Searcharxiv⌕ Search

arXiv subjects

J. B. Hertzberg

Publications and source records attributed to J. B. Hertzberg.

5 recordsLinked to original sources

Effects of surface treatments on flux tunable transmon qubits

One of the main limitations in state-of-the art solid-state quantum processors are qubit decoherence and relaxation due to noise in their local environment. For the field to advance towards full fault-tolerant quantum computing, a better understanding of the underlying microscopic noise sources is therefore needed. Adsorbates on surfaces, impurities at interfaces and material defects have been identified as sources of noise and dissipation in solid-state quantum devices. Here, we use an ultra-high vacuum package to study the impact of vacuum loading, UV-light exposure and ion irradiation treatments on coherence and slow parameter fluctuations of flux tunable superconducting transmon qubits. We analyse the effects of each of these surface treatments by comparing averages over many individual qubits and measurements before and after treatment. The treatments studied do not significantly impact the relaxation rate $Γ_1$ and the echo dephasing rate $Γ_2^\textrm{e}$, except for Ne ion bombardment which reduces $Γ_1$. In contrast, flux noise parameters are improved by removing magnetic adsorbates from the chip surfaces with UV-light and NH$_3$ treatments. Additionally, we demonstrate that SF$_6$ ion bombardment can be used to adjust qubit frequencies in-situ and post fabrication without affecting qubit coherence at the sweet spot.

quant-ph↗

Preparation and Detection of a Mechanical Resonator Near the Ground State of Motion

We have cooled the motion of a radio-frequency nanomechanical resonator by parametric coupling to a driven microwave frequency superconducting resonator. Starting from a thermal occupation of 480 quanta, we have observed occupation factors as low as 3.8$\pm$1.2 and expect the mechanical resonator to be found with probability 0.21 in the quantum ground state of motion. Cooling is limited by random excitation of the microwave resonator and heating of the dissipative mechanical bath.

quant-ph↗

Back-action Evading Measurements of Nanomechanical Motion

When performing continuous measurements of position with sensitivity approaching quantum mechanical limits, one must confront the fundamental effects of detector back-action. Back-action forces are responsible for the ultimate limit on continuous position detection, can also be harnessed to cool the observed structure, and are expected to generate quantum entanglement. Back-action can also be evaded, allowing measurements with sensitivities that exceed the standard quantum limit, and potentially allowing for the generation of quantum squeezed states. We realize a device based on the parametric coupling between an ultra-low dissipation nanomechanical resonator and a microwave resonator. Here we demonstrate back-action evading (BAE) detection of a single quadrature of motion with sensitivity 4 times the quantum zero-point motion, back-action cooling of the mechanical resonator to n = 12 quanta, and a parametric mechanical pre-amplification effect which is harnessed to achieve position resolution a factor 1.3 times quantum zero-point motion.

cond-mat.mes-hall↗

Self-cooling of a micro-mirror by radiation pressure

We demonstrate passive feedback cooling of a mechanical resonator based on radiation pressure forces and assisted by photothermal forces in a high-finesse optical cavity. The resonator is a free-standing high-reflectance micro-mirror (of mass m=400ng and mechanical quality factor Q=10^4) that is used as back-mirror in a detuned Fabry-Perot cavity of optical finesse F=500. We observe an increased damping in the dynamics of the mechanical oscillator by a factor of 30 and a corresponding cooling of the oscillator modes below 10 K starting from room temperature. This effect is an important ingredient for recently proposed schemes to prepare quantum entanglement of macroscopic mechanical oscillators.

quant-ph↗

Measurement of the Relativistic Potential Difference Across a Rotating Dielectric Cylinder

According to the Special Theory of Relativity, a rotating magnetic dielectric cylinder in an axial magnetic field should exhibit a contribution to the radial electric potential that is associated with the motion of the material's magnetic dipoles. In 1913 Wilson and Wilson reported a measurement of the potential difference across a magnetic dielectric constructed from wax and steel balls. Their measurement has long been regarded as a verification of this prediction. In 1995 Pelligrini and Swift questioned the theoretical basis of experiment. In particular, they pointed out that it is not obvious that a rotating medium may be treated as if each point in the medium is locally inertial. They calculated the effect in the rotating frame and predicted a potential different from both Wilson's theory and experiment. Subsequent analysis of the experiment suggests that Wilson's experiment does not distinguish between the two predictions due to the fact that their composite steel-wax cylinder is conductive in the regions of magnetization. We report measurements of the radial voltage difference across various rotating dielectric cylinders, including a homogeneous magnetic material (YIG), to unambiguously test the competing calculations. Our results are compatible with the traditional treatment of the effect using a co-moving locally inertial reference frame, and are incompatible with the predictions based on the model of Pelligrini and Swift.

gr-qc↗