SearcharxivSearch

arXiv subjects

J. Crofts

Publications and source records attributed to J. Crofts.

2 recordsLinked to original sources

The science of compressional heating on the LM26 magnetized target fusion experiment

The Lawson Machine 26 (LM26) at General Fusion has demonstrated compressional heating of a spherical tokamak deuterium plasma as it was compressed by an imploding solid lithium liner. Results from the first 11 compression shots on LM26 are presented, the highest-performing of which show more than a 3x increase in $T_e$, a 10x increase in $n_e$, and a 10x increase in $B_{pol}$ within the plasma driven by 3x radial compression. The experimental device and instrumentation are reviewed in detail, followed by observations about the liner trajectory and evolution of plasma properties, including increases in emission of neutrons, X-rays, and visible radiation. Observations from fast-camera images during compression provide context for interpreting the spatial structure of plasma-wall interaction. Overviews of relevant models and analysis are presented. Diagnostic data are used to reconstruct the experimental equilibrium state in computational framework as a function of time. The results build confidence in the stability and transport analyses that support the primary conclusions. Trends across the full set of 11 compression shots are presented, and detailed examinations of the high-performance shots are given individually. The central conclusions of the integrated physics model specifically indicate that compressional heating was achieved in this set of experiments, as evidenced by the balance of heating power from compression, Ohmic heating from plasma current, and losses to the boundary needed to match the experimental data. A majority of the temperature rise is attributable to compressional heating. An increase in neutron flux is also observed during compression. The results provide a basis for planned improvements to the LM26 facility that will enable the compression of magnetized plasma to increasingly higher densities and temperatures.

physics.plasm-ph

Radio path length correction using water vapour radiometry

Path length changes through the atmosphere cause significant errors for astronomical radio interferometry at high frequencies (e.g. 100 GHz). Path length differences typically give rise to a differential excess path of 1mm for antennas separated by 1km, and have fluctuation time scales of greater than 10 seconds. To measure these fluctuations, we are building a four-channel radiometer centred on the 22 GHz water line. By sensing the water vapour emission, the excess path can be deduced and corrected. Multiple channels give us robustness against various systematic errors, but gain stability of the radiometer of 1 pair in 10^4 is still required.

astro-ph