healthcare institutions. Among the various imaging modalities, only a few are readily portable. Magnetic resonance imaging (MRI), the gold standard for numerous healthcare conditions, does not traditionally belong to this group. Recently, low-field MRI start-up companies have demonstrated the first decisive steps towards portability within medical facilities, but these are so far incompatible with more demanding use cases such as in remote and developing regions, sports facilities and events, medical and military camps, or home healthcare. Here we present in vivo images taken with a light, home-made, low-field extremity MRI scanner outside the controlled environment provided by medical facilities. To demonstrate the true portability of the system and benchmark its performance in various relevant scenarios, we have acquired images of a volunteer's knee in: i) an MRI physics laboratory; ii) an office room; iii) outside a campus building, connected to a nearby power outlet; iv) in open air, powered from a small fuel-based generator; and v) at the volunteer's home. All images have been acquired within clinically viable times, and signal-to-noise ratios (SNR) and tissue contrast suffice for 2D and 3D reconstructions with diagnostic value, with comparable overall image quality across all five situations. Furthermore, the volunteer carries a fixation metallic implant screwed to the femur, which leads to strong artifacts in standard clinical systems but appears sharp in our low-field acquisitions. Altogether, this work opens a path towards highly accessible MRI under circumstances previously unrealistic.

physics.med-ph

Slice-selective Zero Echo Time imaging of ultra-short T2 tissues based on spin-locking

Purpose: To expand the capabilities of Zero Echo Time (ZTE) pulse sequences with a slice selection method suitable for the shortest-lived tissues in the body. Methods: We introduce two new sequences that integrate spin-locking pulses into standard ZTE imaging to achieve slice selection: one for moderately short $T_2$ (DiSLoP), the other for ultra-short $T_2$ samples (PreSLoP). These methods exploit the slower signal decay (at $T_{1\rho}\gg T_2$) to retain the magnetization in the slices during the selection process, which is otherwise comparable to or even much longer than $T_2$. Results: We demonstrate control over the slice profiles and positions for 2D imaging. We measure magnetization decay times during spin-locking ($T_{1\rho}$) as a function of pulse amplitude, showing significant lifetime enhancement for amplitudes as low as 10 uT. We show imaging of slice-selected samples with $T_2$ characteristic times in the range of single milliseconds with DiSLoP and PreSLoP, and with the latter for sub-millisecond $T_2$ tissues. As compared to standard 3D ZTE sequences, PreSLoP achieves the same signal-to-noise ratio (SNR) in 2-5 times shorter scan times, and we argue that this is due to the filling scheme of the finite gap at the center of $k$-space unavoidable with ZTE sequences. Finally, we discuss a combination of DiSLoP with a dynamical decoupling sequence to avoid this central gap, leading to further scan time accelerations. Conclusions: The proposed sequences are capable of slice-selected 2D imaging of tissues with $T_2$ as low as 275 us with good SNR within clinically acceptable scan times.

physics.med-ph

Neutrino Physics Opportunities with the IsoDAR Source at Yemilab

IsoDAR seeks to place a high-power-cyclotron and target combination, as an intense source of $\bar{\nu}_e$ at the level of $\sim 10^{23}$/year, close to a kiloton-scale neutrino detector in order to gain sensitivity to very short-baseline neutrino oscillations ($\bar{\nu}_e \rightarrow \bar{\nu}_{e}$) and perform precision tests of the weak interaction, among other physics opportunities. Recently, IsoDAR has received preliminary approval to be paired with the 2.26~kton target volume liquid scintillator detector at the Yemi Underground Laboratory (Yemilab) in Korea, at a 17~m center-to-center baseline, and cavern excavation for IsoDAR is now complete. In this paper, we present the physics capabilities of IsoDAR@Yemilab in terms of sensitivity to oscillations (via inverse beta decay, IBD; $\bar{\nu}_e+p \rightarrow e^+ + n$), including initial-state wavepacket effects, and the weak mixing angle (via elastic scattering off atomic electrons, $\bar{\nu}_e + e^- \rightarrow \bar{\nu}_e + e^-$). We also introduce a study of IsoDAR sensitivity to new particles, such as a light $X$ boson, produced in the target that decays to $\nu_e \bar \nu_e$.

