Searcharxiv⌕ Search

arXiv subjects

J. Kim

Publications and source records attributed to J. Kim.

At least 55 records · Page 3Linked to original sources

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of $^{125}$Xe and $^{127}$Xe, and double-electron-capture decays of $^{124}$Xe, are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy $β$ decays, and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1~keV M-shell, 5.2~keV L-shell, and 33.2~keV K-shell at drift fields of 193 and 96.5~V/cm. The LL double-electron-capture decay of $^{124}$Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

hep-ex↗

First constraint for atmospheric millicharged particles with the LUX-ZEPLIN experiment

We report on a search for millicharged particles (mCPs) produced in cosmic ray proton atmospheric interactions using data collected during the first science run of the LUX-ZEPLIN experiment. The mCPs produced by two processes -- meson decay and proton bremsstrahlung -- are considered in this study. This search utilized a novel signature unique to liquid xenon (LXe) time projection chambers (TPCs), allowing sensitivity to mCPs with masses ranging from 10 to 1000 MeV/c$^2$ and fractional charges between 0.001 and 0.02 of the electron charge e. With an exposure of 60 live days and a 5.5 tonne fiducial mass, we observed no significant excess over background. This represents the first experimental search for atmospheric mCPs and the first search for mCPs using an underground LXe experiment.

hep-ex↗

New constraints on cosmic ray-boosted dark matter from the LUX-ZEPLIN experiment

While dual-phase xenon time projection chambers (TPCs) have driven the sensitivity towards weakly interacting massive particles (WIMPs) at the GeV/c^2 to TeV/c^2 mass scale, the scope for sub-GeV/c^2 dark matter particles is hindered by a limited nuclear recoil energy detection threshold. One approach to probe for lighter candidates is to consider cases where they have been boosted by collisions with cosmic rays in the Milky Way, such that the additional kinetic energy lifts their induced signatures above the nominal threshold. In this Letter, we report first results of a search for cosmic ray-boosted dark matter (CRDM) with a combined 4.2 tonne-year exposure from the LUX-ZEPLIN (LZ) experiment. We observe no excess above the expected backgrounds and establish world-leading constraints on the spin-independent CRDM-nucleon cross section as small as 3.9 * 10^{-33} cm^2 at 90% confidence level for sub-GeV/c^2 masses.

hep-ex↗

CHEX-MATE: The Impact of Triaxiality and Orientation on Planck SZ Cluster Selection and Weak Lensing Mass Measurements

Galaxy cluster abundance measurements are a valuable tool for constraining cosmological parameters like the mass density ($Ω_m$) and density fluctuation amplitude ($σ_8$). Wide area surveys detect clusters based on observables, such as the total integrated Sunyaev-Zel'dovich effect signal ($Y_{SZ}$) in the case of Planck. Quantifying the survey selection function is necessary for a cosmological analysis, with completeness representing the probability of detecting a cluster as a function of its intrinsic properties. Employing a Monte-Carlo method, we inject triaxial cluster profiles into random positions within the Planck all-sky maps, and subsequently determine the completeness of the Planck-selected CHEXMATE sample as a function of both geometry and SZ brightness. This is then used to generate 1000 mock CHEX-MATE cluster catalogs, and the distribution of shapes and orientations of the detected clusters, along with any associated bias in weak lensing-derived mass ($M_{WL}$) due to this orientation-dependent selection, denoted as $1 - b_χ$, is obtained. We show that cluster orientation impacts completeness, with a higher probability of detecting clusters elongated along the line of sight (LOS). This leads to $1 - b_χ$ values of $0-4\%$ for CHEXMATE clusters relative to a random population. The largest increase in $M_{WL}$ is observed in the lowest mass objects, which are most impacted by orientation-related selection bias. This bias is relevant for upcoming SZ surveys like CMB-S4, and should be considered for surveys utilizing other probes for cluster detection, such as Euclid.

astro-ph.CO↗

Isomer-selective dissociation dynamics of 1,2-dibromoethene ionized by femtosecond-laser radiation

We study the isomer-specific photoionization and photofragmentation of 1,2- dibromoethene (DBE) under strong-field fs-laser irradiation in the gas phase complementing previous studies utilising ns- and ps-laser excitation. Our findings are compatible with a dissociative multiphoton-ionization mechanism producing a variety of ionic photofragments. Using both Stark deflection and chemical separation of the two isomers, pronounced isomer-specific photofragmentation dynamics could be observed for different product channels. While for Br+ formation, the isomer specificity appears to originate from different photoexcitation efficiencies, for the C2H2Br+ channel it is more likely caused by differences in the coupling to the exit channel. By contrast, the formation of the C2H2+ photofragment does not seem to exhibit a pronounced isomeric dependence under the present conditions. The present work underlines the importance of isomeric effects in photochemistry even in small polyatomics like the present system as well as their pronounced dependence on the photoexcitation conditions.

