SearcharxivSearch

arXiv subjects

J. Krempel

Publications and source records attributed to J. Krempel.

At least 19 recordsLinked to original sources

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~\mu\mathrm{T} < B < 360~\mu\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex

New high-sensitivity search for neutron to mirror-neutron oscillations at the PSI UCN source

In a search for potential signals of neutron (n) to mirror-neutron (n') oscillations, a collaboration centered at the Paul Scherrer Institute (PSI) investigated the remaining parameter space claimed by anomalies with a dedicated high-sensitivity apparatus. An elaborate magnetic-field-mapping analysis and Monte Carlo simulation of the cumulative n-n' oscillation probabilities along the neutron trajectories inside the storage vessel complemented the neutron data analysis. Magnetic fields were scanned in the range 5 microT < B < 109 microT. No evidence of anomalous neutron losses was found. Consequently, new limits for the n-n' oscillation time constant were set. The parameter space, previously claimed for potential signals, has been excluded to 99.98 %.

nucl-ex

Simulation and optimization of the Active Magnetic Shield of the n2EDM experiment

The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achieved through a combination of passive shielding, provided by a magnetically shielded room (MSR), and a surrounding active field compensation system by an Active Magnetic Shield (AMS). The AMS is a feedback-controlled system of eight coils spanned on an irregular grid, designed to provide magnetic stability to the enclosed volume by actively suppressing external magnetic disturbances. It can compensate static and variable magnetic fields up to $\pm 50$ $\mu$T (homogeneous components) and $\pm 5$ $\mu$T/m (first-order gradients), suppressing them to a few $\mu$T in the sub-Hertz frequency range. We present a full finite element simulation of magnetic fields generated by the AMS in the presence of the MSR. This simulation is of sufficient accuracy to approach our measurements. We demonstrate how the simulation can be used with an example, obtaining an optimal number and placement of feedback sensors using genetic algorithms.

physics.ins-det

Measurement of the neutron incoherent scattering length of ${}^{199}$Hg using stored ultracold neutrons

We present the first direct measurement of the neutron incoherent scattering length of ${}^{199}$Hg. The measurement was performed with the Ramsey apparatus of the neutron electric dipole moment experiment located at the Paul Scherrer Institute. The incoherent scattering length $b_\textrm{i}$ was determined by investigating the pseudo-magnetic effect due to the strong interaction between the neutron spins and the nuclear spins of mercury atoms. The resulting frequency shift of the neutron Larmor precession frequency was determined for various ${}^{199}$Hg density and polarization values. The obtained value of $b_\textrm{i}= (-16.2 \pm 2.0)\,$fm agrees in magnitude with previous determinations and provides the so-far unknown sign of the quantity.

nucl-ex

Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment

We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The apparatus is able to generate a 1 $\mu$ T vertical field with a relative root mean square deviation $\sigma$ ($B_z$)/$B_z$ = 3 $\times$ $10^{-5}$ over the volume of interest, a cylinder of radius 40 cm and height 30 cm. This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 $\times$ $10^{-27}$ ecm.

physics.ins-det

Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.

physics.ins-det

A large 'Active Magnetic Shield' for a high-precision experiment

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

physics.ins-det

Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI

We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polarized ultracold neutrons stored in vacuum. The dominant systematic uncertainty resulting from magnetic-field gradients was controlled to an unprecedented level of approximately 4 pT/cm using an array of optically-pumped cesium vapor magnetometers and magnetic-field maps independently recorded using a dedicated measurement device. No signature of a theoretically predicted new interaction was found, and we set a new limit on the product of the scalar and the pseudoscalar couplings $g_sg_pλ^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) in a range of $5\,μ\text{m} < λ< 25\,\text{mm}$ for the monopole-dipole interaction. This new result confirms and improves our previous limit by a factor of 2.7 and provides the current tightest limit obtained with free neutrons.

nucl-ex

Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal

Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we report on the null result of a demonstration experiment searching for a frequency modulation of the free spin-precession signal of \magHg in a \SI{1}{\micro\tesla} magnetic field. Our search covers the axion mass range $10^{-16}~\textrm{eV} \lesssim m_a \lesssim 10^{-13}~\textrm{eV}$ and achieves a peak sensitivity to the axion-nucleon coupling of $g_{aNN} \approx 3.5 \times 10^{-6}~\textrm{GeV}^{-1}$.