hep-ex

MATISSE, the VLTI mid-infrared imaging spectro-interferometer

Context:Optical interferometry is at a key development stage. ESO's VLTI has established a stable, robust infrastructure for long-baseline interferometry for general astronomical observers. The present second-generation instruments offer a wide wavelength coverage and improved performance. Their sensitivity and measurement accuracy lead to data and images of high reliability. Aims:We have developed MATISSE, the Multi AperTure mid-Infrared SpectroScopic Experiment, to access high resolution imaging in a wide spectral domain and explore topics such: stellar activity and mass loss; planet formation and evolution in the gas and dust disks around young stars; accretion processes around super massive black holes in AGN. Methods:The instrument is a spectro-interferometric imager covering three atmospheric bands (L,M,N) from 2.8 to 13.0 mu, combining four optical beams from the VLTI's telscopes. Its concept, related observing procedure, data reduction and calibration approach are the product of 30 years of instrumental research. The instrument utilizes a multi-axial beam combination that delivers spectrally dispersed fringes. The signal provides the following quantities at several spectral resolutions: photometric flux, coherent fluxes, visibilities, closure phases, wavelength differential visibilities and phases, and aperture-synthesis imaging. Results:We provide an overview of the physical principle of the instrument and its functionalities, the characteristics of the delivered signal, a description of the observing modes and of their performance limits. An ensemble of data and reconstructed images are illustrating the first acquired key observations. Conclusion:The instrument has been in operation at Cerro Paranal, ESO, Chile since 2018, and has been open for science use by the international community since April 2019. The first scientific results are being published now.

astro-ph.IM

Prepolarized MRI of Hard Tissues and Solid-State Matter

Prepolarized Magnetic Resonance Imaging (PMRI) is a long-established technique conceived to counteract the loss in signal-to-noise ratio (SNR) inherent to low-field MRI systems. When it comes to hard biological tissues and solid-state matter, PMRI is severely restricted by their ultra-short characteristic relaxation times. Here we demonstrate that efficient hard tissue prepolarization is within reach with a special-purpose 0.26 T scanner designed for dental MRI and equipped with suitable high-power electronics. We have characterized the performance of a 0.5 T prepolarizer module which can be switched on and off in just 200 us. To that end, we have used resin, dental and bone samples, all with T1 times in the order of 20 ms at our field strength. The measured SNR enhancement is in good agreement with a simple theoretical model, and small deviations in extreme regimes can be attributed to mechanical vibrations due to the magnetic interaction between the prepolarization and main magnets. Finally, we argue that these results can be applied to clinical dental imaging, opening the door to replacing hazardous X-ray systems with low-field PMRI scanners.

physics.med-ph

Mid-infrared circumstellar emission of the long-period Cepheid l Carinae resolved with VLTI/MATISSE

The nature of circumstellar envelopes (CSE) around Cepheids is still a matter of debate. The physical origin of their infrared (IR) excess could be either a shell of ionized gas, or a dust envelope, or both. This study aims at constraining the geometry and the IR excess of the environment of the long-period Cepheid $\ell$ Car (P=35.5 days) at mid-IR wavelengths to understand its physical nature. We first use photometric observations in various bands and Spitzer Space Telescope spectroscopy to constrain the IR excess of $\ell$ Car. Then, we analyze the VLTI/MATISSE measurements at a specific phase of observation, in order to determine the flux contribution, the size and shape of the environment of the star in the L band. We finally test the hypothesis of a shell of ionized gas in order to model the IR excess. We report the first detection in the L band of a centro-symmetric extended emission around l Car, of about 1.7$R_\star$ in FWHM, producing an excess of about 7.0\% in this band. In the N band, there is no clear evidence for dust emission from VLTI/MATISSE correlated flux and Spitzer data. On the other side, the modeled shell of ionized gas implies a more compact CSE ($1.13\pm0.02\,R_\star$) and fainter (IR excess of 1\% in the L band). We provide new evidences for a compact CSE of $\ell$ Car and we demonstrate the capabilities of VLTI/MATISSE for determining common properties of CSEs. While the compact CSE of $\ell$ Car is probably of gaseous nature, the tested model of a shell of ionized gas is not able to simultaneously reproduce the IR excess and the interferometric observations. Further Galactic Cepheids observations with VLTI/MATISSE are necessary for determining the properties of CSEs, which may also depend on both the pulsation period and the evolutionary state of the stars.

