SearcharxivSearch

arXiv subjects

J. Generowicz

Publications and source records attributed to J. Generowicz.

27 records · Page 2Linked to original sources

Demonstration of the event identification capabilities of the NEXT-White detector

In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a \TO\ calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of $71.6 \pm 1.5_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ for a background acceptance of $20.6 \pm 0.4_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies.

physics.ins-det

Radiogenic backgrounds in the NEXT double beta decay experiment

Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of (0.84$\pm$0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT Collaboration. A spectral fit to this model yields the specific contributions of $^{60}$Co, $^{40}$K, $^{214}$Bi and $^{208}$Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25$\pm$0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5$σ$ after 1 year of data taking. The background measurement in a Q$_{ββ}\pm$100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75$\pm$0.12) events.

physics.ins-det

Electron Drift and Longitudinal Diffusion in High Pressure Xenon-Helium Gas Mixtures

We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all $E/P$, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient than theoretical predictions is found at low $E/P$ in pure xenon, below the range of reduced fields usually probed by TPC experiments. A similar effect is observed in xenon-helium gas mixtures at somewhat larger $E/P$. Drift velocities in xenon-helium mixtures are found to be theoretically well predicted. Although longitudinal diffusion in xenon-helium mixtures is found to be larger than anticipated, extrapolation based on the measured longitudinal diffusion coefficients suggest that the use of helium additives to reduce transverse diffusion in xenon gas remains a promising prospect.

physics.ins-det

Electroluminescence TPCs at the thermal diffusion limit

The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.

physics.ins-det

Initial results on energy resolution of the NEXT-White detector

One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q$_{ββ}$.

physics.ins-det

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.

physics.ins-det

Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 $\pm$ 0.010 (stat.) $\pm$ 0.324 (sys.)) % FWHM in the full chamber and (3.804 $\pm$ 0.013 (stat.) $\pm$ 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into resolutions of (0.516 $\pm$ 0.0014 (stat.) $\pm$ 0.0421 (sys.)) % FWHM and (0.4943 $\pm$ 0.0017 (stat.) $\pm$ 0.0146 (sys.)) % FWHM at the $Q_{ββ}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

physics.ins-det

Electron drift properties in high pressure gaseous xenon

Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.

physics.ins-det

SEAL: Common Core Libraries and Services for LHC Applications

The CERN LHC experiments have begun the LHC Computing Grid project in 2001. One of the project's aims is to develop common software infrastructure based on a development vision shared by the participating experiments. The SEAL project will provide common foundation libraries, services and utilities identified by the project's architecture blueprint report. This requires a broad range of functionality that no individual package suitably covers. SEAL thus selects external and experiment-developed packages, integrates them in a coherent whole, develops new code for missing functionality, and provides support to the experiments. We describe the set of basic components identified by the LHC Computing Grid project and thought to be sufficient for development of higher level framework components and specializations. Examples of such components are a plug-in manager, an object dictionary, object whiteboards, an incident or event manager. We present the design and implementation of some of these components and the underlying foundation libraries in some detail.

physics.comp-ph