High voltage and electrode system for a cryogenic experiment to search for the neutron electric dipole moment

The cryogenic approach to the search for the neutron electric dipole moment--performing the experiment in superfluid liquid helium--holds promise for a substantial increase in sensitivity, potentially enabling a sensitivity level of $10^{-28}$ e-cm. A crucial component in realizing such an experiment is the high voltage and electrode system capable of providing an electric field of 75 kV/cm. This, in turn, requires an electric potential of 635 kV to be applied to the high voltage electrode, while simultaneously satisfying other experimental constraints, such as those on heat load and magnetic noise requirements. This paper describes the outcome of a comprehensive development program addressing these challenges. It outlines the system requirements, discusses new insights into relevant physical phenomena, and details selected technical solutions with their corresponding experimental demonstrations and expected performance. The results collectively demonstrate the successful development of the necessary technology for the high-voltage and electrode system for this approach.

physics.ins-det

From Commissioning to Precision Data-Taking: Resolving Operational Challenges in the Nab Detector Systems

Our understanding of the weak mixing of quarks, described by the Cabibbo Kobayashi Maskawa (CKM) matrix, currently presents an anomaly. Thanks to major strides in both theory and experiment, improved precision in determinations of the first row of matrix elements has revealed disagreement with the expectation of unitarity. The Nab experiment at the Spallation Neutron Source is designed to precisely extract the first matrix element $V_{ud}$ and shed light on experimental tensions within the neutron beta decay dataset. Nab's asymmetric spectrometer allows coincident reconstruction of the decay proton and electron energies, which will be used to determine the electron-neutrino correlation coefficient, and thus (with the neutron lifetime) determine $V_{ud}$. This unique approach has provided a more comprehensive view of neutron beta decay, including a first observation of the full momentum phase space of the decay above detector thresholds and limits on exotic neutron states. Recent upgrades to the Nab detector system have improved the robustness and stability of the detector performance in terms of proton detection efficiency, noise performance, and detector segment availability, setting the stage for high precision physics data-taking.

physics.ins-det

Fundamental Nuclear and Particle Physics At Neutron Sources

Fundamental neutron and neutrino physics at neutron sources, combining precision measurements and theory, can probe new physics at energy scales well beyond the highest energies probed by the LHC and possible future high energy collider facilities. The European Spallation Source (ESS) will in the not too far future be a most powerful pulsed neutron source and simultaneously the world's brightest pulsed neutrino source. The ESS, and neutron sources in general, can provide unprecedented and unique opportunities to contribute to the search for the missing elements in the Standard Model of particle physics. Currently there are no strong indications where hints of the origin of the new physics will emerge. A multi-pronged approach will provide the fastest path to fill the gaps in our knowledge and neutron sources have a pivotal role to play. To survey the ongoing and proposed physics experiments at neutron sources and assess their potential impact, a workshop was held at Lund University in January, 2025. This report is a summary of that workshop and has been prepared as input to the European Strategy Update.

nucl-ex

Measurement of the Free Neutron Lifetime in a Magneto-Gravitational Trap with In Situ Detection

Here we publish three years of data for the UCNtau experiment performed at the Los Alamos Ultra Cold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We report a measured value for these runs from 2020-2022 for the neutron lifetime of 877.94+/-0.37 s; when all the data from UCNtau are averaged we report an updated value for the lifetime of 877.82+/-0.22 (statistical)+0.20-0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on ambient gas, and employed four different main UCN detector geometries both to reduce the correction required for rate dependence and explore potential contributions due to phase space evolution.

nucl-ex

An experimental search for an explanation of the difference between beam and bottle neutron lifetime measurements

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently published UCN aimed a searching for an explanation of this difference using the model proposed by Koch and Hummel.

nucl-ex

A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributions

We report results from a study on electrical breakdown in liquid helium using near-uniform-field stainless steel electrodes with a stressed area of $\sim$0.725 cm$^2$. The distribution of the breakdown field is obtained for temperatures between 1.7 K and 4.0 K, pressures between the saturated vapor pressure and 626 Torr, and with electrodes of different surface polishes. A data-based approach for determining the electrode-surface-area scaling of the breakdown field is presented. The dependence of the breakdown probability on the field strength as extracted from the breakdown field distribution data is used to show that breakdown is a surface phenomenon closely correlated with Fowler-Nordheim field emission from asperities on the cathode. We show that the results from this analysis provides an explanation for the supposed electrode gap-size effect and also allows for a determination of the breakdown-field distribution for arbitrary shaped electrodes. Most importantly, the analysis method presented in this work can be extended to other noble liquids to explore the dependencies for electrical breakdown in those media.

