Searcharxiv⌕ Search

arXiv subjects

J. F. C. A. Veloso

Publications and source records attributed to J. F. C. A. Veloso.

At least 37 records · Page 2Linked to original sources

TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance

In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scintillation measuring systems in environmental radioactivity laboratories are sensitive to such low levels, but they are not suitable for real-time monitoring. Moreover, there is no currently available device with enough sensitivity and monitoring capabilities that could be used for surveillance of the cooling water of nuclear power plants. A detector system based on scintillation fibers read out by photomultiplier tubes (PMTs) or silicon photomultiplier (SiPM) arrays is under development for in-water tritium measurement. This detector will be installed in the vicinity of Almaraz nuclear power plant (Spain) in Spring 2019. An overview of the project development and the results of first prototypes are presented.

physics.ins-det↗

Helium-Xenon mixtures to improve topological signature in high pressure gas Xenon TPCs

Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while keeping nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15~\%, may reduce drastically the transverse diffusion down to 2.5~mm/$\sqrt{\mathrm{m}}$ from the 10.5~mm/$\sqrt{\mathrm{m}}$ of pure xenon. The longitudinal diffusion remains around 4~mm/$\sqrt{\mathrm{m}}$. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.

physics.ins-det↗

The Hybrid MPGD-based photon detectors of COMPASS RICH-1

Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.

physics.ins-det↗

Study of the loss of Xenon Scintillation in Xenon-Trimethylamine Mixtures

This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was observed experimentally. Considering the detection limit of the experimental system, if reemission by TMA molecules occurs, it is below 0.3% of the scintillation absorbed in the 160-188 nm range. An absorption coefficient value for xenon VUV light by TMA of 0.43+/-0.03 cm-1.Torr-1 was also obtained. These results can be especially important for experiments considering TMA as a molecular additive to Xe in large volume optical time projection chambers.

physics.ins-det↗

Electroluminescence TPCs at the thermal diffusion limit

The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.

physics.ins-det↗

Initial results on energy resolution of the NEXT-White detector

One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q$_{ββ}$.

physics.ins-det↗

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.

physics.ins-det↗

Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 $\pm$ 0.010 (stat.) $\pm$ 0.324 (sys.)) % FWHM in the full chamber and (3.804 $\pm$ 0.013 (stat.) $\pm$ 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into resolutions of (0.516 $\pm$ 0.0014 (stat.) $\pm$ 0.0421 (sys.)) % FWHM and (0.4943 $\pm$ 0.0017 (stat.) $\pm$ 0.0146 (sys.)) % FWHM at the $Q_{ββ}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

physics.ins-det↗

The next generation of laser spectroscopy experiments using light muonic atoms

Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with $Z \geq 3$. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen ($μ$p) and helium ($μ$$^{3}$He$^{+}$) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.

physics.atom-ph↗

The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond

After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance. Perspectives for further developments in the field of gaseous single photon detectors are also presented.

physics.ins-det↗

An EDUGATE simulation toolkit based on the educational easyPET

EasyPET is a new concept of a Positron Emission Tomography (PET) scanner using an innovative acquisition method based on two rotation axes for the movement of detector pairs. Due to its simplicity, it is suitable for education purposes, to teach students about the PET technology and its basic concepts, from the radiation detecting and analogue pulse analysis to the coincidence sorting and image reconstruction. The concept allows achieving high and uniform position resolution over the whole field of view (FoV), by eliminating parallax errors due to the depth of interaction (DoI), which are typical of ring-based PET systems, so quality images are obtained even without state-of-the-art image reconstruction algorithms. The technology developed at the University of Aveiro with a patent-pending, is licensed to CAEN S.p.A, and included in the educational catalogue of the company. In this work, a simulation toolkit based in the Edugate platform was developed to simulate the EasyPET system. It can simulate all the physical aspects of the product, such us the scanning range, variable Field-of-View (FOV), scintillator energy resolution, coincidence time and energy window, among others. A simple image reconstruction algorithm based on Filtered-back-projection (FBP) is implemented. The toolkit allows a quick analysis in classroom of the simulation results. The platform was also used to study the new EasyPET 3D version, and a simulation of a NEMA NU 4-2008 IQ phantom was performed, demonstrating the capability of the platform not only for education purposes but also for research. Patent Universidade de Aveiro: PCT/IB2016/051487

physics.med-ph↗

Electron drift properties in high pressure gaseous xenon

Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.

physics.ins-det↗

The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1

The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.

physics.ins-det↗

The Next White (NEW) detector

Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT- White (NEW) apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for $ββ0ν$ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures.

physics.ins-det↗

Line shape analysis of the K$β$ transition in muonic hydrogen

The K$β$ transition in muonic hydrogen was measured with a high-resolution crystal spectrometer. The spectrum is shown to be sensitive to the ground-state hyperfine splitting, the corresponding triplet-to-singlet ratio, and the kinetic energy distribution in the $3p$ state. The hyperfine splitting and triplet-to-singlet ratio are found to be consistent with the values expected from theoretical and experimental investigations and, therefore, were fixed accordingly in order to reduce the uncertainties in the further reconstruction of the kinetic energy distribution. The presence of high-energetic components was established and quantified in both a phenomenological, i.e. cascade-model-free fit, and in a direct deconvolution of the Doppler broadening based on the Bayesian approach.

physics.atom-ph↗

Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging

A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$σ$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

physics.ins-det↗

Measurements of charging-up processes in THGEM-based particle detectors

The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's environment, the gain stabilization process is mainly affected by the charging-up of the detector's insulating surfaces caused by the avalanche charges. The charging-up is a transient effect, occurring during the detector's initial operation period; it does not affect its long-term operation. The experimental results are consistent with the outcome of model-simulations.

physics.ins-det↗

Simulation of gain stability of THGEM gas-avalanche particle detectors

Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in relation to physical parameters. Simulation results of gain stability over time in THGEM detectors are presented, exploring the role of electrode-thickness and applied voltage on its evolution. The results show that the total amount of irradiated charge through electrode's hole needed for reaching gain stabilization is in the range of tens to hundreds of pC, depending on the detector geometry and operational voltage. These results are in agreement with experimental observations presented previously.

physics.ins-det↗