SearcharxivSearch

arXiv subjects

J. Brooks

Publications and source records attributed to J. Brooks.

13 recordsLinked to original sources

Virgo Detector Characterization and Data Quality: results from the O3 run

The Advanced Virgo detector has contributed with its data to the rapid growth of the number of detected gravitational-wave (GW) signals in the past few years, alongside the two Advanced LIGO instruments. First during the last month of the Observation Run 2 (O2) in August 2017 (with, most notably, the compact binary mergers GW170814 and GW170817), and then during the full Observation Run 3 (O3): an 11-months data taking period, between April 2019 and March 2020, that led to the addition of about 80 events to the catalog of transient GW sources maintained by LIGO, Virgo and now KAGRA. These discoveries and the manifold exploitation of the detected waveforms require an accurate characterization of the quality of the data, such as continuous study and monitoring of the detector noise sources. These activities, collectively named {\em detector characterization and data quality} or {\em DetChar}, span the whole workflow of the Virgo data, from the instrument front-end hardware to the final analyses. They are described in details in the following article, with a focus on the results achieved by the Virgo DetChar group during the O3 run. Concurrently, a companion article describes the tools that have been used by the Virgo DetChar group to perform this work.

gr-qc

Virgo Detector Characterization and Data Quality: tools

Detector characterization and data quality studies -- collectively referred to as {\em DetChar} activities in this article -- are paramount to the scientific exploitation of the joint dataset collected by the LIGO-Virgo-KAGRA global network of ground-based gravitational-wave (GW) detectors. They take place during each phase of the operation of the instruments (upgrade, tuning and optimization, data taking), are required at all steps of the dataflow (from data acquisition to the final list of GW events) and operate at various latencies (from near real-time to vet the public alerts to offline analyses). This work requires a wide set of tools which have been developed over the years to fulfill the requirements of the various DetChar studies: data access and bookkeeping; global monitoring of the instruments and of the different steps of the data processing; studies of the global properties of the noise at the detector outputs; identification and follow-up of noise peculiar features (whether they be transient or continuously present in the data); quick processing of the public alerts. The present article reviews all the tools used by the Virgo DetChar group during the third LIGO-Virgo Observation Run (O3, from April 2019 to March 2020), mainly to analyse the Virgo data acquired at EGO. Concurrently, a companion article focuses on the results achieved by the DetChar group during the O3 run using these tools.

gr-qc

Virgo Detector Characterization and Data Quality during the O3 run

The Advanced Virgo detector has contributed with its data to the rapid growth of the number of detected gravitational-wave signals in the past few years, alongside the two LIGO instruments. First, during the last month of the Observation Run 2 (O2) in August 2017 (with, most notably, the compact binary mergers GW170814 and GW170817) and then during the full Observation Run 3 (O3): an 11 months data taking period, between April 2019 and March 2020, that led to the addition of about 80 events to the catalog of transient gravitational-wave sources maintained by LIGO, Virgo and KAGRA. These discoveries and the manifold exploitation of the detected waveforms require an accurate characterization of the quality of the data, such as continuous study and monitoring of the detector noise. These activities, collectively named {\em detector characterization} or {\em DetChar}, span the whole workflow of the Virgo data, from the instrument front-end to the final analysis. They are described in details in the following article, with a focus on the associated tools, the results achieved by the Virgo DetChar group during the O3 run and the main prospects for future data-taking periods with an improved detector.

gr-qc

The Virgo O3 run and the impact of the environment

Sources of geophysical noise (such as wind, sea waves and earthquakes) or of anthropogenic noise impact ground-based gravitational-wave interferometric detectors, causing transient sensitivity worsening and gaps in data taking. During the one year-long third Observing Run (O3: from April 01, 2019 to March 27, 2020), the Virgo Collaboration collected a statistically significant dataset, used in this article to study the response of the detector to a variety of environmental conditions. We correlated environmental parameters to global detector performance, such as observation range, duty cycle and control losses. Where possible, we identified weaknesses in the detector that will be used to elaborate strategies in order to improve Virgo robustness against external disturbances for the next data taking period, O4, currently planned to start at the end of 2022. The lessons learned could also provide useful insights for the design of the next generation of ground-based interferometers.

