SearcharxivSearch

arXiv subjects

J. G. Robertson

Publications and source records attributed to J. G. Robertson.

At least 19 recordsLinked to original sources

Alternative approach to precision narrow-angle astrometry for Antarctic long baseline interferometry

The conventional approach to high-precision narrow-angle astrometry using a long baseline interferometer is to directly measure the fringe packet separation of a target and a nearby reference star. This is done by means of a technique known as phase-referencing which requires a network of dual beam combiners and laser metrology systems. Using an alternative approach that does not rely on phase-referencing, the narrow-angle astrometry of several closed binary stars (with separation less than 2$"$), as described in this paper, was carried out by observing the fringe packet crossing event of the binary systems. Such an event occurs twice every sidereal day when the line joining the two stars of the binary is is perpendicular to the projected baseline of the interferometer. Observation of these events is well suited for an interferometer in Antarctica. Proof of concept observations were carried out at the Sydney University Stellar Interferometer (SUSI) with targets selected according to its geographical location. Narrow-angle astrometry using this indirect approach has achieved sub-100 micro-arcsecond precision.

astro-ph.IM

Phase-referenced Interferometry and Narrow-angle Astrometry with SUSI

The Sydney University Stellar Interferometer (SUSI) now incorporates a new beam combiner, called the Microarcsecond University of Sydney Companion Astrometry instrument (MUSCA), for the purpose of high precision differential astrometry of bright binary stars. Operating in the visible wavelength regime where photon-counting and post-processing fringe tracking is possible, MUSCA will be used in tandem with SUSI's primary beam combiner, Precision Astronomical Visible Observations (PAVO), to record high spatial resolution fringes and thereby measure the separation of fringe packets of binary stars. In its current phase of development, the dual beam combiner configuration has successfully demonstrated for the first time a dual-star phase-referencing operation in visible wavelengths. This paper describes the beam combiner optics and hardware, the network of metrology systems employed to measure every non-common path between the two beam combiners and also reports on a recent narrow-angle astrometric observation of $δ$ Orionis A (HR 1852) as the project enters its on-sky testing phase.

astro-ph.IM

Long-Baseline Interferometric Multiplicity Survey of the Sco-Cen OB Association

We present the first multiplicity-dedicated long baseline optical interferometric survey of the Scorpius-Centaurus-Lupus-Crux association. We used the Sydney University Stellar Interferometer to undertake a survey for new companions to 58 Sco-Cen B- type stars and have detected 24 companions at separations ranging from 7-130mas, 14 of which are new detections. Furthermore, we use a Bayesian analysis and all available information in the literature to determine the multiplicity distribution of the 58 stars in our sample, showing that the companion frequency is F = 1.35 and the mass ratio distribution is best described as a power law with exponent equal to -0.46, agreeing with previous Sco-Cen high mass work and differing significantly from lower-mass stars in Tau-Aur. Based on our analysis, we estimate that among young B-type stars in moving groups, up to 23% are apparently single stars. This has strong implications for the understanding of high-mass star formation, which requires angular momentum dispersal through some mechanism such as formation of multiple systems.

astro-ph.SR

Optical Interferometry of early-type stars with PAVO@CHARA. I. Fundamental stellar properties

We present interferometric observations of 7 main-sequence and 3 giant stars with spectral types from B2 to F6 using the PAVO beam combiner at the CHARA array. We have directly determined the angular diameters for these objects with an average precision of 2.3%. We have also computed bolometric fluxes using available photometry in the visible and infrared wavelengths, as well as space-based ultraviolet spectroscopy. Combined with precise \textit{Hipparcos} parallaxes, we have derived a set of fundamental stellar properties including linear radius, luminosity and effective temperature. Fitting the latter to computed isochrone models, we have inferred masses and ages of the stars. The effective temperatures obtained are in good agreement (at a 3% level) with nearly-independent temperature estimations from spectroscopy. They validate recent sixth-order polynomial (B-V)-$T_\mathrm{eff}$ empirical relations \citep{Boyajian2012a}, but suggest that a more conservative third-order solution \citep{vanBelle2009} could adequately describe the (V-K)-$T_\mathrm{eff}$ relation for main-sequence stars of spectral type A0 and later. Finally, we have compared mass values obtained combining surface gravity with inferred stellar radius (\textit{gravity mass}) and as a result of the comparison of computed luminosity and temperature values with stellar evolutionary models (\textit{isochrone mass}). The strong discrepancy between isochrone and gravity mass obtained for one of the observed stars, $γ$\,Lyr, suggests that determination of the stellar atmosphere parameters should be revised.

