Searcharxiv⌕ Search

arXiv subjects

J. Liu

Publications and source records attributed to J. Liu.

At least 37 records · Page 2Linked to original sources

Long-range waveguide-quantum electrodynamics with left-handed transmission lines

While engineering long-range light-matter interactions is the principal aim in waveguide-QED, ironically most of the building blocks rest on local short-range couplings, such as nearest-neighbor-coupled cavity arrays employed in canonical models. Here, we propose a waveguide-QED system with native long-range interactions, comprising a single emitter coupled to a left-handed transmission line (LHTL). Interestingly, the LHTL emulates a synthetic photonic lattice with a slow logarithmic decay of hopping amplitudes over a distance set entirely by the ratio of UV and IR cutoffs of line dispersion. Its intrinsic long-range nature manifests both in the properties of atom-photon bound and scattering states, which exhibit algebraic localization and accelerated photon propagation respectively. Using a method of 'running exponents', we develop a unified picture connecting waveguide dispersion to bound state and light front profiles obtained in the strong long-range hopping regime. These results motivate how transmission lines can enable multi-qubit information processing with tunable-range interactions.

quant-ph↗

Influence of controlled disorder on the dipolar spin ice state of Ho-based pyrochlores

Pyrochlore magnets of the form $R_2B_2$O$_7$, in which rare-earth ions on the $R$-site form a three-dimensional network of corner-sharing tetrahedra, provide a canonical setting for geometrical frustration. Ho-based pyrochlores host a dipolar spin-ice ground state, characterized by Ising moments constrained by the ice rules and elementary excitations analogous to magnetic monopoles. Here we examine how controlled chemical disorder influences this state by introducing site mixing on the non-magnetic $B$-site in two compounds. Ho$_2$GaSbO$_7$ contains only Ga$^{3+}$/Sb$^{5+}$ charge disorder, whereas Ho$_2$ScSbO$_7$ exhibits both charge and substantial size disorder arising from the large ionic-radius mismatch between Sc$^{3+}$ and Sb$^{5+}$. Although both materials retain the pyrochlore structure, neutron scattering measurements reveal a reduced correlation length for the $R/B$-site cation ordering and enhanced local structural distortions in Ho$_2$ScSbO$_7$. Despite these structural differences, bulk thermodynamic measurements and magnetic diffuse scattering demonstrate that both systems exhibit the defining signatures of a dipolar spin-ice state. Low-energy inelastic neutron spectroscopy further uncovers broad magnetic excitations that develop within the dipolar spin-ice regime, a feature absent in pristine Ho pyrochlores and indicative of disorder-induced splitting of the non-Kramers ground-state doublet. Together, these results show that controlled disorder generates tunable transverse-field-driven quantum fluctuations in Ho-based pyrochlores, although the dipolar spin-ice state is remarkably robust to this disorder.

cond-mat.str-el↗

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det↗

OJALÁ: Optimizing J-PAS Astronomy for Large-scale Analysis. A foundation model for the SED of galaxies, QSOs and stars

The advent of large-scale surveys requires efficient ML techniques to exploit the information of massive datasets. We present OJALA, a transformer-based autoregressive foundation model designed to simultaneously classify astronomical objects and infer their physical parameters using 54 narrow bands from J-PAS, combined with broad bands from the DESI Legacy Imaging Surveys and WISE. The model is trained on $\sim20$ million synthetic SEDs generated from DESI DR1 spectra. We validate OJALA using a cross-matched sample of $\sim121,000$ objects between J-PAS and DESI. The model achieves a weighted F1-score of approximately 0.9 for spectral classification (stars, galaxies, and QSOs) at $i < 21$. For galaxies, we recover photo-z with a precision of $σ_{\rm NMAD} < 0.01$, while for QSOs, the precision improves significantly at $z > 1.5$, reaching $σ_{\rm NMAD} \approx 0.006$ at $z \approx 3.5$. We demonstrate robust estimation of physical properties for galaxies, recovering stellar masses and SFR with a scatter of approximately 0.11 dex and 0.22 dex, respectively. Furthermore, the model accurately predicts EWs for major optical emission lines, allowing for the derivation of extinction-corrected H$α$ luminosities with a scatter of 0.29 dex. OJALA successfully reproduces the BPT and WHAN diagnostic diagrams, classifying SF, AGN, and passive galaxies with F1-scores typically ranging from 70% to 90% depending on the diagnostic class. For stars, the model reliably infers effective temperature and metallicity, though surface gravity remains challenging. Finally, we show the modularity of the architecture by fine-tuning the pre-trained embeddings to predict BH masses, a property not included in the primary training, recovering spectroscopic virial estimates with a precision of approximately 0.5 dex. We release the code, model weights, and a comprehensive VAC for the J-PAS EDR.

astro-ph.GA↗

Observations of the Fermi bubbles and the Galactic center excess with the DArk Matter Particle Explorer