nucl-ex

The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1m3 below 100pT, and a field below 600pT in the entire inner volume, up to 4\,cm to the walls. The quasi-static shielding factor at 0.01\,Hz measured with a sinusoidal 2muT peak-to-peak signal is about 100,000 in all three spatial directions and rises fast with frequency to reach 10^8 above 1Hz.

physics.ins-det

Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment

Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.

physics.ins-det

Improved search for neutron to mirror-neutron oscillations in the presence of mirror magnetic fields with a dedicated apparatus at the PSI UCN source

While the international nEDM collaboration at the Paul Scherrer Institut (PSI) took data in 2017 that covered a considerable fraction of the parameter space of claimed potential signals of hypothetical neutron ($n$) to mirror-neutron ($n'$) transitions, it could not test all claimed signal regions at various mirror magnetic fields. Therefore, a new study of $n-n'$ oscillations using stored ultracold neutrons (UCNs)is underway at PSI, considerably expanding the reach in parameter space of mirror magnetic fields ($B'$) and oscillation time constants ($τ_{nn'}$). The new apparatus is designed to test for the anomalous loss of stored ultracold neutrons as a function of an applied magnetic field. The experiment is distinguished from its predecessors by its very large storage vessel (1.47\,m$^3$), enhancing its statistical sensitivity. In a test experiment in 2020 we have demonstrated the capabilities of our apparatus. However, the full analysis of our recent data is still pending. Based on already demonstrated performance, we will reach a sensitivity to oscillation times $τ_{nn'}/\sqrt{\cos(β)}$ well above hundred seconds, with $β$ being the angle between $B'$ and the applied magnetic field $B$. The scan of $B$ will allow the finding or the comprehensive exclusion of potential signals reported in the analysis of previous experiments and suggested to be consistent with neutron to mirror-neutron oscillations.

physics.ins-det

The design of the n2EDM experiment

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.

physics.ins-det

A search for neutron to mirror-neutron oscillations

It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold neutron storage measurements have investigated neutron to mirror-neutron oscillations and imposed constraints on the theoretical parameters. Recently, further analysis of these ultracold neutron storage experiments has yielded statistically significant anomalous signals that may be interpreted as neutron to mirror-neutron oscillations, assuming nonzero mirror magnetic fields. The neutron electric dipole moment collaboration performed a dedicated search at the Paul Scherrer Institute and found no evidence of neutron to mirror-neutron oscillations. Thereby, the following new lower limits on the oscillation time were obtained: $τ_{nn'} > 352~$s at $B'=0$ (95% C.L.), $τ_{nn'} > 6~\text{s}$ for all $0.4~μ\text{T} 9~\text{s}$ for all $5.0~μ\text{T}<B'<25.4~μ\text{T}$ (95% C.L.), where $β$ is the fixed angle between the applied magnetic field and the local mirror magnetic field which is assumed to be bound to the Earth. These new constraints are the best measured so far around $B'\sim10~μ$T, and $B'\sim20~μ$T.

hep-ph

Data blinding for the nEDM experiment at PSI

Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment, as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a fake signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons of each measurement cycle. The flexible algorithm is applied twice to the data, to provide different data to various analysis teams. This gives us the option to sequentially apply various blinding offsets for separate analysis steps with independent teams. The subtle modification of the data allows us to modify the algorithm and to produce a re-blinded data set without revealing the blinding secret. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable efforts.

physics.data-an

Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment

An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.

physics.atom-ph

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

hep-ex

Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations

The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have been further analyzed by Berezhiani et al.(2009-2017), and signals, compatible with $n-n'$ oscillations in the presence of mirror magnetic fields, have been reported. The Neutron Electric Dipole Moment Collaboration based at the Paul Scherrer Institute performed a new series of experiments to further test these signals. In this paper, we describe and motivate our choice of run configurations with an optimal filling time of $29~$s, storage times of $180~$s and $380~$s, and applied magnetic fields of $10~μ$T and $20~μ$T. The choice of these run configurations ensures a reliable overlap in settings with the previous efforts and also improves the sensitivity to test the signals. We also elaborate on the technique of normalizing the neutron counts, making such a counting experiment at the ultra-cold neutron source at the Paul Scherrer Institute possible. Furthermore, the magnetic field characterization to meet the requirements of this $n-n'$ oscillation search is demonstrated. Finally, we show that this effort has a statistical sensitivity comparable to the current leading constraints for $n-n'$ oscillations.

nucl-ex