SearcharxivSearch

arXiv subjects

J. Battat

Publications and source records attributed to J. Battat.

10 recordsLinked to original sources

Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora

The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.

hep-ex

Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network

Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.

physics.ins-det

Background Rejection in the DMTPC Dark Matter Search Using Charge Signals

The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that the addition of the charge readout analysis to the CCD allows us too obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor of $5.6\times10^{-6}$ for recoils with energies between 40 and 200 keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals and light in the CCD reduces CCD-specific backgrounds by more than two orders of magnitude.

astro-ph.IM

A Background-Free Direction-Sensitive Neutron Detector2 A Background-Free Direction-Sensitive Neutron Detector

We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detectors are limited by cosmic ray neutron backgrounds. All applications (neutron scattering and radiography, measurements of solar and cosmic ray neutron flux, measurements of neutron interaction cross sections, monitoring of neutrons at nuclear facilities, oil exploration, and searches for fissile weapons of mass destruction) will benefit from the improved neutron detection sensitivity and improved measurements of neutron properties made possible by this detector. The detector is free of backgrounds from x-rays, gamma rays, beta particles, relativistic singely charged particles and cosmic ray neutrons. It is sensitive to thermal neutrons, fission neutrons, and high energy neutrons, with detection features distinctive for each energy range. It is capable of determining the location of a source of fission neutrons based on characteristics of elastic scattering of neutrons by helium nuclei. The detector we have constructed could identify one gram of reactor grade plutonium, one meter away, with less than one minute of observation time.

physics.ins-det

Transport properties of electrons in CF4

Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the diffusion coefficent, and the attentuation coefficient of electron propagation in CF4 gas using a 10-liter dark matter detector prototype of the DMTPC project.

physics.ins-det

The DMTPC project

The DMTPC detector is a low-pressure CF4 TPC with optical readout for directional detection of Dark Matter. The combination of the energy and directional tracking information allows for an efficient suppression of all backgrounds. The choice of gas (CF4) makes this detector particularly sensitive to spin-dependent interactions.

astro-ph.IM

The DMTPC detector

Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for directional direct detection of WIMPs. By using CF4 gas as the active material, the detector also has excellent sensitivity to spin-dependent interactions of Dark Matter on protons.

astro-ph

DMTPC: a new apparatus for directional detection of Dark Matter

Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for directional direct detection of WIMPs. By using CF4 gas as the active material, the detector also has excellent sensitivity to spin-dependent interactions of Dark Matter on protons.

astro-ph

A map of OMC-1 in CO 9-8

The distribution of 12C16O J=9-8 (1.037 THz) emission has been mapped in OMC-1 at 35 points with 84" resolution. This is the first map of this source in this transition and only the second velocity-resolved ground-based observation of a line in the terahertz frequency band. There is emission present at all points in the map, a region roughly 4' by 6' in size, with peak antenna temperature dropping only near the edges. Away from the Orion KL outflow, the velocity structure suggests that most of the emission comes from the OMC-1 photon-dominated region, with a typical linewidthof 3-6 km/s. Large velocity gradient modeling of the emission in J=9-8 and six lower transitions suggests that the lines originate in regions with temperatures around 120 K and densities of at least 10^(3.5) cm^(-3) near theta^(1) C Ori and at the Orion Bar, and from 70 K gas at around 10^(4) cm^(-3) southeast and west of the bar. These observations are among the first made with the 0.8 m Smithsonian Astrophysical Observatory Receiver Lab Telescope, a new instrument designed to observe at frequencies above 1 THz from an extremely high and dry site in northern Chile.

astro-ph

Mapping the Outflow from G5.89-0.39 in SiO(5-4)

We have mapped the ultracompact HII region, G5.89-0.39, and its molecular surroundings with the Submillimeter Array at 2".8 x 1".8 angular resolution in 1.3 mm continuum, SiO(5-4), and eight other molecular lines. We have resolved for the first time the highly energetic molecular outflow in this region. At this resolution, the outflow is definitely bipolar and appears to originate in a 1.3 mm continuum source. The continuum source peaks in the center of the HII region. The axis of the outflow lines up with a recently discovered O5V star.

astro-ph