physics.chem-ph↗

CHEX-MATE: Multi-probe analysis of Abell 1689

The nature of the elusive dark matter can be probed by comparing the predictions of the cold dark matter framework with the gravitational field of massive galaxy clusters. However, a robust test of dark matter can only be achieved if the systematic uncertainties in the reconstruction of the gravitational potential are minimized. Techniques based on the properties of intracluster gas rely on the assumption that the gas is in hydrostatic equilibrium within the potential well, whereas gravitational lensing is sensitive to projection effects. Here we attempt to minimize systematics in galaxy cluster mass reconstructions by jointly exploiting the weak gravitational lensing signal and the properties of the hot intracluster gas determined from X-ray and millimeter (Sunyaev-Zel'dovich) observations. We construct a model to fit the multi-probe information within a common framework, accounting for non-thermal pressure support and elongation of the dark matter halo along the line of sight. We then apply our framework to the massive cluster Abell 1689, which features unparalleled multi-wavelength data. In accordance with previous works, we find that the cluster is significantly elongated along the line of sight. Accounting for line-of-sight projections, we require a non-thermal pressure support of $30\text{-}40\%$ at $r_{500}$ to match the gas and weak lensing observables. The joint model retrieves a concentration $c_{200}\sim7$, which is lower and more realistic than the high concentration retrieved from weak lensing data alone under the assumption of spherical symmetry ($c_{200}\sim15$). Application of our method to a larger sample will allow us to study at the same time the shape of dark matter mass profiles and the level of non-thermal pressure support in galaxy clusters.

astro-ph.CO↗

Upgrading the COSINE-100 Experiment for Enhanced Sensitivity to Low-Mass Dark Matter Detection

The DAMA/LIBRA experiment has reported an annual modulation signal in NaI(Tl) detectors, which has been interpreted as a possible indication of dark matter interactions. However, this claim remains controversial, as several experiments have tested the modulation signal using NaI(Tl) detectors. Among them, the COSINE-100 experiment, specifically designed to test DAMA/LIBRA's claim, observed no significant signal, revealing a more than 3 $σ$ discrepancy with DAMA/LIBRA's results. Here we present COSINE-100U, an upgraded version of the experiment, which aims to expand the search for dark matter interactions by improving light collection efficiency and reducing background noise. The detector, consisting of eight NaI(Tl) crystals with a total mass of 99.1 kg, has been relocated to Yemilab, a new underground facility in Korea, and features direct PMT-coupling technology to enhance sensitivity. These upgrades significantly improve the experiment's ability to probe low-mass dark matter candidates, contributing to the ongoing global effort to clarify the nature of dark matter.

hep-ex↗

Square Kilometre Array Science Data Challenge 3a: foreground removal for an EoR experiment

We present and analyse the results of the Science data challenge 3a (SDC3a, https://sdc3.skao.int/challenges/foregrounds), an EoR foreground-removal community-wide exercise organised by the Square Kilometre Array Observatory (SKAO). The challenge ran for 8 months, from March to October 2023. Participants were provided with realistic simulations of SKA-Low data between 106 MHz and 196 MHz, including foreground contamination from extragalactic as well as Galactic emission, instrumental and systematic effects. They were asked to deliver cylindrical power spectra of the EoR signal, cleaned from all corruptions, and the corresponding confidence levels. Here we describe the approaches taken by the 17 teams that completed the challenge, and we assess their performance using different metrics. The challenge results provide a positive outlook on the capabilities of current foreground-mitigation approaches to recover the faint EoR signal from SKA-Low observations. The median error committed in the EoR power spectrum recovery is below the true signal for seven teams, although in some cases there are some significant outliers. The smallest residual overall is $4.2_{-4.2}^{+20} \times 10^{-4}\,\rm{K}^2h^{-3}$cMpc$^{3}$ across all considered scales and frequencies. The estimation of confidence levels provided by the teams is overall less accurate, with the true error being typically under-estimated, sometimes very significantly. The most accurate error bars account for $60 \pm 20$\% of the true errors committed. The challenge results provide a means for all teams to understand and improve their performance. This challenge indicates that the comparison between independent pipelines could be a powerful tool to assess residual biases and improve error estimation.

