SearcharxivSearch

arXiv subjects

J. L. Bouly

Publications and source records attributed to J. L. Bouly.

15 recordsLinked to original sources

Design,fabrication and characterization of 8x9 n-type silicon pad array for sampling calorimetry

This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out using the High Granularity Calorimeter Readout Chip~(HGCROC). This paper covers the Technology Computer-Aided Design (TCAD) simulations, the fabrication process, current versus voltage (IV) and capacitance versus voltage (CV) measurements, test results with a blue LED and $^{90}$Sr beta source, and neutron radiation hardness tests. IV measurements for the detector showed that 90\% of the pads had leakage current below 10~nA at full depletion voltage. Simulations predicted a breakdown voltage of 1000~V and practical tests confirmed stable operation up to 500~V without breakdown. CV measurements in the data and the simulations gave a full depletion voltage of around 50~V at a capacitance of 35~pF. LED tests verified that all detector pads responded correctly. Additionally, the 1$\times$1 cm$^2$ pads were also tested with the neutron radiations at a fluence of $5\times10^{13}$ 1~MeV~n$_{eq}$/cm$^2$.

physics.ins-det

Beam test of n-type Silicon pad array detector at PS CERN

This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace μ}$m thick, and high-resistivity ($\sim$7 k$Ω\thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.

physics.ins-det

NIKEL_AMC: Readout electronics for the NIKA2 experiment

The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.

astro-ph.IM

Trigger and readout electronics for the STEREO experiment

The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally, for detector performance monitoring, the electronics allow on-line calibration by driving LED synchronously with the data acquisition. This paper describes the electronics requirements, architecture and the performances achieved.

physics.ins-det

MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.

physics.ins-det

MIMAC: A micro-tpc matrix for dark matter directional detection

The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.

physics.ins-det

NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires only two coaxial cables for instrumenting such a large array. The chosen solution and the performances achieved are presented in this paper.

astro-ph.IM

MIMAC: A micro-tpc matrix project for directional detection of dark matter

Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.

astro-ph.IM

Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project

Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.

astro-ph.IM

Micromegas detector developments for MIMAC

The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.

physics.ins-det

Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays

A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.

astro-ph.IM

Micromegas detector developments for Dark Matter directional detection with MIMAC

The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.

physics.ins-det

MIMAC : A micro-tpc matrix for directional detection of dark matter

Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.

astro-ph.CO

Level-1 jet trigger hardware for the ALICE electromagnetic calorimeter at LHC

The ALICE experiment at the LHC is equipped with an electromagnetic calorimeter (EMCal) designed to enhance its capabilities for jet measurement. In addition, the EMCal enables triggering on high energy jets. Based on the previous development made for the Photon Spectrometer (PHOS) level-0 trigger, a specific electronic upgrade was designed in order to allow fast triggering on high energy jets (level-1). This development was made possible by using the latest generation of FPGAs which can deal with the instantaneous incoming data rate of 26 Gbit/s and process it in less than 4 μs.

physics.ins-det

Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC

Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.

astro-ph.IM