SearcharxivSearch

arXiv subjects

J. Balibrea

Publications and source records attributed to J. Balibrea.

8 recordsLinked to original sources

The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements

A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.

physics.ins-det

High accuracy, high resolution 235U(n,f) cross section from n_TOF (CERN) in the thermal to 10 keV energy range

The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between thermal and 10 keV neutron energy. A resonance analysis has been performed up to 200 eV, with the code SAMMY. The resulting fission kernels are compared with the ones extracted on the basis of the resonance parameters of the most recent major evaluated data libraries. A comparison of the n_TOF data with the evaluated cross sections is also performed from thermal to 10 keV neutron energy for the energy-averaged cross section in energy groups of suitably chosen width. A good agreement is found in average between the new results and the latest evaluated data files ENDF-B/VIII and JEFF-3.3, as well as with respect to the IAEA reference files. However, some discrepancies are still present in some specific energy regions. The new dataset here presented, characterized by unprecedented resolution and accuracy, can help improving the evaluations in the Resolved Resonance Region and up to 10 keV, and reduce the uncertainties that affect this region.

nucl-ex

First i-TED demonstrator: a Compton imager with Dynamic Electronic Collimation

i-TED consists of both a total energy detector and a Compton camera primarily intended for the measurement of neutron capture cross sections by means of the simultaneous combination of neutron time-of-flight (TOF) and $γ$-ray imaging techniques. TOF allows one to obtain a neutron-energy differential capture yield, whereas the imaging capability is intended for the discrimination of radiative background sources, that have a spatial origin different from that of the capture sample under investigation. A distinctive feature of i-TED is the embedded Dynamic Electronic Collimation (DEC) concept, which allows for a trade-off between efficiency and image resolution. Here we report on some general design considerations and first performance characterization measurements made with an i-TED demonstrator in order to explore its $γ$-ray detection and imaging capabilities.

physics.ins-det

Study of multi-neutron emission in the $β$-decay of $^{11}$Li

The kinematics of two-neutron emission following the $β$-decay of $^{11}$Li was investigated for the first time by detecting the two neutrons in coincidence and by measuring their angle and energy. An array of liquid-scintillator neutron detectors was used to reject cosmic-ray and $γ$-ray backgrounds by pulse-shape discrimination. Cross-talk events in which two detectors are fired by a single neutron were rejected using a filter tested on the $β$-1n emitter $^9$Li. A large cross-talk rejection rate is obtained ($> 95 \%$) over most of the energy range of interest. Application to $^{11}$Li data leads to a significant number of events interpreted as $β$-2n decay. A discrete neutron line at $\approx$ 2 MeV indicates sequential two-neutron emission, possibly from the unbound state at 10.6 MeV excitation energy in $^{11}$Be.

nucl-ex

Measurement of the 235U(n,f) cross section relative to the 6Li(n,t) and 10B(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF

The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the reaction yields under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10÷30 keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the evaluated cross section in the 9÷18 keV neutron energy range is indeed overestimated, both in the recent updates of ENDF/B-VIII.0 and of the IAEA reference data. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The new, high accuracy results here reported may lead to a reduction of the uncertainty in the 1÷100 keV neutron energy region. Finally, the present data provide additional confidence on the recently re-evaluated cross section integral between 7.8 and 11 eV.

nucl-ex

Cross section measurements of $^{155,157}$Gd(n,$γ$) induced by thermal and epithermal neutrons

Neutron capture measurements on $^{155}$Gd and $^{157}$Gd were performed using the time-of-flight technique at the n\_TOF facility at CERN. Four samples in form of self-sustaining metallic discs isotopically enriched in $^{155}$Gd and $^{157}$Gd were used. The measurements were carried out at the experimental area (EAR1) at 185 m from the neutron source, with an array of 4 C$_6$D$_6$ liquid scintillation detectors. The capture cross sections of $^{155}$Gd and $^{157}$Gd at neutron kinetic energy of 0.0253 eV have been estimated to be 62.2(2.2) kb and 239.8(9.3) kb, respectively, thus up to 6\% different relative to the ones reported in the nuclear data libraries. A resonance shape analysis has been performed in the resolved resonance region up to 180 eV and 300 eV, respectively, in average resonance parameters have been found in good agreement with evaluations. Above these energies the observed resonance-like structures in the cross section have been tentatively characterised in terms of resonance energy and area up to 1 keV.

nucl-ex

Experimental setup and procedure for the measurement of the 7Be(n,p)7Li reaction at n_TOF

Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron indiced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-lived radioactive isotopes. After the successful measurement of the 7Be(n,α)α cross section, the 7Be(n,p)7Li reaction was studied in order to provide still missing cross section data of relevance for Big Bang Nucleosynthesis (BBN), in an attempt to find a solution to the cosmological Lithium abundance problem. This paper describes the experimental setup employed in such a measurement and its characterization.

physics.ins-det

Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN

Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The $^{243}$Am(n,$γ$) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature has been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the $^{243}$Am(n,$γ$) cross section uncertainty and suggest that this cross section is underestimated up to 25% in the neutron energy range between 50 eV and a few keV in the present evaluated data libraries.

nucl-ex