astro-ph.SR

Starlight Demonstration of the Dragonfly Instrument: an Integrated Photonic Pupil Remapping Interferometer for High Contrast Imaging

In the two decades since the first extra-solar planet was discovered, the detection and characterization of extra-solar planets has become one of the key endeavors in all of modern science. Recently direct detection techniques such as interferometry or coronography have received growing attention because they reveal the population of exoplanets inaccessible to Doppler or transit techniques, and moreover they allow the faint signal from the planet itself to be investigated. Next-generation stellar interferometers are increasingly incorporating photonic technologies due to the increase in fidelity of the data generated. Here, we report the design, construction and commissioning of a new high contrast imager; the integrated pupil-remapping interferometer; an instrument we expect will find application in the detection of young faint companions in the nearest star-forming regions. The laboratory characterisation of the instrument demonstrated high visibility fringes on all interferometer baselines in addition to stable closure phase signals. We also report the first successful on-sky experiments with the prototype instrument at the 3.9-m Anglo-Australian Telescope. Performance metrics recovered were consistent with ideal device behaviour after accounting for expected levels of decoherence and signal loss from the uncompensated seeing. The prospect of complete Fourier-coverage coupled with the current performance metrics means that this photonically-enhanced instrument is well positioned to contribute to the science of high contrast companions.

astro-ph.IM

Multi-Dimensional Bayesian Membership Analysis of the Sco OB2 moving Group

We present a new high-mass membership of the nearby Sco OB2 association based on HIPPARCOS positions, proper motions and parallaxes and radial velocities taken from the Kharchenko et al. (2007) catalogue. The Bayesian membership selection method developed makes no distinction between subgroups of Sco OB2 and utilises linear models in calculation of membership probabilities. We select 436 members, 88 of which are new members not included in previous membership selections. We include the classical non members Alpha-Cru and Beta-Cru as new members as well as the pre-main-sequence stars HIP 79080 and 79081. We also show that the association is well mixed over distances of 8 degrees on the sky, and hence no determination can be made as to the formation process of the entire association.

astro-ph.SR

The Angular Diameter and Fundamental Parameters of Sirius A

The Sydney University Stellar Interferometer (SUSI) has been used to make a new determination of the angular diameter of Sirius A. The observations were made at an effective wavelength of 694.1 nm and the new value for the limb-darkened angular diameter is 6.048 +/- 0.040mas (+/-0.66%). This new result is compared with previous measurements and is found to be in excellent agreement with a conventionally calibrated measurement made with the European Southern Observatory's Very Large Telescope Interferometer (VLTI) at 2.176 microns (but not with a second globally calibrated VLTI measurement). A weighted mean of the SUSI and first VLTI results gives the limb-darkened angular diameter of Sirius A as 6.041 +/- 0.017mas (+/-0.28%). Combination with the Hipparcos parallax gives the radius equal to 1.713 +/- 0.009R_sun. The bolometric flux has been determined from published photometry and spectrophotometry and, combined with the angular diameter, yields the emergent flux at the stellar surface equal to (5.32+/- 0.14)x10^8 Wm^-2 and the effective temperature equal to 9845 +/- 64 K. The luminosity is 24.7 +/- 0.7 L_sun.

astro-ph.SR

Alternative Adaptive Filter Structures for Improved Radio Frequency Interference Cancellation in Radio Astronomy

In radio astronomy, reference signals from auxiliary antennas that receive only the radio frequency interference (RFI) can be modified to model the RFI environment at the astronomy receivers. The RFI can then be canceled from the astronomy signal paths. However, astronomers typically only require signal statistics. If the RFI statistics are changing slowly, the cancellation can be applied to the signal correlations at a much lower rate than is required for standard adaptive filters. In this paper we describe five canceler setups; precorrelation and postcorrelation cancelers that use one or two reference signals in different ways. The theoretical residual RFI and added noise levels are examined and are demonstrated using microwave television RFI at the Australia Telescope Compact Array. The RFI is attenuated to below the system noise, a reduction of at least 20 dB. While dual-reference cancelers add more reference noise than single-reference cancelers, this noise is zero-mean and only adds to the system noise, decreasing the sensitivity. The residual RFI that remains in the output of single-reference cancelers (but not dual-reference cancelers) sets a nonzero noise floor that does not act like random system noise and may limit the achievable sensitivity. Thus, dual-reference cancelers often result in superior cancellation. Dual-reference precorrelation cancelers require a double-canceler setup to be useful and to give equivalent results to dual-reference postcorrelation cancelers.

astro-ph.IM

Reference antenna techniques for canceling radio frequency interference due to moving sources

