SearcharxivSearch

arXiv subjects

J. Hollar

Publications and source records attributed to J. Hollar.

6 recordsLinked to original sources

Properties of carbon-infused silicon LGAD devices after non-uniform irradiation with 24 GeV/c protons

Forward proton spectrometers at high-energy proton colliders rely on precision timing to discriminate signal from background. Silicon low gain avalanche diodes (LGADs) are a candidate for future timing detectors in these systems. A major challenge for the use of LGADs is that these detectors must be placed within a few mm of the beams, resulting in a very large and highly non-uniform radiation environment. We present a first measurement of the current and capacitance vs. voltage behavior of LGAD sensors, after a highly non-uniform irradiation with beams of 24 GeV/c protons at fluences up to $1\times10^{16} p/cm^{2}$.

physics.ins-det

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

physics.ins-det

LHC Forward Physics

The goal of this report is to give a comprehensive overview of the rich field of forward physics, with a special attention to the topics that can be studied at the LHC. The report starts presenting a selection of the Monte Carlo simulation tools currently available, chapter 2, then enters the rich phenomenology of QCD at low, chapter 3, and high, chapter 4, momentum transfer, while the unique scattering conditions of central exclusive production are analyzed in chapter 5. The last two experimental topics, Cosmic Ray and Heavy Ion physics are presented in the chapter 6 and 7 respectively. Chapter 8 is dedicated to the BFKL dynamics, multiparton interactions, and saturation. The report ends with an overview of the forward detectors at LHC. Each chapter is correlated with a comprehensive bibliography, attempting to provide to the interested reader with a wide opportunity for further studies.

hep-ph

$γγ$ and $γp$ measurements with forward proton taggers in CMS+TOTEM

The CMS+TOTEM Precision Proton Spectrometer operated for the first time in 2016, collecting data during $pp$ collisions at $\sqrt{s} = 13$ TeV at the CERN Large Hadron Collider. Procedures for the detector alignment, optics corrections, and background estimations were developed, and applied to an analysis of the process $pp \rightarrow p μ^{+}μ^{-} p^{(*)}$ with dimuon masses larger than 110 GeV. A total of 12 candidate events are observed, corresponding to an excess of $>4σ$ over the background prediction. This constitutes the first evidence for this process at such masses, and demonstrates the good performance of CT-PPS.

hep-ex

Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.

physics.ins-det