astro-ph.IM↗

The T-SDHCAL Hadronic Calorimeter for a Future Higgs factory

The CALICE technological RPC-based SDHCAL prototype that fullfils all the requirements of compactness, hermeticity and power budget of the future lepton accelerator experiments, has been extensively tested and has provided excellent results in terms of the energy resolution and shower separation. A new phase of R&D to validate completely the SDHCAL option for the International Linear Detector (ILD) project of the ILC and also the Circular Electron Positron Collider (CEPC and FCCee) has started with the conception and the realization of new prototypes. The new prototype proposes to exploit the excellent time resolution that can be provided by multi-gap resistive plate chamber detectors in order to better build the hadronic showers with the aim to separate close-by ones and also to single out the contribution of delayed neutrons with the purpose to improve on the Particle Flow Algorithm performances and better reconstruct the showers energy. A new technique to build multi-gap resistive plate chambers has been developed and first results confirm the excellent efficiency of the new detectors. The timing performance is under study using the PETIROC ASIC developed by the OMEGA group. The progress realized on the different aspects of the new concept will be presented and the future steps will be discussed.

physics.ins-det↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser-ablation up to pressures above 135~GPa. We hence deduce the x-ray Debye-Waller (DW) factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density (HED) endstation of the European X-ray Free-Electron Laser (EuXFEL). Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering), and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and, allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer, provides a reliable measurement of $T/Θ_D^2$, where $Θ_D$ is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper, and find good agreement within experimental errors. We thus demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radation.

cond-mat.mtrl-sci↗

COMAP Pathfinder -- Season 2 results I. Improved data selection and processing

The CO Mapping Array Project (COMAP) Pathfinder is performing line intensity mapping of CO emission to trace the distribution of unresolved galaxies at redshift $z \sim 3$. We present an improved version of the COMAP data processing pipeline and apply this to the first two seasons of observations. This analysis improves on the COMAP Early Science (ES) results in several key aspects. On the observational side, all second season scans were made in constant-elevation mode, after noting that the previous Lissajous scans were associated with increased systematic errors; those scans accounted for 50% of the total Season 1 data volume. Secondly, all new observations were restricted to an elevation range of 35-65 degrees, to minimize sidelobe ground pickup. On the data processing side, more effective data cleaning in both the time- and map-domain has allowed us to eliminate all data-driven power spectrum-based cuts. This increases the overall data retention and reduces the risk of signal subtraction bias. On the other hand, due to the increased sensitivity, two new pointing-correlated systematic errors have emerged, and we introduce a new map-domain PCA filter to suppress these. Subtracting only 5 out of 256 PCA modes, we find that the standard deviation of the cleaned maps decreases by 67% on large angular scales, and after applying this filter, the maps appear consistent with instrumental noise. Combining all these improvements, we find that each hour of raw Season 2 observations yields on average 3.2 times more cleaned data compared to ES analysis. Combining this with the increase in raw observational hours, the effective amount of data available for high-level analysis is a factor of 8 higher than in ES. The resulting maps have reached an uncertainty of $25$-$50\,μK$ per voxel, providing by far the strongest constraints on cosmological CO line emission published to date.

astro-ph.CO↗

Lowering threshold of NaI(Tl) scintillator to 0.7 keV in the COSINE-100 experiment

COSINE-100 is a direct dark matter search experiment, with the primary goal of testing the annual modulation signal observed by DAMA/LIBRA, using the same target material, NaI(Tl). In previous analyses, we achieved the same 1 keV energy threshold used in the DAMA/LIBRA's analysis that reported an annual modulation signal with 11.6$σ$ significance. In this article, we report an improved analysis that lowered the threshold to 0.7 keV, thanks to the application of Multi-Layer Perception network and a new likelihood parameter with waveforms in the frequency domain. The lower threshold would enable a better comparison of COSINE-100 with new DAMA results with a 0.75 keV threshold and account for differences in quenching factors. Furthermore the lower threshold can enhance COSINE-100's sensitivity to sub-GeV dark matter searches.

hep-ex↗

COMAP Pathfinder -- Season 2 results II. Updated constraints on the CO(1-0) power spectrum

