Searcharxiv⌕ Search

arXiv subjects

J. Krämer

Publications and source records attributed to J. Krämer.

8 recordsLinked to original sources

Collinear Laser Spectroscopy on a Fast Atomic Beam of Boron Generated by Photodetachment of Accelerated B- Ions

Atomic beams for collinear laser spectroscopy are typically produced via charge exchange reactions in an in-beam vapor cell. This process is accompanied by the formation of a considerable amount of longer-lived excited state population, which is not accessible for spectroscopy and also induces fluorescence background to photon detectors. We present an alternative method to produce an atomic beam, consisting exclusively of ground-state atoms. Negative ions are neutralized in-flight by photodetachment and are subsequently used for fluorescence spectroscopy. As a test candidate, a negative boron ion beam was produced in a cesium sputtering source and superimposed with a co-propagating high-power pulsed infrared laser. The neutral atoms were subsequently excited along the $2s^2 2p\,{}^{2\!}P_{1/2,3/2} \rightarrow 2s^2 3s\,{}^{2\!}S_{1/2}$ transitions by a continuous-wave laser at about 250 nm. The statistics and efficiency were limited by the combination of a continuous ion beam with a low-repetition-rate laser, but a clear route for the improvement combining existing techniques is presented, which can then be applied to other elements as well as negative molecular ions.

physics.atom-ph↗

Charge radii of neutron-rich scandium isotopes and the seniority symmetry in the $0f_{7/2}$ shell

Nuclear charge radii of neutron-rich $^{47-49}$Sc isotopes were measured using collinear laser spectroscopy at CERN-ISOLDE. The new data reveal that the charge radii of scandium isotopes exhibit a distinct trend between $N=20$ and $N=28$, with $^{41}$Sc and $^{49}$Sc isotopes having similar values, mirroring the closeness of the charge radii of $^{40}$Ca and $^{48}$Ca. Theoretical models that successfully interpret the radii of calcium isotopes could not account for the observed behavior in scandium radii, in particular the reduced odd-even staggering. Remarkably, the inclusion of the new $^{49}$Sc radius data has unveiled a similar trend in the charge radii of $N=28$ isotones and $Z=20$ isotopes when adding the neutrons atop the $^{40}$Ca core and the protons atop the $^{48}$Ca core, respectively. We demonstrate that this trend is consistent with the prediction of the seniority model.

nucl-ex↗

Electromagnetic moments of scandium isotopes and $N=28$ isotones in the distinctive $0f_{7/2}$ orbit

The electric quadrupole moment of $^{49}$Sc was measured by collinear laser spectroscopy at CERN-ISOLDE to be $Q_{\rm s}=-0.159(8)$ $e$b, and a nearly tenfold improvement in precision was reached for the electromagnetic moments of $^{47,49}$Sc. The single-particle behavior and nucleon-nucleon correlations are investigated with the electromagnetic moments of $Z=21$ isotopes and $N=28$ isotones as valence neutrons and protons fill the distinctive $0f_{7/2}$ orbit, respectively, located between magic numbers, 20 and 28. The experimental data are interpreted with shell-model calculations using an effective interaction, and ab-initio valence-space in-medium similarity renormalization group calculations based on chiral interactions. These results highlight the sensitivity of nuclear electromagnetic moments to different types of nucleon-nucleon correlations, and establish an important benchmark for further developments of theoretical calculations.

nucl-ex↗

Frequency-comb based collinear laser spectroscopy of Be for nuclear structure investigations and many-body QED tests

Absolute transition frequencies of the $2s\,^2{\rm{S}}_{1/2}$ $\rightarrow$ $2p\,^2{\rm{P}}_{1/2,3/2}$ transitions in Be$^+$ were measured with a frequency comb in stable and short-lived isotopes at ISOLDE (CERN) using collinear laser spectroscopy. Quasi-simultaneous measurements in copropagating and counterpropagating geometry were performed to become independent from acceleration voltage determinations for Doppler-shift corrections of the fast ion beam. Isotope shifts and fine structure splittings were obtained from the absolute transition frequencies with accuracies better than 1\,MHz and led to a precise determination of the nuclear charge radii of $^{7,10-12}$Be relative to the stable isotope $^9$Be. Moreover, an accurate determination of the $2p$ fine structure splitting allowed a test of high-precision bound-state QED calculations in the three-electron system. Here, we describe the laser spectroscopic method in detail, including several tests that were carried out to determine or estimate systematic uncertainties. Final values from two experimental runs at ISOLDE are presented and the results are discussed.

physics.atom-ph↗

Isotope shift of $^{40,42,44,48}$Ca in the $4s\,^2 \rm{S}_{\frac{1}{2}} \rightarrow 4p\,^2\rm{P}_{\frac{3}{2}}$ transition

We report on improved isotope shift measurements of the isotopes $^{40,42,44,48}$Ca in the $4s\,^2 \rm{S}_{\frac{1}{2}} \rightarrow 4p\,^2\rm{P}_{\frac{3}{2}}$ (D2) transition using collinear laser spectroscopy. Accurately known isotope shifts in the $4s\,^2 \rm{S}_{\frac{1}{2}} \rightarrow 4p\,^2\rm{P}_{\frac{1}{2}}$ (D1) transition were used to calibrate the ion beam energy with an uncertainty of $ΔU \approx \pm 0.25$ V. The accuracy in the D2 transition was improved by a factor of $5 - 10$. A King-plot analysis of the two transitions revealed that the field shift factor in the D2 line is about 1.8(13) % larger than in the D1 transition which is ascribed to relativistic contributions of the $4p_{1/2}$ wave function.

physics.atom-ph↗

Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy

A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE.

physics.atom-ph↗

Nuclear Charge Radii of Be-7,9,10 and the one-neutron halo nucleus Be-11

Nuclear charge radii of $^{7,9,10,11}$Be have been determined by high-precision laser spectroscopy. On-line measurements were performed with collinear laser spectroscopy in the $2s_{1/2} \to 2p_{1/2}$ transition on a beam of Be$^{+}$ ions. Collinear and anticollinear laser beams were used simultaneously and the absolute frequency determination using a frequency comb yielded an accuracy in the isotope-shift measurements of about 1 MHz. Combination with accurate calculations of the mass-dependent isotope shifts yield nuclear charge radii. The charge radius decreases from $^7$Be to $^{10}$Be and then increases for the halo nucleus $^{11}$Be. When comparing our results with predictions of {\it ab initio} nuclear structure calculations we find good agreement. Additionally, the nuclear magnetic moment of $^7$Be was determined to be $-1.3995(5)μ_{\rm N}$ and that of $^{11}$Be from a previous $β$-NMR measurement was confirmed.

nucl-ex↗

TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz

The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on the rapid neutron-capture process as well as for tests of mass models in the heavy-mass region. The laser spectroscopic measurements will yield model-independent information on nuclear ground-state properties such as nuclear moments and charge radii of neutron-rich nuclei of refractory elements far from stability. This publication describes the experimental setup as well as its present status.

nucl-ex↗