The DArk Matter Particle Explorer (DAMPE) is a space-borne high-energy particle detector that surveys the $γ$-ray sky above$\sim 2~\rm GeV$ with a peak acceptance of $\sim 0.2~\rm m^2\,sr$. With the 102 months of data collected by DAMPE, we show that the Fermi bubbles are detected at a significance of $\sim 26σ$ and identify a GeV excess in the direction of Galactic center at $\sim 7 σ$ confidence. Both spectra and morphology are consistent with those observed by Fermi-LAT and the GeV excess component can be interpreted by the dark matter annihilation with a mass of $\sim 50$ GeV and a velocity-averaged cross section of $\sim 10^{-26}~{\rm cm^{3}~s^{-1}}$ for the $χχ\rightarrow b\bar{b}$ channel. Our results thus provide the first independent detection of these two intriguing diffuse gamma-ray sources besides Fermi-LAT.

astro-ph.HE↗

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det↗

GRB 241030A: a bright afterglow challenging forward shock emission

Gamma-Ray Burst GRB 241030A (z = 1.411) exhibited a bright afterglow (similar to GRB 221009A), detected across gamma-ray, X-ray, UV, and optical bands, providing a probe of GRB afterglow physics. We compiled multi-wavelength observations spanning from a minute to a week after the prompt emission, processing the data through a unified photometry pipeline. We analysed the observations both analytically and using Bayesian inference with two independent models. Our models assume that the afterglow emission arises from the strong forward shock of a laterally structured jet, with possible contributions from synchrotron self-Compton (SSC) scatterings. Our models reproduce X-ray to optical data, favouring a jet propagating into a constant-density interstellar medium, with a viewing angle within the jet core. However, both analyses require parameter values that are extreme compared to expectations from standard theory. In particular, our results imply extremely energetic jets despite regular prompt energy, leading to a very inefficient prompt emission. Furthermore, the jets are inefficient at accelerating particles, with low electron and magnetic energy fractions, leading to significant SSC emission. Our analyses indicate that the jets have large opening angles and propagate in high-density media. If the afterglow is indeed powered by radiation emitted behind a strong forward shock, our results place GRB 241030A within a sub-class of GRBs characterised by extreme kinetic energies, large jet opening angles, and very low prompt emission efficiencies, with strong SSC radiation. These predictions are difficult to reconcile with typical expectations from other GRBs. We therefore suggest that the afterglow of GRB 241030A is not solely powered by forward shock emission.

astro-ph.HE↗

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex↗

Response of wavelength-shifting and scintillating-wavelength-shifting fibers to ionizing radiation

We report results of characterizing the response and light transport of wavelength-shifting (WLS) and scintillating-wavelength-shifting (Sci-WLS) fibers under irradiation by radioactive $α$, $β$, and $γ$ sources. Light yield and light transmission were measured for the WLS fiber BCF-91A from Saint-Gobain and for a new Sci-WLS fiber EJ-160 from Eljen Technology. The two variants with different fluor mixtures, EJ-160I and EJ-160II, exhibited approximately five and seven times higher light yield than BCF-91A, respectively, while their attenuation lengths were 3.80\,m for BCF-91A, 4.00\,m for EJ-160I, and 2.50\,m for EJ-160II.

physics.ins-det↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

hep-ex↗

Multi-epoch afterglow rebrightenings in GRB 250129A: Evidence for successive shock interactions

Most long gamma-ray bursts (GRBs) exhibit afterglows broadly consistent with external forward-shock emission, typically described by smooth broken power-law decays in the multiband light curve. However, a minority of well-sampled GRBs deviate from this behavior, including GRB 250129A. This object shows multiple late-time rebrightenings at X-ray and optical wavelengths. Rebrightenings are often attributed to energy injection from prolonged central engine activity, refreshed shocks from delayed shell collisions, density jumps in the ambient medium, or angular jet structure and viewing-angle effects. After analysing the prompt emission observed in gamma-rays and the near-infrared, we investigate the origin of X-ray and optical flaring episodes in GRB 250129A. Physical processes in the afterglow light curves were investigated using methods ranging from empirical fitting to Bayesian inference. The well-sampled flares and the connection between the prompt and afterglow emission allow us to test the consistency of the fireball model and alternative scenarios. Conducting the prompt and time-resolved analyses, we obtained an isotropic-equivalent energy of E_iso,gamma = (1.35 +/- 0.12) x 10^53 erg. By modeling the afterglow using an agnostic Bayesian framework (NMMA), we rule out both a single external-shock evolution and a one-time energy-injection scenario. Numerical calculations show that the rebrightening episodes are consistent with refreshed shocks from delayed collisions between relativistic shells. Based on the consistency between our analyses of the prompt and afterglow GRB 250129A data, we find that two statistically significant rebrightening episodes occur within 1.1 days post trigger and can be explained by a sequence of refreshed shocks. Temporally and spectrally rich GRB datasets such as the one presented in this work, provide a powerful means to test current modeling frameworks.

astro-ph.HE↗

Precision measurement of neutrino oscillation parameters with 10 years of data from the NOvA experiment

