SearcharxivSearch

arXiv subjects

J. G. Shiu

Publications and source records attributed to J. G. Shiu.

3 recordsLinked to original sources

Calibration and Irradiation Study of the BGO Background Monitor for the BEAST II Experiment

Beam commissioning of the SuperKEKB collider began in 2016. The Beam Exorcism for A STable experiment II (BEAST II) project is particularly designed to measure the beam backgrounds around the interaction point of the SuperKEKB collider for the Belle II experiment. We develop a system using bismuth germanium oxide (BGO) crystals with optical fibers connecting to a multianode photomultiplier tube (MAPMT) and a field-programmable gate array (FPGA) embedded readout board for monitoring the real-time beam backgrounds in BEAST II. The overall radiation sensitivity of this system is estimated to be $(2.20\pm0.26)\times10^{-12}$ Gy/ADU (analog-to-digital unit) with the standard 10 m fibers for transmission and the MAPMT operating at 700 V. Our $γ$-ray irradiation study of the BGO system shows that the exposure of BGO crystals to $^{60}$Co $γ$-ray doses of 1 krad has led to immediate light output reductions of 25--40%, and the light outputs further drop by 30--45% after the crystals receive doses of 2--4 krad. Our findings agree with those of the previous studies on the radiation hard (RH) BGO crystals grown by the low thermal gradient Czochralski (LTG Cz) technology. The absolute dose from the BGO system is also consistent with the simulation, and is estimated to be about 1.18 times the equivalent dose. These results prove that the BGO system is able to monitor the background dose rate in real time under extreme high radiation conditions. This study concludes that the BGO system is reliable for the beam background study in BEAST II.

physics.ins-det

First study of η_c, η(1760) and X(1835) production via η'π^+π^- final states in two-photon collisions

The invariant mass spectrum of the η' π^+ π^- final state produced in two-photon collisions is obtained using a 673 fb^{-1} data sample collected in the vicinity of the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a clear signal of the η_c and measure its mass and width to be M(η_c)=(2982.7 +- 1.8(stat) +- 2.2(syst) +- 0.3(model)) MeV/c^2 and Γ(η_c) = (37.8^{+5.8}_{-5.3}(stat) +- 2.8(syst) +- 1.4(model)) MeV/c^2. The third error is an uncertainty due to possible interference between the η_c and a non-resonant component. We also report the first evidence for η(1760) decay to η' π^+ π^-; we find two solutions for its parameters, depending on the inclusion or not of the X(1835), whose existence is of marginal significance in our data. From a fit to the mass spectrum using coherent X(1835) and η(1760) resonant amplitudes, we set a 90% confidence level upper limit on the product Γ_{γγ} \BR (η' π^+ π^-) for the X(1835).

hep-ex

Design and Operation of Front-End Electronics for the HERA-B Muon Detector

We have implemented a cost-effective design for the readout electronics of both the anode wires and the cathode pads of large area proportional wire chambers for the HERA-B muon system based on the ASD-08 integrated circuit. To control and monitor the large number of readout channels, we have built a distributed control system based on Philips Semiconductors' I2C bus and microcontrollers. To date we have installed about 10800 channels of muon chambers and electronics. The average single channel noise occupancy is less than 10**-5, and the detectors have been operated with target interaction rates as high as 70 MHz.

physics.ins-det