gr-qc

Calibration of Advanced Virgo and reconstruction of detector strain h(t) during the Observing Run O3

The three Advanced Virgo and LIGO gravitational wave detectors participated to the third observing run (O3) between 1 April 2019 15:00 UTC and 27 March 2020 17:00 UTC,leading to several gravitational wave detections per month. This paper describes the Advanced Virgo detector calibration and the reconstruction of the detector strain $h(t)$ during O3, as well as the estimation of the associated uncertainties. For the first time, the photon calibration technique as been used as reference for Virgo calibration, which allowed to cross-calibrate the strain amplitude of the Virgo and LIGO detectors. The previous reference, so-called free swinging Michelson technique, has still been used but as an independent cross-check. $h(t)$ reconstruction and noise subtraction were processed online, with good enough quality to prevent the need for offline reprocessing, except for the two last weeks of September 2019. The uncertainties for the reconstructed $h(t)$ strain, estimated in this paper in a 20-2000~Hz frequency band, are frequency independent: 5% in amplitude, 35 mrad in phase and 10 $μ$s in timing, with the exception of larger uncertainties around 50 Hz.

gr-qc

Compact Spectral Characterization of 5-500 MeV X-rays from the Texas Petawatt Laser-Driven Plasma Accelerator

We reconstruct spectra of secondary x-rays generated from a 500 MeV - 2 GeV laser plasma electron accelerator. A compact (7.5 $\times$ 7.5 $\times$ 15 cm), modular x-ray calorimeter made of alternating layers of absorbing materials and imaging plates records the single-shot x-ray depth-energy distribution. X-rays range from few-MeV inverse Compton scattered x-rays to $\sim$100 MeV average bremsstrahlung energies and are characterized individually by the same calorimeter detector. Geant4 simulations of energy deposition from mono-energetic x-rays in the stack generate an energy-vs-depth response matrix for the given stack configuration. A fast, iterative reconstruction algorithm based on analytic models of inverse Compton scattering and bremsstrahlung photon energy distributions then unfolds x-ray spectra in $\sim10$ seconds.

physics.acc-ph

The OmegaWhite survey for short-period variable stars - V. Discovery of an ultracompact hot subdwarf binary with a compact companion in a 44 minute orbit

We report the discovery of the ultracompact hot subdwarf (sdOB) binary OW J074106.0-294811.0 with an orbital period of P$_{\rm orb}=44.66279\pm1.16\times10^{-4}$ min, making it the most compact hot subdwarf binary known. Spectroscopic observations using the VLT, Gemini and Keck telescopes revealed a He-sdOB primary with an intermediate helium abundance, T$_{\rm eff}=39 400\pm500$ K and log(g)=$5.74\pm0.09$. High signal-to-noise ratio lightcurves show strong ellipsoidal modulation resulting in a derived sdOB mass $M_{\rm sdOB}=0.23\pm0.12$ M$_\odot$ with a WD companion ($M_{\rm WD}=0.72\pm0.17$ M$_\odot$). The mass ratio was found to be $q = M_{\rm sdOB}/M_{\rm WD}=0.32\pm0.10$. The derived mass for the He-sdOB is inconsistent with the canonical mass for hot sbudwarfs of $\approx0.47$ M$_\odot$. To put constraints on the structure and evolutionary history of the sdOB star we compared the derived T$_{\rm eff}$, log(g) and sdOB mass to evolutionary tracks of helium stars and helium white dwarfs calculated with Modules for Experiments in Stellar Astrophysics (MESA). We find that the best fitting model is a helium white dwarf with a mass of $0.320$ M$_\odot$, which left the common envelope ${\approx}1.1$ Myr ago, is consistent with the observations. As a helium white dwarf with a massive white dwarf companion the object will reach contact in 17.6 Myr at an orbital period of 5 min. Depending on the spin-orbit synchronization timescale the object will either merge to form an R CrB star or end up as a stably accreting AM CVn-type system with a helium white dwarf donor.