This Letter reports measurements of muon-neutrino disappearance and electron-neutrino appearance and the corresponding antineutrino processes between the two NOvA detectors in the NuMI neutrino beam. These measurements use a dataset with double the neutrino mode beam exposure that was previously analyzed, along with improved simulation and analysis techniques. A joint fit to these samples in the three-flavor paradigm results in the most precise single-experiment constraint on the atmospheric neutrino mass splitting, $Δm^2_{32}= 2.431^{+0.036}_{-0.034} (-2.479^{+0.036}_{-0.036}) \times 10^{-3}~\mathrm{eV}^2$ if the mass ordering is normal (inverted). In both orderings, a region close to maximal mixing with $\sin^2 θ_{23}=0.55^{+0.02}_{-0.06}$ is preferred. The NOvA data show a mild preference for the normal mass ordering with a Bayes factor of 2.4 (corresponding to 70% of the posterior probability), indicating that the normal ordering is 2.4 times more probable than the inverted ordering. When incorporating a 2D $Δm^2_{32}\text{--}\sin^2 2θ_{13}$ constraint based on Daya Bay data, this preference strengthens to a Bayes factor of 6.6 (87%).

hep-ex↗

Search for Light-Mass Fractionally Charged Particles in Space with DAMPE Experiment

Free Fractionally Charged Particles (FCPs) are predicted by some theories beyond or extended to the standard model. FCPs have been widely searched for by underground and space-based experiments based on the assumption of heavy lepton-like particles. However, there is a paucity of research focusing on light-mass FCPs (LFCPs) in the sub-MeV mass range. In this work, we report the LFCPs in primary high energy cosmic rays, based on observational data from the Dark Matter Particle Explorer (DAMPE) satellite. This study utilized ten years on-orbit data of DAMPE to search for LFCPs with a charge of $\frac{2}{3}~e$. No LFCP candidate was observed. Upper flux limit of LFCPs with a mass of 0.511 MeV$/c^{2}$ and a charge of $\frac{2}{3}~e$ is determined to be $\rm 5.0 \times 10^{-11}\,cm^{-2}sr^{-1}s^{-1}$ at the $\rm 90\%$ confidence level.

astro-ph.HE↗

Diverse properties of electron Forbush decreases revealed by the Dark Matter Particle Explorer

The Forbush decrease (FD) of cosmic rays is an important probe of the interplanetary environment disturbed by solar activities. In this work, we study the properties of 8 FDs electrons (including positrons) between 2 GeV and 20 GeV from January, 2016 to March, 2024, with the Dark Matter Particle Explorer. The maximum decrease amplitudes of these events are about 30% - 15%, and the amplitudes reduce with energy. The recovery time of these events shows diverse behaviors of their energy-dependence. Some of them show strong energy-dependence, while some have a nearly constant recovery time. It has been shown that such diverse behaviors could be related with the geometry of the disturbed regions of the interplanetary space by coronal mass ejections (CME), represented by the combined effect of the CME velocity, angular spread, and ejection direction.

astro-ph.HE↗

Modal Energy for Power System Analysis: Definitions and Requirements

Modal energy provides information complementary to and based on conventional eigenvalues and participation factors for power system modal analysis. However, modal energy definition is not unique. This letter clarifies the definitions and applicability of mainstream modal energy approaches, focusing on their mappings to eigenvalues and to the total system energy. It is shown that these mappings hold only under restrictive conditions, notably system normality, which limits their applicability in inverter-dominated power systems.

eess.SY↗

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex↗

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det↗

Multimode Objective Lens for Momentum Microscopy and XPEEM: Experiments

A new type of objective lens has recently been proposed for use in X-ray photoemission electron microscopes (XPEEMs) and momentum microscopes. Adding a ring electrode concentric with the extractor allows the field in the gap between the sample and the extractor to be shaped. Forming a lens field in this gap reduces the field strength at the sample by up to an order of magnitude. This mitigates the risk of field emission, particularly for cleaved samples with sharp edges. A retarding field can redirect all slow electrons, thus eliminating the primary contribution to the space-charge interaction. Here we present the first experimental investigation of the new lens, examining its performance at photon energies ranging from the extreme ultraviolet produced by a high-harmonic generation (HHG)-based source to soft and hard X-rays at two synchrotron facilities. The gap lens in a region without electrodes enables large working distances up to 23 mm. Reduced aberrations allow for larger fields of view in both k-space and real-space imaging, with resolutions comparable to those of conventional cathode lenses. However, field strengths are an order of magnitude smaller. The zero-field mode enables the study of 3D structured objects and is therefore beneficial for small cleaved samples as well as for operando devices involving top electrodes. The repeller mode reduces space-charge effects, but results in a smaller k-field diameter. This reduction ranges from 10% at hard X-ray energies to 50% in the XUV range. The usable energy interval is also reduced by a factor of two. In time-of-flight XPEEM mode the raw data show a resolution of 250 nm, which can be improved to better than 100 nm through data processing.

cond-mat.mtrl-sci↗