SearcharxivSearch

arXiv subjects

J. Hall

Publications and source records attributed to J. Hall.

At least 19 recordsLinked to original sources

Steady state, core, operational optimization of an ARC-like tokamak via plasma composition and shape

Impurity composition, plasma shape, and pedestal density all provide strong levers on fusion power. Here, we explore the ways in which their variation changes fusion power and seek to find the optimum of these parameters. The key impacts of these variables are through changes in the core turbulent transport, the density of the fuel species, the pedestal pressure, and the plasma volume. ITG stabilization due to increased amounts of impurities is observed. The dependence of all of these parameters on the pedestal pressure is especially complicated because of the separate impacts on the peeling and ballooning modes, which can each limit the pedestal. Optimization of this multidimensional operating space is enabled by the use of Bayesian optimization, resulting in an operating point similar to ARC V3A with ~30% more fusion power and a higher fusion power density. Increased shaping parameters, including elongation, triangularity, and squareness are all beneficial, as is high Zeff. When elongation is also allowed to vary, a ~65% increase in fusion power can be achieved. While not commonly considered, we find squareness is an important lever on fusion power. The plasma performance is limited by the Greenwald density limit constraint. This workflow developed here and demonstrated with the example of ARC V3A can readily be applied to other tokamak designs.

physics.plasm-ph

Radiopurity material assays and radiation exposure projections for superconducting qubit measurements at SNOLAB

Interactions of cosmic rays and other forms of ionizing radiation pose a significant challenge to the reliable operation of state-of-the-art quantum devices and error correction in quantum computing based on superconducting circuits which are typically fabricated on semiconductor substrates. Shielded by 2 km of rock overburden, the Cryogenic Underground TEst facility (CUTE) at SNOLAB provides a unique ultra-low radiation environment to probe the performance of quantum technologies with a particular interest in quantum coherence studies. In this article, we present the findings of an extensive material assaying program in preparation for the first underground operation of superconducting qubits at SNOLAB. The radioactivity levels identified by the material assays enter a thorough Monte Carlo study based on the Geant4 particle physics tracking code. From these simulations, we estimate the rates of energy deposits from radiogenic sources expected for a quantum-device assembly operated in the CUTE facility. We further characterize the spectral components of the projected background and identify the dominant particle interaction types. Finally, we outline how crystal dynamics simulations using the G4CMP solid-state physics extension for Geant4 can inform the community-wide efforts to identify effective strategies to mitigate the effects of high-energy particle impacts.

physics.ins-det

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

physics.ins-det

Impact of energetic alpha particles on core turbulence in an ARC-class fusion power plant

In this work, we investigate the impact of fusion-born alpha particles on core turbulence and transport in the ARC tokamak fusion power plant using linear and nonlinear gyrokinetic CGYRO simulations. A significant reduction in ion-scale turbulent heat and particle fluxes is observed in the inner core (r/a $\leq$ 0.5), which is associated with multiscale interactions between fast ion-destabilized modes, zonal flows, and the background turbulence. A nonlinear upshift in the ITG critical gradient is observed in the simulations with fast alphas compared to those with artificially thermalized alphas. The turbulence reduction is found to scale beneficially with alpha particle density and plasma $\beta_e$, and the radial extent of the turbulence suppression is limited to the volume containing a significant density of fast particles. The suitability of local gyrokinetics and potential impacts of fast ion effects on fusion performance are discussed.

physics.plasm-ph

Accelerating integrated modeling with surrogate-based optimization: the MAESTRO workflow

This paper introduces the MAESTRO workflow, that enables the coupling of the PORTALS framework [P. Rodriguez-Fernandez et al, Nucl. Fusion 2024] with external solvers for the plasma equilibrium, pedestal physics, divertor constraints and heating. The surrogate-based optimization nature of the transport solver is ideally suited for external coupling, allowing efficient steady-state predictions of plasma profiles with full physics models. Improvements in the surrogate modeling of quasilinear transport models with PORTALS are presented, which enable the efficient handling of discontinuities in the transport fluxes that can arise from numerical issues or physical instabilities with extreme stiffness. The combination of physics-informed methods and advanced numerical techniques allows the MAESTRO workflow to provide accurate and efficient predictions of steady-state plasma profiles, which are critical for fusion reactor design and optimization.

physics.plasm-ph

Calibration Plan for the SBC 10-kg Liquid Argon Detector with 100 eV Target Threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for $O(\mathrm{GeV}/c^{2})$ masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

physics.ins-det

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

hep-ex

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

physics.ins-det

Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution (HVeV) detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

physics.ins-det

Community Report from the 2025 SNOLAB Future Projects Workshop

SNOLAB hosts a biannual Future Projects Workshop (FPW) with the goal of encouraging future project stakeholders to present ideas, concepts, and needs for experiments or programs that could one day be hosted at SNOLAB. The 2025 FPW was held in the larger context of a 15-year planning exercise requested by the Canada Foundation for Innovation. This report collects input from the community, including both contributions to the workshop and contributions that could not be scheduled in the workshop but nonetheless are important to the community.