astro-ph.SR

Results of two multi-chord stellar occultations by dwarf planet (1) Ceres

We report the results of two multi-chord stellar occultations by the dwarf planet (1) Ceres that were observed from Brazil on 2010 August 17, and from the USA on 2013 October 25. Four positive detections were obtained for the 2010 occultation, and nine for the 2013 occultation. Elliptical models were adjusted to the observed chords to obtain Ceres' size and shape. Two limb fitting solutions were studied for each event. The first one is a nominal solution with an indeterminate polar aspect angle. The second one was constrained by the pole coordinates as given by Drummond et al. Assuming a Maclaurin spheroid, we determine an equatorial diameter of 972 $\pm$ 6 km and an apparent oblateness of 0.08 $\pm$ 0.03 as our best solution. These results are compared to all available size and shape determinations for Ceres made so far, and shall be confirmed by the NASA's Dawn space mission.

astro-ph.EP

Magneto-optical probe of antiferromagnetic sub-phases in a pi- d electronic system

The highly insulating antiferromagnetic phase of the magnetic- organic conductor lambda-(BETS)2FeCl4 has been probed by resonant mm wave methods vs. magnetic field, temperature, and frequency. Our results show evidence for magnetic sub-phases within the temperature-field phase diagram as previously predicted by Brossard et al. [Eur. Phys. J. B 1, 439(1998)].

cond-mat.str-el

Quadratic transverse anisotropy term due to dislocations in Mn12-Ac directly obtained by EPR spectroscopy

High-Sensitivity Electron Paramagnetic Resonance experiments have been carried out in fresh and stressed Mn12-Acetate single crystals for frequencies ranging from 40 GHz up to 110 GHz. The high number of crystal dislocations formed in the stressing process introduces a E(S_x^2-S_y^2) transverse anisotropy term in the spin hamiltonian. From the behaviour of the resonant absorptions on the applied transverse magnetic field we have obtained an average value for E = 22 mK, corresponding to a concentration of dislocations per unit cell of c = 10^-3.

cond-mat.mes-hall

Experimental observation of Frohlich superconductivity in high magnetic fields

Resistivity and irreversible magnetisation data taken within the high-magnetic-field CDWx phase of the quasi-two-dimensional organic metal alpha-(BEDT-TTF)2KHg(SCN)4 are shown to be consistent with a field-induced inhomogeneous superconducting phase. In-plane skin-depth measurements show that the resistive transition on entering the CDWx phase is both isotropic and representative of the bulk.

cond-mat.supr-con

High frequency resonant experiments in Fe$_8$ molecular clusters

Precise resonant experiments on Fe$_{8}$ magnetic clusters have been conducted down to 1.2 K at various tranverse magnetic fields, using a cylindrical resonator cavity with 40 different frequencies between 37 GHz and 110 GHz. All the observed resonances for both single crystal and oriented powder, have been fitted by the eigenstates of the hamiltonian ${\cal H}=-DS_z^2+ES_x^2-gμ_B{\bf H}\cdot {\bf S}$. We have identified the resonances corresponding to the coherent quantum oscillations for different orientations of spin S = 10.

cond-mat

NbSe3: Effect of Uniaxial Stress on the Threshold Field and Fermiology

We have measured the effect of uniaxial stress on the threshold field ET for the motion of the upper CDW in NbSe3. ET exhibits a critical behavior, ET ~ (1 - e/ec)^g, wher e is the strain, and ec is about 2.6% and g ~ 1.2. This ecpression remains valid over more than two decades of ET, up to the highest fields of about 1.5keV/m. Neither g nor ec is very sensitive to the impurity concentraction. The CDW transition temperature Tp decreases linearly with e at a rate dTp/de = -10K/%, and it does not show any anomaly near ec. Shubnikov de-Haas measurements show that the extremal area of the Fermi surface decreases with increasing strain. The results suggest that there is an intimate relationship between pinning of the upper CDW and the Fermiology of NbSe3.

cond-mat.str-el