SearcharxivSearch

arXiv subjects

J. Klose

Publications and source records attributed to J. Klose.

3 recordsLinked to original sources

High-accuracy multi-ion spectroscopy with mixed-species Coulomb crystals

Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock ions in a linear Coulomb crystal, sympathetically cooled with ${}^{172}$Yb${}^+$ ions. In first clock comparisons, we see agreement below $1\times10^{-17}$ with results obtained using a single In${}^+$ ion, for which we have evaluated the systematic uncertainty to be $2.5\times10^{-18}$. Operation with four clock ions reduces the instability from $1.6\times10^{-15}/\sqrt{t/(1\;\mathrm{s})}$ to $9.2\times10^{-16}/\sqrt{t/(1\;\mathrm{s})}$. We derive a model for decay-related dead time during state preparation, which matches the observed scaling of instability with clock ion number $N$, and indicates that $1/\sqrt{N}$ scaling can be achieved with the addition of a repump laser.

physics.atom-ph

$^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty

We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{τ/1\;\mathrm{s}}$. We report on absolute frequency measurements with an uncertainty of $1.3\times10^{-16}$ and optical frequency comparisons with clocks based on $^{171}$Yb$^+$ (E3) and $^{87}$Sr. With a fractional uncertainty of $4.4\times10^{-18}$, the former is - to our knowledge - the most accurate frequency ratio value reported to date. For the $^{115}$In$^+$/$^{87}$Sr ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{τ/1\;\mathrm{s}}$.

physics.atom-ph

Improved limits on the coupling of ultralight bosonic dark matter to photons from optical atomic clock comparisons

We present improved constraints on the coupling of ultralight bosonic dark matter to photons based on long-term measurements of two optical frequency ratios. In these optical clock comparisons, we relate the frequency of the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric-octupole (E3) transition in $^{171}$Yb$^{+}$ to that of the ${}^2S_{1/2} (F=0)\leftrightarrow \,{}^2D_{3/2} (F=2)$ electric-quadrupole (E2) transition of the same ion, and to that of the ${}^1S_0\leftrightarrow\,{}^3P_0$ transition in $^{87}$Sr. Measurements of the first frequency ratio $ν_\textrm{E3}/ν_\textrm{E2}$ are performed via interleaved interrogation of both transitions in a single ion. The comparison of the single-ion clock based on the E3 transition with a strontium optical lattice clock yields the second frequency ratio $ν_\textrm{E3}/ν_\textrm{Sr}$. By constraining oscillations of the fine-structure constant $α$ with these measurement results, we improve existing bounds on the scalar coupling $d_e$ of ultralight dark matter to photons for dark matter masses in the range of about $ 10^{-24}-10^{-17}\,\textrm{eV}/c^2$. These results constitute an improvement by more than an order of magnitude over previous investigations for most of this range. We also use the repeated measurements of $ν_\textrm{E3}/ν_\textrm{E2}$ to improve existing limits on a linear temporal drift of $α$ and its coupling to gravity.

physics.atom-ph