physics.ins-det

Effect of an electric field on liquid helium scintillation produced by fast electrons

The dependence on applied electric field ($0 - 40$ kV/cm) of the scintillation light produced by fast electrons and $α$ particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations, and has a dependence on the energy of the primary ionization electron. We discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.

physics.ins-det

A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.

physics.ins-det

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

nucl-ex

Using Nab to determine correlations in unpolarized neutron decay

The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.

nucl-ex

New result for the neutron $β$-asymmetry parameter $A_0$ from UCNA

The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation coefficient using ultracold neutrons (UCN). Following improvements to the systematic uncertainties and increased statistics, we report the new result $A_0 = -0.12054(44)_{\mathrm{stat}}(68)_{\mathrm{syst}}$ which yields $λ\equiv \frac{g_{A}}{g_{V}}=-1.2783(22)$. Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces $A_0=-0.12015(34)_{\mathrm{stat}}(63)_{\mathrm{syst}}$ and $λ\equiv \frac{g_{A}}{g_{V}}=-1.2772(20)$.

nucl-ex

Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$

It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.

nucl-ex

Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment

The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was $184(32)$ UCN/cm$^3$, a four-fold increase from the highest previously reported. The polarized UCN density stored in an external chamber was measured to be $39(7)$ UCN/cm$^3$, which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of $σ(d_n) = 3\times 10^{-27}$ $e\cdot$cm.

physics.ins-det

First direct constraints on Fierz interference in free neutron $β$ decay

Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.

nucl-ex

Evaluation of commercial nickel-phosphorus coating for ultracold neutron guides using a pinhole bottling method

We report on the evaluation of commercial electroless nickel phosphorus (NiP) coatings for ultracold neutron (UCN) transport and storage. The material potential of 50~$μ$m thick NiP coatings on stainless steel and aluminum substrates was measured to be $V_F = 213(5.2)$~neV using the time-of-flight spectrometer ASTERIX at the Lujan Center. The loss per bounce probability was measured in pinhole bottling experiments carried out at ultracold neutron sources at Los Alamos Neutron Science Center and the Institut Laue-Langevin. For these tests a new guide coupling design was used to minimize gaps between the guide sections. The observed UCN loss in the bottle was interpreted in terms of an energy independent effective loss per bounce, which is the appropriate model when gaps in the system and upscattering are the dominate loss mechanisms, yielding a loss per bounce of $1.3(1) \times 10^{-4}$. We also present a detailed discussion of the pinhole bottling methodology and an energy dependent analysis of the experimental results.

physics.ins-det

Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments

We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.

physics.ins-det

Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.

physics.ins-det

Measurement of spin-flip probabilities for ultracold neutrons interacting with nickel phosphorus coated surfaces

We report a measurement of the spin-flip probabilities for ultracold neutrons interacting with surfaces coated with nickel phosphorus. For 50~$μ$m thick nickel phosphorus coated on stainless steel, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;SS} = (3.3^{+1.8}_{-5.6}) \times 10^{-6}$. For 50~$μ$m thick nickel phosphorus coated on aluminum, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;Al} = (3.6^{+2.1}_{-5.9}) \times 10^{-6}$. For the copper guide used as reference, the spin flip probability per bounce was found to be $β_{\rm Cu} = (6.7^{+5.0}_{-2.5}) \times 10^{-6}$. The results on the nickel phosphorus-coated surfaces may be interpreted as upper limits, yielding $β_{\rm NiP\;on\;SS} < 6.2 \times 10^{-6}$ (90\% C.L.) and $β_{\rm NiP\;on\;Al} < 7.0 \times 10^{-6}$ (90\% C.L.) for 50~$μ$m thick nickel phosphorus coated on stainless steel and 50~$μ$m thick nickel phosphorus coated on aluminum, respectively. Nickel phosphorus coated stainless steel or aluminum provides a solution when low-cost, mechanically robust, and non-depolarizing UCN guides with a high-Fermi-potential are needed.

nucl-ex