Quality control and quality assurance evaluation of ALFE2, a large-dynamic-range front-end ASIC de-veloped for the ATLAS Liquid Argon Calorimeter high-luminosity LHC upgrade

ALFE2 is a front-end ASIC developed for the ATLAS Liquid Argon (LAr) Calorimeter upgrade during the High-Luminosity Large Hadron Collider (HL-LHC) phase. ALFE2 comprises four preamplifier/shaper channels, each providing two distinct gain outputs to cover a 16-bit dynamic range. A robotic system has been developed for the automatic quality control test of ALFE2, and over 10% of the 80,000 chips have been evaluated by September 2025. The evaluation has allowed us to establish grading criteria. Using these criteria, a yield of over 85% was achieved in the evaluation tests, and these criteria are now being applied to the ongoing full-production QC. Irradiation tests were also performed for the quality assurance of ALFE2. No significant performance degradation was observed during the total-ionizing-dose (TID) test. Based on the single-event effect (SEE) test results, an error rate of fewer than 4.6 single-event upsets (SEUs) per day is extrapolated for the entire ATLAS LAr Calorimeter during HL-LHC operation.

physics.ins-det

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC)2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

physics.ins-det

A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers

The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at Brookhaven National Lab and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10$^8$ n/cm$^2$ to 10$^{12}$ n/cm$^2$. The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This study was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.

physics.ins-det