hep-ex

Applying Geant4's Importance Biasing to improve the efficiency of SuperCDMS background simulations

Experiments searching for extremely rare events surround their sensitive detectors with several layers of different shielding materials to protect them from external radiation and to achieve their low-background requirements to be able to observe a potential signal. Standard Monte Carlo simulations that propagate particles through the thick shielding, usually do not penetrate the shield in sufficient numbers to properly model the external background, which is crucial for understanding the experiment's background composition. Geant4 is a widely used toolkit to simulate the passage of particles through matter and it offers various biasing techniques, among them being importance biasing, which has been intensively explored for application in background simulations for the SuperCDMS experiment. In this article, the basic working principle of importance biasing is explained. Furthermore, we provide guidance for developers for their own implementation of a biasing scheme. A new track property, the "biasing index", is introduced to allow different track topologies to be distinguished. Validation studies and optimal parameters for biasing gammas and neutrons are presented and caveats are discussed. In this work, simulations run with importance biasing achieved an efficiency boost of about $\mathcal{O}(10^4)$ for gammas and up to 500 for neutrons. By applying these techniques, we show that energy distributions simulated with and without importance biasing are consistent with each other within statistical uncertainty at a fraction of the consumed computing time.

hep-ex

Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $\gamma$-ray interactions. This paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ~1 keV nuclear recoils while remaining insensitive to bubble nucleation by $\gamma$-rays. A robust calibration of the chamber's nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by $\gamma$-ray-induced Auger cascades, with a limit of $<1.1\times10^{-6}$ set at 0.50 keV, the lowest thermodynamic threshold explored.

physics.ins-det

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex

Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage ($V_{\text{BD}}$), the SiPM gain ($g_{\text{SiPM}}$), the rate of change of $g_{\text{SiPM}}$ with respect to voltage ($m$), the dark count rate (DCR), and the probability of a correlated avalanche (P$_{\text{CA}}$) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to $233.15\pm0.2$~K and $255.15\pm0.2$~K with average stability of $\pm20$~mK. An analysis framework was developed to estimate $V_{\text{BD}}$ to tens of mV precision and DCR close to Poissonian error. The temperature dependence of $V_{\text{BD}}$ was found to be $56\pm2$~mV~K$^{-1}$, and $m$ on average across all Quads was found to be $(459\pm3(\rm{stat.})\pm23(\rm{sys.}))\times 10^{3}~e^-$~PE$^{-1}$~V$^{-1}$. The average DCR temperature coefficient was estimated to be $0.099\pm0.008$~K$^{-1}$ corresponding to a reduction factor of 7 for every 20~K drop in temperature. The average temperature dependence of P$_{\text{CA}}$ was estimated to be $4000\pm1000$~ppm~K$^{-1}$. P$_{\text{CA}}$ estimated from the average across all SiPMs is a better estimator than the P$_{\text{CA}}$ calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

physics.ins-det

Multicomponent Activity Cycles using Hilbert-Huang Analysis

The temporal analysis of stellar activity evolution is usually dominated by a complex trade-off between model complexity and interpretability, often by neglecting the non-stationary nature of the process. Recent studies appear to indicate that the presence of multiple coexisting cycles in a single star is more common than previously thought. The correct identification of physically meaningful cyclic components in spectroscopic time series is therefore a crucial task, which cannot overlook local behaviors. Here we propose a decomposition technique which adaptively recovers amplitude- and frequency-varying components. We present our results for the solar activity as measured both by the sunspot number and the $K$-line emission index, and we consistently recover the Schwabe and Gleissberg cycles as well as the Gnevyshev-Ohl pattern probably related to the Hale cycle. We also recover the known 8-year cycle for 61 Cygni A, in addition to evidence of a three-cycles long pattern reminiscent of the Gnevyshev-Ohl rule. This is particularly interesting as we cannot discard the possibility of a relationship between the measured field polarity reversals and this Hale-like periodicity.

astro-ph.SR

Evaluation of SNOLAB background mitigation procedures through the use of an ICP-MS based dust monitoring methodology

Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. In this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB, and informs dust backgrounds during laboratory activities. Fallout rates of major constituent of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. A ca. two order of magnitude increase in stable Pb fallout rate was determined in an experimental area during activities involving handling of Pb bricks. Increased K-40, Th-232, and U-238 fallout rates were measured in clean experimental areas during activities generating particulate.

physics.ins-det

First measurement of the nuclear-recoil ionization yield in silicon at 100 eV

We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

physics.ins-det

A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS

We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.

hep-ex