We investigate characteristics of radio frequency interference (RFI) signals that can affect the excision potential of some interference mitigation algorithms. The techniques considered are those that modify signals from auxiliary reference antennas to model and cancel interference from an astronomical observation. These techniques can be applied in the time domain, where the RFI voltage is modeled and subtracted from the astronomy signal path (adaptive noise canceling), or they can be applied to the autocorrelated and cross-correlated voltage spectra in the frequency domain (postcorrelation canceling). For ideal receivers and a single, statistically stationary interfering signal, both precorrelation and postcorrelation filters can result in complete cancellation of the interference from the observation. The postcorrelation method has the advantage of being applied on tens or hundreds of millisecond timescales rather than tens or hundreds of nanosecond timescales. However, this can be a disadvantage if the RFI transmitter location is changing, since the cross-correlated power measurements which link the interference power in the astronomy and reference signal paths can decorrelate. If the decorrelation is not too severe, it can be allowed for, at the expense of a noise increase. The time domain adaptive cancelers are allowed to slightly vary their internal coefficients and adapt to changing phases during the integrations, which means that they avoid the decorrelation problem. However, the freedom to adapt also results in a noise increase. In this paper the ability of both types of cancelers to excise interference originating from a moving source is compared. The cancelers perform well on both observed and simulated data, giving complete cancellation.

astro-ph.IM

Interferometric Studies of Hot Stars at Sydney University

The University of Sydney has a long history in optical stellar interferometry. The first project, in the 1960s, was the Narrabri Stellar Intensity Interferometer, which measured the angular diameters of 32 hot stars and established the temperature scale for spectral classes O - F. That instrument was followed by the Sydney University Stellar Interferometer (SUSI), which is now undergoing a third-generation upgrade, to use the multi-wavelength PAVO beam combiner. SUSI operates at visible rather than IR wavelengths and has baselines up to 160 m, so it is well suited to the study of hot stars. A number of studies have been carried out, and more are planned when commissioning of the PAVO system is complete. Conversion of the system to allow remote operation will allow larger scientific projects to be undertaken.

astro-ph.IM

Observations of the pulsation of the Cepheid l Car with the Sydney University Stellar Interferometer

Observations of the southern Cepheid l Car to yield the mean angular diameter and angular pulsation amplitude have been made with the Sydney University Stellar Interferometer (SUSI) at a wavelength of 696 nm. The resulting mean limb-darkened angular diameter is 2.990+-0.017 mas (i.e. +-0.6 per cent) with a maximum-to-minimum amplitude of 0.560+-0.018 mas corresponding to 18.7+-0.6 per cent in the mean stellar diameter. Careful attention has been paid to uncertainties, including those in measurements, in the adopted calibrator angular diameters, in the projected values of visibility squared at zero baseline, and to systematic effects. No evidence was found for a circumstellar envelope at 696 nm. The interferometric results have been combined with radial displacements of the stellar atmosphere derived from selected radial velocity data taken from the literature to determine the distance and mean diameter of l Car. The distance is determined to be 525+-26 pc and the mean radius 169+-8R{solar). Comparison with published values for the distance and mean radius show excellent agreement, particularly when a common scaling factor from observed radial velocity to pulsation velocity of the stellar atmosphere (the p-factor) is used.

astro-ph

The radius and other fundamental parameters of the F9 V star beta Virginis

We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of the F9 V star beta Virginis. After correcting for limb darkening and combining with the revised Hipparcos parallax, we derive a radius of 1.703 +/- 0.022 R_sun (1.3%). We have also calculated the bolometric flux from published measurements which, combined with the angular diameter, implies an effective temperature of 6059 +/- 49 K (0.8%). We also derived the luminosity of beta Vir to be L = 3.51 +/- 0.08 L_sun (2.1%). Solar-like oscillations were measured in this star by Carrier et al. (2005) and using their value for the large frequency separation yields the mean stellar density with an uncertainty of about 2%. Our constraints on the fundamental parameters of beta Vir will be important to test theoretical models of this star and its oscillations.

astro-ph

Getting Lucky with Adaptive Optics: Fast AO Image Selection in the Visible with a Large Telescope

We describe the results from a new instrument which combines Lucky Imaging and Adaptive Optics to give the first routine direct diffraction-limited imaging in the visible on a 5m telescope. With fast image selection behind the Palomar AO system we obtained Strehl ratios of 5-20% at 700 nm in a typical range of seeing conditions, with a median Strehl of approximately 12% when 10% of the input frames are selected. At wavelengths around 700 nm the system gave diffraction-limited 35 milliarcsecond FWHMs. At 950 nm the output Strehl ratio was as high as 36% and at 500 nm the FWHM resolution was as small as 42 milliarcseconds, with a low Strehl ratio but resolution improved by factor of ~20 compared to the prevailing seeing. To obtain wider fields we also used multiple Lucky-Imaging guide stars in a configuration similar to a ground layer adaptive optics system. With eight guide stars but very undersampled data we obtained 300 milliarcsecond resolution across a 30X30 arcsec field of view in i' band.