astro-ph.SR

A Fast 0.5T Prepolarizer Module for Preclinical Magnetic Resonance Imaging

We present a magnet and high power electronics for Prepolarized Magnetic Resonance Imaging (PMRI) in a home-made, special-purpose preclinical system designed for simultaneous visualization of hard and soft biological tissues. PMRI boosts the signal-to-noise ratio (SNR) by means of a long and strong magnetic pulse which must be rapidly switched off prior to the imaging pulse sequence, in timescales shorter than the spin relaxation (or T1) time of the sample. We have operated the prepolarizer at up to 0.5 T and demonstrated enhanced magnetization, image SNR and tissue contrast with PMRI of tap water, an ex vivo mouse brain and food samples. These have T1 times ranging from hundreds of milli-seconds to single seconds, while the preliminary high-power electronics setup employed in this work can switch off the prepolarization field in tens of milli-seconds. In order to make this system suitable for solid-state matter and hard tissues, which feature T1 times as short as 10 ms, we are developing new electronics which can cut switching times to ~300 us. This does not require changes in the prepolarizer module, opening the door to the first experimental demonstration of PMRI on hard biological tissues.

physics.ins-det

Peripheral Nerve Stimulation limits with fast narrow and broad-band pulses

Peripheral Nerve Stimulation (PNS) constrains the clinical performance of Magnetic Resonance and Particle Imaging (MRI and MPI) systems. Extensive magneto-stimulation studies have been carried out recently in the field of MPI, where typical operation frequencies range from single to tens of kilo-hertz. PNS literature is scarce for MRI in this regime, where the resonant character of MPI coils prevents studies of broad-band excitation pulses. We have constructed an apparatus for PNS threshold determination on a subject's limb, capable of narrow and broad-band magnetic excitation with pulse characteristic times down to 40 us. From a first set of measurements on 51 volunteers, we observe that PNS limits coincide for sinusoidal (biphasic narrow-band) and triangular (biphasic broad-band) excitations, and are slightly lower for trapezoidal (monophasic broad-band) pulses. We have also measured statistically significant correlations of PNS sensitivity with arm size and body weight, and no correlation with height or gender. As opposed to resonant systems, our setup allows the execution of arbitrarily short pulse trains. We have confirmed thresholds increase significantly as trains transition from tens to a few pulses also in these fast timescales. By changing the polarity of the coils in our setup, we also looked at the influence of the spatial distribution of magnetic field strength on PNS effects. We find that thresholds are higher in an approximately linearly inhomogeneous field (relevant to MRI) than in a rather homogeneous distribution (as in MPI). Finally, given the large intersubject variability of PNS sensitivity, we propose employing a versatile low-cost system (such as presented here) for fast offline determination of a subject's limits prior to medical scanning, and then using this information to boost clinical imaging while preserving the patient's safety.

