SearcharxivSearch

arXiv subjects

J. Alozy

Publications and source records attributed to J. Alozy.

10 recordsLinked to original sources

A flexible DAQ system for the Timepix4 ASIC in the 4DPHOTON project

This paper presents the design and implementation of a flexible data acquisition system13 developed for the Timepix4 ASIC within the 4DPHOTON project. The system is based on a modular14 FPGA-centric architecture combining high-speed serial readout, Ethernet-based data transport,15 and deterministic multi-board synchronization. The hardware platform includes a scalable stack16 composed of commercial FPGA carrier boards, FMC-based interface electronics, detector-specific17 chipboards, and a dedicated Trigger Logic Unit for synchronized operation.18 The firmware architecture separates control and data paths, enabling independent configuration19 and high-throughput acquisition through UDP over 10 GbE links. The design supports zero-back-20 pressure operation toward the ASIC and allows adaptation of the readout bandwidth to different21 experimental conditions. Synchronization between multiple DAQ systems is achieved through22 a common clock and trigger distribution network, experimentally demonstrated with sub-100 ps23 precision.24 The system has been developed to support detector characterization, laboratory measurements,25 and beam-test campaigns for the 4DPHOTON detector concept. Hardware organization, firmware26 architecture, synchronization strategy, and performance measurements are presented.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3$\times$3 mm$^2$ silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 $\pm$ 1) ps FWHM. We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8$\times$2.8$\times$20 mm$^3$ we obtained a coincidence time resolution (CTR) of (130 $\pm$ 1) ps FWHM. With LGSO crystals of 2$\times$2$\times$3 mm$^3$, a CTR of (85 $\pm$ 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.

physics.ins-det

Embedding the Timepix4 in Micro-Pattern Gaseous Detectors

The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its Through Silicon Vias. The latter enables to connect to the Timepix4 from the back side. Thus, it can be tiled on four sides, allowing it to cover large areas without loss of active area. Here, the first results of reading out MPGDs with the Timepix4 are presented. Measurements with a Gas Electron Multiplier (GEM) detector show that event selection based on geometrical parameters of the interaction is possible, X-ray imaging studies can be performed, as well as energy and time-resolved measurements. In parallel, the embedding of a Timepix4 into a micro-resistive Well (uRWell) amplification structure is explored. The first mechanical tests have been successful. The status of the electrical functionality is presented, as well as simulation studies on the signal induction in such a device.

physics.ins-det

Towards MPGDs with embedded pixel ASICs

Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies ($\lessapprox$ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC - specifically the Timepix4 - into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the 'Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.

physics.ins-det

Detector Technologies for CLIC

The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.

physics.ins-det

Identification of particles with Lorentz factor up to $10^{4}$ with Transition Radiation Detectors based on micro-strip silicon detectors

This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to the radiating particles. A detector setup has been built and tested with particles in a wide range of Lorentz factors (from about $10^3$ to about $4 \times 10^4$ crossing different types of radiators. The measured double-differential (in energy and angle) spectra of the TR photons are in a reasonably good agreement with TR simulation predictions.

physics.ins-det

Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.

physics.ins-det

Infrastructure for Detector Research and Development towards the International Linear Collider

The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.

physics.ins-det