astro-ph

The fundamental parameters of the roAp star alpha Circini

We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of alpha Cir. This is the first detailed interferometric study of a rapidly oscillating A (roAp) star, alpha Cir being the brightest member of its class. We used the new and more accurate Hipparcos parallax to determine the radius to be 1.967+-0.066 Rs. We have constrained the bolometric flux from calibrated spectra to determine an effective temperature of 7420+-170 K. This is the first direct determination of the temperature of an roAp star. Our temperature is at the low end of previous estimates, which span over 1000 K and were based on either photometric indices or spectroscopic methods. In addition, we have analysed two high-quality spectra of alpha Cir, obtained at different rotational phases and we find evidence for the presence of spots. In both spectra we find nearly solar abundances of C, O, Si, Ca and Fe, high abundance of Cr and Mn, while Co, Y, Nd and Eu are overabundant by about 1 dex. The results reported here provide important observational constraints for future studies of the atmospheric structure and pulsation of alpha Cir.

astro-ph

The Sydney University Stellar Interferometer: A Major Upgrade to Spectral Coverage and Performance

A new beam-combination and detection system has been installed in the Sydney University Stellar Interferometer working at the red end of the visual spectrum (wavelength range 500-950 nm) to complement the existing blue-sensitive system (wavelength range 430-520 nm) and to provide an increase in sensitivity. Dichroic beam-splitters have been introduced to allow simultaneous observations with both spectral system, albeit with some restriction on the spectral range of the longer wavelength system (wavelength range 550-760 nm). The blue system has been upgraded to allow remote selection of wavelength and spectral bandpass, and to enable simultaneous operation with the red system with the latter providing fringe-envelope tracking. The new system and upgrades are described and examples of commissioning tests presented. As an illustration of the improvement in performance the measurement of the angular diameter of the southern F supergiant delta CMa is described and compared with previous determinations.

astro-ph

The Emergent Flux and Effective Temperature of Delta Canis Majoris

New angular diameter determinations for the bright southern F8 supergiant Delta CMa enable the bolometric emergent flux and effective temperature of the star to be determined with improved accuracy. The spectral flux distribution and bolometric flux have been determined from published photometry and spectrophotometry and combined with the angular diameter to derive the bolometric emergent flux F = (6.50 plus/minus 0.24) x 10^7 W/m^2 and the effective temperature Teff = 5818 plus/minus 53 K. The new value for the effective temperature is compared with previous interferometric and infrared flux method determinations. The accuracy of the effective temperature is now limited by the uncertainty in the bolometric flux rather than by the uncertainty in the angular diameter.

astro-ph

Orbital Solution & Fundamental Parameters of sigma Scorpii

The first orbital solution for the spectroscopic pair in the multiple star system sigma Scorpii, determined from measurements with the Sydney University Stellar Interferometer (SUSI), is presented. The primary component is of beta Cephei variable type and has been one of the most intensively studied examples of its class. The orbital solution, when combined with radial velocity results found in the literature, yields a distance of 174(+23,-18) pc, which is consistent with, but more accurate than the Hipparcos value. For the primary component we determine 18.4+/-5.4 M_sun, -4.12+/-0.34 mag and 12.7+/-1.8 R_sun for the mass, absolute visual magnitude and radius respectively. A B1 dwarf spectral type and luminosity class for the secondary is proposed from the mass determination of 11.9+/-3.1 M_sun and the estimated system age of 10 Myr.

astro-ph

The radius and mass of the subgiant star bet Hyi from interferometry and asteroseismology

We have used the Sydney University Stellar Interferometer (SUSI) to measure the angular diameter of beta Hydri. This star is a nearby G2 subgiant whose mean density was recently measured with high precision using asteroseismology. We determine the radius and effective temperature of the star to be 1.814+/-0.017 R_sun (0.9%) and 5872+/-44 K (0.7%) respectively. By combining this value with the mean density, as estimated from asteroseismology, we make a direct estimate of the stellar mass. We find a value of 1.07+/-0.03 M_sun (2.8%), which agrees with published estimates based on fitting in the H-R diagram, but has much higher precision. These results place valuable constraints on theoretical models of beta Hyi and its oscillation frequencies.

astro-ph