physics.med-ph

Model-driven reconstruction with phase-constrained highly-oversampled MRI

The Nyquist-Shannon theorem states that the information accessible by discrete Fourier protocols saturates when the sampling rate reaches twice the bandwidth of the detected continuous time signal. This maximum rate (the NS-limit) plays a prominent role in Magnetic Resonance Imaging (MRI). Nevertheless, reconstruction methods other than Fourier analysis can extract useful information from data oversampled with respect to the NS-limit, given that relevant prior knowledge is available. Here we present PhasE-Constrained OverSampled MRI (PECOS), a method that exploits data oversampling in combination with prior knowledge of the physical interactions between electromagnetic fields and spins in MRI systems. In PECOS, highly oversampled-in-time k-space data are fed into a phase-constrained variant of Kaczmarz's algebraic reconstruction algorithm, where prior knowledge of the expected spin contributions to the signal is codified into an encoding matrix. PECOS can be used for scan acceleration in relevant scenarios by oversampling along frequency-encoded directions, which is innocuous in MRI systems under reasonable conditions. We find situations in which the reconstruction quality can be higher than with NS-limited acquisitions and traditional Fourier reconstruction. Besides, we compare the performance of a variety of encoding pulse sequences as well as image reconstruction protocols, and find that accelerated spiral trajectories in k-space combined with algebraic reconstruction techniques are particularly advantageous. The proposed sampling and reconstruction method is able to improve image quality for fully-sampled k-space trajectories, while allowing accelerated or undersampled acquisitions without regularization or signal extrapolation to unmeasured regions.

physics.med-ph

Generic Rotation Sets in Hyperbolic Surfaces

We show that for generic homeomorphisms homotopic to the identity in a closed and oriented surface of genus $g>1$, the rotation set is given by a union of at most $2^{5g-3}$ convex sets. Examples showing the sharpness for this asymptotic order are provided.

math.DS

Simultaneous imaging of hard and soft biological tissues in a low-field dental MRI scanner

Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head and part of a cow femur, all obtained at a field strength of only 260 mT. These images are the first featuring soft and hard tissues simultaneously at sub-Tesla fields, and they have been acquired in a home-made, special-purpose, pre-medical MRI scanner designed with the goal of demonstrating dental imaging at low field settings. We encode spatial information with two variations of zero-echo time (ZTE) pulse sequences: Pointwise-Encoding Time reduction with Radial Acquisition (PETRA) and a new sequence we have called Double Radial Non-Stop Spin Echo (DRaNSSE), which we find to perform better than the former. For image reconstruction we employ Algebraic Reconstruction Techniques (ART) as well as standard Fourier methods. A noise analysis of the resulting images shows that ART reconstructions exhibit a higher signal to noise ratio with a more homogeneous noise distribution.

physics.med-ph

On the geometry of positive cones in finitely generated groups

We study the geometry of positive cones of left-invariant total orders (left-order, for short) in finitely generated groups. We introduce the \textit{Hucha property} and the \texit{Prieto property} for left-orderable groups. The first one means that in any left-order the corresponding positive cone is not coarsely connected, and the second one that in any left-order the corresponding positive cone is coarsely connected. We show that all left-orderable free products have the Hucha property, and that the Hucha property is stable under certain free products with amalgamatation over Prieto subgroups. As an application we show that non-abelian limit groups in the sense of Z. Sela (e.g. free groups, fundamental group of hyperbolic surfaces, doubles of free groups and others) and non-abelian finitely generated subgroups of free $\mathbb{Q}$-groups in the sense of G. Baumslag have the Hucha property. In particular, this implies that these groups have empty BNS-invariant $\Sigma^1$ and that they don't have finitely generated positive cones.

math.GR

Energy consumption for ion transport in a segmented Paul trap

There is recent interest in determining energy costs of shortcuts to adiabaticity (STA), but different definitions of "cost" have been used. We demonstrate the importance of taking into account the Control System (CS) for a fair assessment of energy flows and consumptions. We model the energy consumption and power to transport an ion by a STA protocol in a multisegmented Paul trap. The ion is driven by an externally controlled, moving harmonic oscillator. Even if no net ion- energy is gained at destination, setting the time-dependent control parameters is a macroscopic operation that costs energy and results in energy dissipation for the short time scales implied by the intrinsically fast STA processes. The potential minimum is displaced by modulating the voltages on control (dc) electrodes. A secondary effect of the modulation, usually ignored as it does not affect the ion dynamics, is the time- dependent energy shift of the potential minimum. The non trivial part of the energy consumption is due to the electromotive forces to set the electrode voltages through the low-pass filters required to preserve the electronic noise from decohering the ion's motion. The results for the macroscopic CS (the Paul trap) are compared to the microscopic power and energy of the ion alone. Similarities are found -and may be used quantitatively to minimize costs- only when the CS-dependent energy shift of the harmonic oscillator is included in the ion energy.

quant-ph