SearcharxivSearch

arXiv subjects

J. C. Silva

Publications and source records attributed to J. C. Silva.

6 recordsLinked to original sources

Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector

For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a measurement of the time of arrival of charged particles with a precision of 30 ps at the beginning of HL-LHC, progressively degrading to 60 ps while operating in an extremely harsh radiation environment for over a decade. In this paper we present a comparative analysis of the time resolution of BTL module prototypes made of LYSO:Ce crystal bars read out by silicon photo-multipliers (SiPMs). The timing performance measured in beam test campaigns is presented for prototypes with different construction and operation parameters, such as different SiPM cell sizes (15, 20, 25 and 30 $\rm μm$), SiPM manufacturers and crystal bar thicknesses. The evolution of time resolution as a function of the irradiation level has been studied using non-irradiated SiPMs as well as SiPMs exposed up to $2\times 10^{14}~n_{eq}/cm^2$ fluence. The key parameters defining the module time resolution such as SiPM characteristics (gain, photon detection efficiency, radiation induced dark count rate) and crystal properties (light output and dimensions) are discussed. These results have informed the final choice of the MTD barrel sensor configuration and offer a unique starting point for the design of future large-area scintillator-based timing detectors in either low or high radiation environments.

physics.ins-det

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

physics.ins-det

Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.

physics.ins-det

Online energy discrimination at DAQ front-end level on pixelated TOF-PET systems

Pixelated PET systems produce higher count rates as they integrate several detecting channels per detector module. An increased data flow from the detectors posses higher needs on the bandwidth requirements. We aim to optimize the bandwidth usage efficiency by filtering on the fly the detected events with non valid energies. PET systems with a SiPM-ASIC readout scheme are being extensively used to get enhanced images on Time-Of-Flight PET scanners. These kind of digital readout systems are specially interesting for the application of on-line processing techniques given the ease of access to each detected event digital information. This study purses the analysis of on-line processing techniques on the DAQ front-end level (on-detector electronics) for pixelated PET systems with SiPM-ASIC readout. In particular, we worked with a tunable on-line energy discriminating stage. For the optimization of its hardwired internal limits we analyzed the system energy space. We explored different solutions dependent or not on the system's energy calibration. Results obtained through the different filter versions confirm the minimal resources consumption of such processing techniques implemented at DAQ front-end level. Our experiences showed how the filtering process reduces the bandwidth needs excluding from the data stream all non valid energy events and thus improving the system sensitivity under saturation conditions. Additionally, these experiments highlight how setting proper energy limits we ensure the preservation of the system performance, which maintains its original energy and time resolution. Under the light of these findings, we see a great potential on the application of on-line processing techniques for Time-Of-Flight PET at the DAQ font-end level (on-detector electronics) and so we envisaged more complex processing methods.

physics.ins-det

Detection of the Cherenkov light diffused by Sea Water with the ULTRA Experiment

The study of Ultra High Energy Cosmic Rays represents one of the most challenging topic in the Cosmic Rays and in the Astroparticle Physics fields. The interaction of primary particles with atmospheric nuclei produces a huge Extensive Air Shower together with isotropic emission of UV fluorescence light and highly directional Cherenkov photons, that are reflected/diffused isotropically by the impact on the Earth's surface or on high optical depth clouds. For space-based observations, detecting the reflected Cherenkov signal in a delayed coincidence with the fluorescence light improves the accuracy of the shower reconstruction in space and in particular the measurement of the shower maximum, giving a strong signature for discriminating hadrons and neutrinos, and helping to estimate the primary chemical composition. Since the Earth's surface is mostly covered by water, the ULTRA (UV Light Transmission and Reflection in the Atmosphere)experiment has been designed to provide the diffusing properties of sea water, overcoming the lack of information in this specific field. A small EAS array, made up of 5 particle detectors, and an UV optical device, have been coupled to detect in coincidence both electromagnetic and UV components. The detector was in operation from May to December, 2005, in a small private harbor in Capo Granitola (Italy); the results of these measurements in terms of diffusion coefficient and threshold energy are presented here.

astro-ph

Results from the ULTRA experiment in the framework of the EUSO project

The detection of Cerenkov light from EAS in a delayed coincidence with fluorescence light gives a strong signature to discriminate protons and neutrinos in cosmic rays. For this purpose, the ULTRA experiment has been designed with 2 detectors: a small EAS array (ETscope) and an UV optical device including wide field (Belenos) and narrow field (UVscope) Cerenkov light detectors. The array measures the shower size and the arrival direction of the incoming EAS, while the UV devices, pointing both to zenith and nadir, are used to determine the amount of direct and diffused coincident Cerenkov light. This information, provided for different diffusing surfaces, will be used to verify the possibility of detecting from Space the Cerenkov light produced by UHECRs with the EUSO experiment, on board the ISS.

astro-ph