We present updated constraints on the cosmological 3D power spectrum of carbon monoxide CO(1-0) emission in the redshift range $2.4$-$3.4$. The constraints are derived from the two first seasons of Carbon monOxide Mapping Array Project (COMAP) Pathfinder line-intensity mapping observations aiming to trace star-formation during the Epoch of Galaxy Assembly. These results improve on the previous Early Science (ES) results through both increased data volume and improved data processing methodology. On the methodological side, we now perform cross-correlations between groups of detectors (''feed-groups''), as opposed to cross-correlations between single feeds, and this new feed-group pseudo power spectrum (FGPXS) is constructed to be more robust against systematic effects. In terms of data volume, the effective mapping speed is significantly increased due to an improved observational strategy as well as better data selection methodology. The updated spherically- and field-averaged FGPXS, $\tilde{C}(k)$, is consistent with zero, at a probability-to-exceed of around $34\,\%$, with an excess of $2.7\,σ$ in the most sensitive bin. Our power spectrum estimate is about an order of magnitude more sensitive in our six deepest bins across ${0.09\,\mathrm{Mpc}^{-1} < k < 0.73\,\mathrm{Mpc}^{-1}}$, as compared to the feed-feed pseudo power spectrum (FPXS) of COMAP ES. Each of these bins individually constrains the CO power spectrum to ${kP_\mathrm{CO}(k)< 2400-4900\,\mathrm{μK^2 Mpc^{2}}}$ at $95\,\%$ confidence. To monitor potential contamination from residual systematic effects, we analyze a set of 312 difference-map null tests and find that these are consistent with the instrumental noise prediction. In sum, these results provide the strongest direct constraints on the cosmological 3D CO(1-0) power spectrum published to date.

astro-ph.CO↗

Two-neutrino double electron capture of $^{124}$Xe in the first LUX-ZEPLIN exposure

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double electron capture (2$ν$2EC), utilizing a $1.39\,\mathrm{kg} \times \mathrm{yr}$ isotopic exposure from the first LZ science run. A half-life of $T_{1/2}^{2\nu2\mathrm{EC}} = (1.09 \pm 0.14_{\text{stat}} \pm 0.05_{\text{sys}}) \times 10^{22}\,\mathrm{yr}$ is observed with a statistical significance of $8.3\,σ$, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the $1.4\,σ$ level.

nucl-ex↗

Performance of the prototype beam drift chamber for LAMPS at RAON with proton and Carbon-12 beams

Beam Drift Chamber (BDC) is designed to reconstruct the trajectories of incident rare isotope beams provided by RAON (Rare isotope Accelerator complex for ON-line experiments) into the experimental target of LAMPS (Large Acceptance Multi-Purpose Spectrometer). To conduct the performance test of the BDC, the prototype BDC (pBDC) is manufactured and evaluated with the high energy ion beams from HIMAC (Heavy Ion Medical Accelerator in Chiba) facility in Japan. Two kinds of ion beams, 100 MeV proton, and 200 MeV/u $^{12}$C, have been utilized for this evaluation, and the track reconstruction efficiency and position resolution have been measured as the function of applied high voltage. This paper introduces the construction details and presents the track reconstruction efficiency and position resolution of pBDC.

physics.ins-det↗

Explainability of Deep Neural Networks for Brain Tumor Detection

Medical image classification is crucial for supporting healthcare professionals in decision-making and training. While Convolutional Neural Networks (CNNs) have traditionally dominated this field, Transformer-based models are gaining attention. In this study, we apply explainable AI (XAI) techniques to assess the performance of various models on real-world medical data and identify areas for improvement. We compare CNN models such as VGG-16, ResNet-50, and EfficientNetV2L with a Transformer model: ViT-Base-16. Our results show that data augmentation has little impact, but hyperparameter tuning and advanced modeling improve performance. CNNs, particularly VGG-16 and ResNet-50, outperform ViT-Base-16 and EfficientNetV2L, likely due to underfitting from limited data. XAI methods like LIME and SHAP further reveal that better-performing models visualize tumors more effectively. These findings suggest that CNNs with shallower architectures are more effective for small datasets and can support medical decision-making.

cs.CV↗

The Design, Implementation, and Performance of the LZ Calibration Systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

physics.ins-det↗

Improved background modeling for dark matter search with COSINE-100

COSINE-100 aims to conclusively test the claimed dark matter annual modulation signal detected by DAMA/LIBRA collaboration. DAMA/LIBRA has released updated analysis results by lowering the energy threshold to 0.75 keV through various upgrades. They have consistently claimed to have observed the annual modulation. In COSINE-100, it is crucial to lower the energy threshold for a direct comparison with DAMA/LIBRA, which also enhances the sensitivity of the search for low-mass dark matter, enabling COSINE-100 to explore this area. Therefore, it is essential to have a precise and quantitative understanding of the background spectrum across all energy ranges. This study expands the background modeling from 0.7 to 4000 keV using 2.82 years of COSINE-100 data. The modeling has been improved to describe the background spectrum across all energy ranges accurately. Assessments of the background spectrum are presented, considering the nonproportionality of NaI(Tl) crystals at both low and high energies and the characteristic X-rays produced by the interaction of external backgrounds with materials such as copper. Additionally, constraints on the fit parameters obtained from the alpha spectrum modeling fit are integrated into this model. These improvements are detailed in the paper.

astro-ph.IM↗