SearcharxivSearch

arXiv subjects

J. Colaresi

Publications and source records attributed to J. Colaresi.

8 recordsLinked to original sources

Measurement of Coherent Elastic Neutrino-Nucleus Scattering from reactor antineutrinos

The 96.4 day exposure of a 3 kg ultra-low noise germanium detector to the high flux of antineutrinos from a power nuclear reactor is described. A very strong preference ($p<1.2\times10^{-3}$) for the presence of a coherent elastic neutrino-nucleus scattering (CE$\nu$NS) component in the data is found, when compared to a background-only model. No such effect is visible in 25 days of operation during reactor outages. The best-fit CE$\nu$NS signal is in good agreement with expectations based on a recent characterization of germanium response to sub-keV nuclear recoils. Deviations of order 60\% from the Standard Model CE$\nu$NS prediction can be excluded using present data. Standing uncertainties in models of germanium quenching factor, neutrino energy spectrum, and background are examined.

hep-ex

First results from a search for coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at a reactor site

The deployment of a low-noise 3 kg p-type point contact germanium detector at the Dresden-II power reactor, 8 meters from its 2.96 GW$_{th}$ core, is described. This location provides an unprecedented (anti)neutrino flux of 8.1$\times 10^{13} ~\bar{\nu_{e}}/$cm$^{2}$s. When combined with the 0.2 keV$_{ee}$ detector threshold achieved, a first measurement of CE$\nu$NS from a reactor source appears to be within reach. We report on the characterization and abatement of backgrounds during initial runs, deriving improved limits on extensions of the Standard Model involving a light vector mediator, from preliminary data.

hep-ex

Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data

Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.

astro-ph.CO

CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors

CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data, or the previously observed temporal variation in the event rate. Also reported on for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results

astro-ph.CO

The C-4 Dark Matter Experiment

We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to low-mass dark matter candidates to be obtained with this search.

astro-ph.CO

Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector

Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ~2.8 sigma, limited by the short exposure.

astro-ph.CO

Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector

We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.

astro-ph.CO

Experimental constraints on a dark matter origin for the DAMA annual modulation effect

A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.

astro-ph